Flavonol and Xanthone Glycosides from Mango Peels
LC Conditions
Column
Synergi 4 µm Hydro-RP 80 Å, LC Column 150 x 3 mm, Ea
Brand
Synergi
Part No
00F-4375-Y0
Phase Name
Hydro-RP
Elution Type
Gradient
Mobile Phase
A: 2% (v/v) acetic acid in water
B: 0.5% acetic acid in water and acetonitrile (50:50, v/v)
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
2
15
75
25
3
50
70
30
4
60
20
80
5
65
0
100
6
65.5
100
0
Flow Rate
0.60 mL/min
Temperature
25°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, AQ C18 4 x 2.0mm, 10/Pk Part No.: AJ0-4286 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Mangiferin
- 2. Isomangiferin
- 3. Mangiferin gallate
- 4. Isomangiferin gallate
- 5. Quercetin 3-O-diglycoside
- 6. Quercetin 3-O-galactoside
- 7. Quercetin 3-O-glucoside
- 8. Quercetin 3-O-xyloside
- 9. Quercetin 3-O-arabinopyranoside
- 10. Quercetin 3-O-arabinofuranoside
- 11. Quercetin 3-O-rhamnoside
- 12. Kaempferol 3-O-glucoside
- 13. Rhamnetin-hexoside
- 14. Quercetin
Similar Applications