BTEX ZB1 100x0.25x0.5
GC Conditions
Column
Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea
Part No
7MG-G001-17
Phase Name
ZB-1
Injection
Split 20:1 @ 225°C
Carrier Gas
Constant Flow Helium, 1.4 mL/min
Detection
Flame Ionization (FID) @ (300°C)
Detection Info
Sample Notes
Portion of BTEX solution chromatogram showing near full resolution of para- and meta-xylene.
Order Items Used in This Application
- 1. Ethylbenzene
- 2. m-Xylene
- 3. p-Xylene
- 4. o-Xylene
-OEChem-06211003152D<br><br> 18 18 0 0 0 0 0 0 0999 V2000<br> 2.8660 1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.6540 1.8326 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.2554 1.1423 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 0.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 0.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0420 1.2131 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 2.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4220 2.2869 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -1.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -1.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -2.3700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 2 1 0 0 0 0<br> 1 5 1 0 0 0 0<br> 1 9 1 0 0 0 0<br> 1 10 1 0 0 0 0<br> 2 3 2 0 0 0 0<br> 2 4 1 0 0 0 0<br> 3 6 1 0 0 0 0<br> 3 11 1 0 0 0 0<br> 4 7 2 0 0 0 0<br> 4 12 1 0 0 0 0<br> 5 13 1 0 0 0 0<br> 5 14 1 0 0 0 0<br> 5 15 1 0 0 0 0<br> 6 8 2 0 0 0 0<br> 6 16 1 0 0 0 0<br> 7 8 1 0 0 0 0<br> 7 17 1 0 0 0 0<br> 8 18 1 0 0 0 0<br>M END
Compound Name
Ethylbenzene
CID
7500
Molecular Formula
C8H10
Molecular Weight
106
Similar Applications
Application Specific
ASTM 6730 on ZB-PONA 100m x 0.25mm x 0.5um with ZB-PONA tuning 5m x 0.25mm x 1.0mm
Zebron ZB-DHA-PONA, GC Cap. Column 100m x 0.25mm x 0.5µm, Ea
25558
Application Specific
Aromatics Marker Standards on ZB-DHA-PONA 100m x 0.25mm x 0.5um
Zebron ZB-DHA-PONA, GC Cap. Column 100m x 0.25mm x 0.5µm, Ea
25309
Standard
Bioethanol by MSD on a ZB-1
Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea
16657
Application Specific
Bioethanol by MSD on ZB-Bioethanol
Zebron ZB-Bioethanol, GC Cap. Column 30 m x 0.25 mm x 1.00 µm, Ea
16654
Application Specific
BTEXs on ZB-MR1
Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16254
Application Specific
BTEXs on ZB-MR2
Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.25 mm x 0.20 µm, Ea
16253
Standard
ASTM Method D3798: Analysis of p-Xylene on ZB-WAX
Zebron ZB-WAX, GC Cap. Column 30 m x 0.25 mm x 0.50 µm, Ea
16219
Standard
ASTM Method D3798: Analysis of p-Xylene on ZB-WAX
Zebron ZB-WAX, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea
16218
Standard
ASTM Method D5060: Determining Impurities in High Purity Ethylbenzene on ZB-FFAP
Zebron ZB-FFAP, GC Cap. Column 50 m x 0.32 mm x 0.50 µm, Ea
16145
Standard
ASTM Method D2306-96: Universal Aromatic Solvent Analysis on ZB-WAX
Zebron ZB-WAX, GC Cap. Column 60 m x 0.32 mm x 0.50 µm, Ea
16141
Improved Performance
ASTM Method D5135-95: Solvent Analysis on ZB-WAXplus
Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16140
Standard
ASTM Method D5135-95: Solvent Analysis on ZB-WAX
Zebron ZB-WAX, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16139
Standard
EPA Method 8260 - Volatile Organic Analysis on Zebron ZB-624 20m x 0.18mm x 1.00um
Zebron ZB-624, GC Cap. Column 20 m x 0.18 mm x 1.00 µm, Ea
15866
Improved Performance
p-Xylene Purity on ZB-WAX Plus 30m x 0.53mm x 1.00um
Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.53 mm x 1.00 µm, Ea
15865
Improved Performance
p-Xylene Purity on ZB-WAX Plus 30x0.25x0.25
Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
15810
Standard
EPA Method 8260B: Volatile Organic Analysis on ZB-624
Zebron ZB-624, GC Cap. Column 20 m x 0.18 mm x 1.00 µm, Ea
15697
Standard
p-Xylene Purity on ZB-WAX
Zebron ZB-WAX, GC Cap. Column 30 m x 0.53 mm x 1.00 µm, Ea
14941
Standard
Unleaded Gasoline - Pure on ZB-1
Zebron ZB-1, GC Cap. Column 60 m x 0.25 mm x 1.00 µm, Ea
14940
Standard
BTEX ZB-50 30x0.32x0.5
Zebron ZB-50, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea
14903
Standard
BTEX ZB5 30x0.32x0.25
Zebron ZB-5, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
14902
Standard
BTEX ZB1 100x0.25x0.5
Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea
14901
Standard
BTEX in Under Six Minutes on ZB-WAX
Zebron ZB-WAX, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea
14895
Standard
PONA: Naphtha on ZB-1
Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea
14804
Standard
PONA: Retention Markers on ZB-1
Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea
14803
Standard
PONA: FCC on ZB-1
Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea
14802
Standard
PONA: Blended Fuel 1 on ZB-1
Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea
14801
Standard
PONA: Alkylate Fraction on ZB-1
Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea
14800
Standard
EPA Method 8260: Volatile Organics on ZB-624
Zebron ZB-624, GC Cap. Column 60 m x 0.25 mm x 1.40 µm, Ea
14783
Standard
Volatile Organics by GC/MS (EPA Method 8260B)
Zebron ZB-624, GC Cap. Column 60 m x 0.53 mm x 3.00 µm, Ea
14441
Standard
EPA Method 624 CLP
Zebron ZB-624, GC Cap. Column 30 m x 0.53 mm x 3.00 µm, Ea
14323
Standard
Gasoline Range Organics
Zebron ZB-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
1265