Patulin analysis using Gemini

Patulin analysis using Gemini
LC Conditions
Column

Gemini 5 µm C18 110 Å, LC Column 150 x 3 mm, Ea

Brand

Gemini

Part No

00F-4435-Y0

Phase Name

C18

Elution Type

Isocratic

Mobile Phase

A: Water

B: Acetonitrile

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

90

10

Flow Rate

0.50 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Gemini C18 4 x 2.0mm, 10/Pk Part No.: AJ0-7596 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Gemini 5 µm C18 110 Å, LC Column 150 x 3 mm, Ea
00F-4435-Y0

Gemini 5 µm C18 110 Å, LC Column 150 x 3 mm, Ea

View Product

  • 1. Patulin
-OEChem-06211003152D<br><br> 17 18  0     1  0  0  0  0  0999 V2000<br>    2.0000   -0.1550    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.6783   -1.4597    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    1.3450    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.2619   -0.6550    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -0.1550    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    0.3450    0.0000 C   0  0  3  0  0  0  0  0  0  0  0  0<br>    3.7320   -1.1550    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -1.1550    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -1.6550    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.6783    0.1497    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.2619   -0.6550    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4030    0.6550    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.3894   -1.0473    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.7880   -1.7376    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -2.2750    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.8709    0.7391    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3291    1.6550    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  6  1  0  0  0  0<br>  1  8  1  0  0  0  0<br>  2  7  1  0  0  0  0<br>  2 11  1  0  0  0  0<br>  3  6  1  0  0  0  0<br>  3 17  1  0  0  0  0<br>  4 11  2  0  0  0  0<br>  5  6  1  0  0  0  0<br>  5  7  1  0  0  0  0<br>  5 10  2  0  0  0  0<br>  6 12  1  0  0  0  0<br>  7  9  2  0  0  0  0<br>  8  9  1  0  0  0  0<br>  8 13  1  0  0  0  0<br>  8 14  1  0  0  0  0<br>  9 15  1  0  0  0  0<br> 10 11  1  0  0  0  0<br> 10 16  1  0  0  0  0<br>M  END
Compound Name

Patulin

CID

4696

Molecular Formula

C7H6O4

Molecular Weight

154

No. Hydrogen Bond Acceptors

4

No. Hydrogen Bond Donors

1

Similar Applications

Reversed Phase

Mycotoxins in negative mode using Luna Omega Polar C18 50x2.1mm

Luna Omega 1.6µm Polar C18 100Å, LC Column 50 x 2.1 mm, EA

23574

Reversed Phase

Multi-Class Screening of 243 Mycotoxins by LC/MS/MS

Gemini 5 µm C18 110 Å, LC Column 150 x 4.6 mm, Ea

20027