Hydrocortisone (Synergi 4µm Fusion-RP)
LC Conditions
Column
Synergi 4 µm Fusion-RP 80 Å, LC Column 150 x 4.6 mm, Ea
Brand
Synergi
Part No
00F-4424-E0
Phase Name
Fusion-RP
Elution Type
Isocratic
Mobile Phase
A: Water
B: Acetonitrile
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
75
25
Flow Rate
1.50 mL/min
Temperature
25°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (25°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Fusion-RP 4 x 3.0mm, 10/Pk Part No.: AJ0-7557 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Hydrocortisone
- 2. Cortisone 21-acetate
-OEChem-06211003152D<br><br> 56 59 0 1 0 0 0 0 0999 V2000<br> 8.0319 1.8625 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7950 1.1062 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.0465 2.4920 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.8722 1.6754 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -2.4462 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3931 0.6062 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 7.3931 -0.3938 0.0000 C 0 0 2 0 0 0 0 0 0 0 0 0<br> 6.5271 -0.8938 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 5.6610 -0.3938 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 8.3393 0.9109 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 6.5271 1.1062 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7510 -0.9007 0.0000 C 0 0 2 0 0 0 0 0 0 0 0 0<br> 5.6610 0.6062 0.0000 C 0 0 2 0 0 0 0 0 0 0 0 0<br> 8.3393 -0.6986 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.9229 0.1062 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5431 -1.9353 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3931 1.6062 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7430 -1.9423 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6451 -2.4631 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.8242 -0.3366 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7587 0.0993 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.1493 1.4973 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8763 -0.8645 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.8076 -2.4920 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8680 -1.9495 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.0622 1.0890 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.4830 -1.2390 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.2664 -1.3131 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3972 0.0312 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.9256 1.5811 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.1285 1.5811 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6610 1.2262 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0883 -1.2655 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.8767 -1.0078 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.3838 -0.3086 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.3838 0.5209 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7612 -2.5157 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1523 -1.8198 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0131 1.6062 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3931 2.2262 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7731 1.6062 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2478 -2.9390 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0460 -2.9360 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2324 0.1301 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4343 0.1455 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.3787 0.0945 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7635 0.7193 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.1388 0.1041 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.4476 2.3225 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.6718 -0.2792 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.2647 -0.9659 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7950 1.7262 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.8100 -3.1120 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.7146 0.5756 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.5074 0.6575 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 11.4382 1.4222 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 10 1 1 6 0 0 0<br> 1 49 1 0 0 0 0<br> 13 2 1 1 0 0 0<br> 2 52 1 0 0 0 0<br> 3 22 2 0 0 0 0<br> 4 26 1 0 0 0 0<br> 4 56 1 0 0 0 0<br> 5 25 2 0 0 0 0<br> 6 7 1 0 0 0 0<br> 6 10 1 0 0 0 0<br> 6 11 1 0 0 0 0<br> 6 17 1 1 0 0 0<br> 7 8 1 0 0 0 0<br> 7 14 1 0 0 0 0<br> 7 27 1 6 0 0 0<br> 8 9 1 0 0 0 0<br> 8 16 1 0 0 0 0<br> 8 28 1 1 0 0 0<br> 9 12 1 0 0 0 0<br> 9 13 1 0 0 0 0<br> 9 29 1 6 0 0 0<br> 10 15 1 0 0 0 0<br> 10 22 1 0 0 0 0<br> 11 13 1 0 0 0 0<br> 11 30 1 0 0 0 0<br> 11 31 1 0 0 0 0<br> 12 18 1 0 0 0 0<br> 12 20 1 0 0 0 0<br> 12 21 1 1 0 0 0<br> 13 32 1 0 0 0 0<br> 14 15 1 0 0 0 0<br> 14 33 1 0 0 0 0<br> 14 34 1 0 0 0 0<br> 15 35 1 0 0 0 0<br> 15 36 1 0 0 0 0<br> 16 19 1 0 0 0 0<br> 16 37 1 0 0 0 0<br> 16 38 1 0 0 0 0<br> 17 39 1 0 0 0 0<br> 17 40 1 0 0 0 0<br> 17 41 1 0 0 0 0<br> 18 19 1 0 0 0 0<br> 18 24 2 0 0 0 0<br> 19 42 1 0 0 0 0<br> 19 43 1 0 0 0 0<br> 20 23 1 0 0 0 0<br> 20 44 1 0 0 0 0<br> 20 45 1 0 0 0 0<br> 21 46 1 0 0 0 0<br> 21 47 1 0 0 0 0<br> 21 48 1 0 0 0 0<br> 22 26 1 0 0 0 0<br> 23 25 1 0 0 0 0<br> 23 50 1 0 0 0 0<br> 23 51 1 0 0 0 0<br> 24 25 1 0 0 0 0<br> 24 53 1 0 0 0 0<br> 26 54 1 0 0 0 0<br> 26 55 1 0 0 0 0<br>M END
Compound Name
Hydrocortisone
CID
5754
Molecular Formula
C21H30O5
Molecular Weight
362
No. Hydrogen Bond Acceptors
5
No. Hydrogen Bond Donors
3
Similar Applications
Steroid mix on Waters XBridge 3.5 µm C18 150x4.6mm (Batch 3) using Agilent 1260 UHPLC System
26515
Steroid mix on Waters XBridge 3.5 µm C18 150x4.6mm (Batch 2) using Agilent 1260 UHPLC System
26514
Steroid mix on Waters XBridge 3.5 µm C18 150x4.6mm (Batch
- using Agilent 1260 UHPLC System
26513
Steroid mix on Agilent Zorbax SB-C18 3.5 µm 150x4.6mm (Batch 3) using Agilent 1260 UHPLC System
26512
Steroid mix on Agilent Zorbax SB-C18 3.5µm 150x4.6mm (Batch 2) using Agilent 1260 UHPLC System
26511
Steroid mix on Agilent Zorbax SB-C18 3.5 µm 150x4.6mm (Batch 1) using Agilent 1260 UHPLC System
26510
Reversed Phase
Steroid mix on Luna Omega 3 µm C18 150x4.6mm (Batch 3) using Agilent 1260 UHPLC System
Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
26509
Reversed Phase
Steroid mix on Luna Omega 3 µm C18 150x4.6mm (Batch 2) using Agilent 1260 UHPLC System
Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
26508
Reversed Phase
Steroid mix on Luna Omega 3 µm C18 150x4.6mm (Batch 1) using Agilent 1260 UHPLC System
Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
26503
Reversed Phase
Steroid 8 Mix on Luna Omega 1.6u C18 50x2.1mm
Luna Omega 1.6µm C18 100Å, LC Column 50 x 2.1 mm, EA
23486
Reversed Phase
Steroid Panel on Kinetex 2.6u Biphenyl 50x3.0
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22145
Reversed Phase
Cortisone and Cortisol on Kinetex C18, 2.6um
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
22094
Reversed Phase
Steroid panel using Kinetex 2.6u Biphenyl 50x2.1mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea
21999
Reversed Phase
Steroids on Kinetex Biphenyl 2.6µm 50x4.6mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 4.6 mm, Ea
21966
Reversed Phase
Separation of Steroids Mixture on Kinetex 5u C18 for Scalability
Kinetex 5 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
20837
Reversed Phase
Separation of Steroids Mixture on Kinetex 2.6u C18 for Scalability
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
20836
Reversed Phase
Separation of Steroids Mixture on Kinetex 1.7u C18 for Scalability
Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
20835
Steroids on Onyx C18 100 x 4.6 mm - CH3CN Modifier
19996
Steroids on Onyx C18 100 x 4.6 mm - MeOH Modifier
19994
Reversed Phase
Steroids Mix on Kinetex 2.6µ C18
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 4.6 mm, Ea
19992
Reversed Phase
Steroids Mix on Kinetex 2.6µ Phenyl-Hexyl
Kinetex 2.6 µm Phenyl-Hexyl 100 Å, LC Column 50 x 4.6 mm, Ea
19991
Reversed Phase
8 Steroid Mix on Kinetex 1.7u XB-C18 150x2.1mm using Acqutiy UPLC System
Kinetex 1.7 µm XB-C18 100 Å, LC Column 150 x 2.1 mm, Ea
19804
5 Steroid Mix spiked in Human Urine on Zorbax 3.5u SB-C18 150x4.60mm @ 1.200mL/min
19654
Reversed Phase
5 Steroid Mix spiked in Human Urine on Kinetex 2.6u XB-C18 75x4.60mm @ 2.00mL/min
Kinetex 2.6 µm XB-C18 100 Å, LC Column 75 x 4.6 mm, Ea
19653
Reversed Phase
5 Steroid Mix spiked in Human Urine on Kinetex 2.6u XB-C18 150x4.60mm @ 1.200mL/min
Kinetex 2.6 µm XB-C18 100 Å, LC Column 150 x 4.6 mm, Ea
19652
Reversed Phase
Steroids Mix using Kinetex 2.6µm PFP, 50x2.1mm
Kinetex 2.6 µm PFP 100 Å, LC Column 50 x 2.1 mm, Ea
19528
Reversed Phase
Steroids Mix using Kinetex 2.6µm C8, 50x2.1mm
Kinetex 2.6 µm C8 100 Å, LC Column 50 x 2.1 mm, Ea
19526
Reversed Phase
Steroids Mix using Kinetex 2.6µm C18 50x2.1mm
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19488
Reversed Phase
Steroids Mix using Kinetex 2.6u XB-C18, 50x2.1mm
Kinetex 2.6 µm XB-C18 100 Å, LC Column 50 x 2.1 mm, Ea
19487
Reversed Phase
Steroid Mixture on Kinetex PFP
Kinetex 2.6 µm PFP 100 Å, LC Column 50 x 2.1 mm, Ea
19480
Reversed Phase
Steroid Mixture on Kinetex 2.6µm C8 50x2.1mm ID
Kinetex 2.6 µm C8 100 Å, LC Column 50 x 2.1 mm, Ea
19479
Reversed Phase
Steroid Mixture on Kinetex XB-C18 50x2.1mm ID
Kinetex 2.6 µm XB-C18 100 Å, LC Column 50 x 2.1 mm, Ea
19478
Reversed Phase
Steroid Mixture on Kinetex C18
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19477
Reversed Phase
Steroids on Luna 3µm PFP(2) 50 x 2mm ID (in acetonitrile)
Luna 3 µm PFP(2) 100 Å, LC Column 50 x 2 mm, Ea
18508
Reversed Phase
Steroids on Kinetex 2.6µm C18 50 x 2.1mm ID (in acetonitrile)
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
18507
Reversed Phase
Steroids on Kinetex PFP 1.7µm 50 x 2.1mm ID (in acetonitrile)
Kinetex 1.7 µm PFP 100 Å, LC Column 50 x 2.1 mm, Ea
18506
Reversed Phase
Steroids on Kinetex 2.6µm PFP 50 x 2.1mm ID (in acetonitrile)
Kinetex 2.6 µm PFP 100 Å, LC Column 50 x 2.1 mm, Ea
18505
Reversed Phase
Steroid Mix (11) on Luna 5um PFP(2)
Luna 5 µm PFP(2) 100 Å, LC Column 150 x 4.6 mm, Ea
16291
Reversed Phase
Steroid Mix (11) on Luna 3um PFP(2)
Luna 3 µm PFP(2) 100 Å, LC Column 150 x 4.6 mm, Ea
16290
Reversed Phase
Steroids on Hyperclone 5u C8
HyperClone 5 µm MOS (C8) 120 Å, LC Column 150 x 4.6 mm, Ea
14689
Reversed Phase
Steroids
Luna 5 µm Phenyl-Hexyl 100 Å, LC Column 150 x 4.6 mm, Ea
14514
Reversed Phase
Steroids
Luna 5 µm C8(2) 100 Å, LC Column 150 x 4.6 mm, Ea
14511
Reversed Phase
Steroids
Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea
14350
Normal Phase
Steroids (2) on Luna Amino
Luna 5 µm NH2 100 Å, LC Column 150 x 4.6 mm, Ea
14300
Normal Phase
Corticosteroids
Luna 3 µm CN 100 Å, LC Column 100 x 4.6 mm, Ea
12946
Reversed Phase
Steroids
Synergi 4 µm Max-RP 80 Å, LC Column 50 x 4.6 mm, Ea
12480
Reversed Phase
Hydrocortisone Cream - USP Acceptable Modified Method
Luna 3 µm C18(2) 100 Å, LC Column 100 x 4.6 mm, Ea
8714
Normal Phase
Corticosteroids - Sphereclone vs. Spherisorb Comparison
SphereClone 5 µm NH2 80 Å, LC Column 250 x 4.6 mm, Ea
5596
Reversed Phase
Hydrocortisone Cream - USP Method
Luna 5 µm C18(2) 100 Å, LC Column 250 x 4.6 mm, Ea
3271
Reversed Phase
Steroids
Luna 3 µm C8(2) 100 Å, LC Column 75 x 4.6 mm, Ea
1212
Reversed Phase
Steroids
Luna 3 µm C18(2) 100 Å, LC Column 75 x 4.6 mm, Ea
1198
Reversed Phase
Steroids
Luna 3 µm C8(2) 100 Å, LC Column 75 x 4.6 mm, Ea
1196
Reversed Phase
Steroids
Luna 5 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
1185