Selectivity of Acidic, Neutral and Basic Analytes at pH4.0

Selectivity of Acidic, Neutral and Basic Analytes at pH4.0
LC Conditions
Column

Gemini 5 µm C18 110 Å, LC Column 150 x 4.6 mm, Ea

Brand

Gemini

Part No

00F-4435-E0

Phase Name

C18

Elution Type

Isocratic

Mobile Phase

A: 20mM Ammonium formate, pH4.0

B: ACN

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

50

50

Flow Rate

1.00 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Gemini C18 4 x 3.0mm, 10/Pk Part No.: AJ0-7597 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Gemini 5 µm C18 110 Å, LC Column 150 x 4.6 mm, Ea
00F-4435-E0

Gemini 5 µm C18 110 Å, LC Column 150 x 4.6 mm, Ea

View Product

  • 1. Chlorpropamide
  • 2. Butyl paraben
  • 3. Lidocaine
  • 4. Triprolidine
  • 5. Dextromethorphan
-OEChem-06211003152D<br><br> 30 30  0     0  0  0  0  0  0999 V2000<br>    3.0000   -4.2500    0.0000 Cl  0  0  0  0  0  0  0  0  0  0  0  0<br>    3.0000   -0.2500    0.0000 S   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.0000   -0.2500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -0.2500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.7320    0.7500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.0000    0.7500    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.8660    2.2500    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.7320    2.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.0000   -1.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.7320    3.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.8660    1.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.8660   -1.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.1340   -1.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.5981    4.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.8660   -2.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.1340   -2.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.0000   -3.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.9441    2.1674    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.3426    2.8577    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5200    4.3326    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.1215    3.6423    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.4631    1.0600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.3291    2.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.4030   -1.4400    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.5970   -1.4400    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.9081    3.7131    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.1350    4.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.2881    4.7869    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.4030   -3.0600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.5970   -3.0600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1 17  1  0  0  0  0<br>  2  3  2  0  0  0  0<br>  2  4  2  0  0  0  0<br>  2  6  1  0  0  0  0<br>  2  9  1  0  0  0  0<br>  5 11  2  0  0  0  0<br>  6 11  1  0  0  0  0<br>  6 22  1  0  0  0  0<br>  7  8  1  0  0  0  0<br>  7 11  1  0  0  0  0<br>  7 23  1  0  0  0  0<br>  8 10  1  0  0  0  0<br>  8 18  1  0  0  0  0<br>  8 19  1  0  0  0  0<br>  9 12  2  0  0  0  0<br>  9 13  1  0  0  0  0<br> 10 14  1  0  0  0  0<br> 10 20  1  0  0  0  0<br> 10 21  1  0  0  0  0<br> 12 15  1  0  0  0  0<br> 12 24  1  0  0  0  0<br> 13 16  2  0  0  0  0<br> 13 25  1  0  0  0  0<br> 14 26  1  0  0  0  0<br> 14 27  1  0  0  0  0<br> 14 28  1  0  0  0  0<br> 15 17  2  0  0  0  0<br> 15 29  1  0  0  0  0<br> 16 17  1  0  0  0  0<br> 16 30  1  0  0  0  0<br>M  END
Compound Name

Chlorpropamide

CID

2727

Molecular Formula

C10H13ClN2O3S

Molecular Weight

276

No. Hydrogen Bond Acceptors

3

No. Hydrogen Bond Donors

2