Protein Precipatation vs. Ion Suppression of Medium Polar Drugs on strata Impact Square Well Plate

Protein Precipatation vs. Ion Suppression of Medium Polar Drugs on strata Impact Square Well Plate
LC Conditions
Column

Gemini 3 µm C18 110 Å, LC Column 150 x 3 mm, Ea

Brand

Gemini

Part No

00F-4439-Y0

Phase Name

C18

Elution Type

Gradient

Mobile Phase

A: 0.1% Formic acid/Water

B: 0.08% Formic acid/Acetonitrile

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

90

10

2

5

50

50

3

7

50

50

Flow Rate

0.50 mL/min

Temperature

22°C

Detection

Mass Spectrometer (MS) @ (22°C)

Detection Info
Sample Notes

Protein Precipitation Protocol: Phase: Strata Impact Square Well Plate, 2 mL (CEO-7565) 1. Dispense 300 uL acetonitrile into each well using an automatic pipettor. 2. Place the protein precipitation plate onto a suitable 96-well vacuum manifold . Make sure that a 96-well collection plate is positioned inside the manifold to collect the filtrate. 3. Dispense 100 uL of Porcine plasma into each well ( acetonitrile:plasma = 3:1). Let it stand for 2 mins (no vortex /mixing required). 4. Apply 5-10" of mercury for 30-40 secs. 5. Collect the filtrate and blow down to dryness under slow stream of nitrogen @ 40 deg. C. 6. Reconstitute with 100 uL of mobile phase containing 10.0 ng of analye. Note: For ion suppression or enhancement estimation, a set of 4 blank (100 uL of water instead of plasma) was run in parallel. Observation: Filtrate looked very clean and clear Results: Analyte logP m/z % Variation Effect 1. Pindolol 1.75 249 15% Suppression 2. Metoprolol 1.88 268 13% Suppression

Order Items Used in This Application

Gemini 3 µm C18 110 Å, LC Column 150 x 3 mm, Ea
00F-4439-Y0

Gemini 3 µm C18 110 Å, LC Column 150 x 3 mm, Ea

View Product

  • 1. Pindolol
  • 2. Metoprolol
-OEChem-06211003152D<br><br> 38 39  0     1  0  0  0  0  0999 V2000<br>    5.4641   -0.5530    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641    1.4470    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    2.4470    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.2764   -3.3577    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    0.9470    0.0000 C   0  0  3  0  0  0  0  0  0  0  0  0<br>    3.7320    1.4470    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    2.9470    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -0.0530    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3301   -2.0530    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641   -1.5530    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    3.9470    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    2.4470    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3301   -3.0530    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.2764   -1.7482    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -2.0530    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641   -3.5530    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.8600   -2.5530    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -3.0530    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    1.5670    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.1215    1.5547    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.5200    0.8644    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    2.3270    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690    2.7570    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.9875    0.0547    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.3860   -0.6356    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4860    3.9470    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    4.5670    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.2460    3.9470    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.6900    2.9840    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631    2.1370    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3100    1.9101    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.4690   -1.1589    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.0611   -1.7430    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641    2.0670    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.4690   -3.9470    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641   -4.1730    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.4800   -2.5530    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.0611   -3.3630    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  8  1  0  0  0  0<br>  1 10  1  0  0  0  0<br>  2  5  1  0  0  0  0<br>  2 34  1  0  0  0  0<br>  3  6  1  0  0  0  0<br>  3  7  1  0  0  0  0<br>  3 23  1  0  0  0  0<br>  4 13  1  0  0  0  0<br>  4 17  1  0  0  0  0<br>  4 35  1  0  0  0  0<br>  5  6  1  0  0  0  0<br>  5  8  1  0  0  0  0<br>  5 19  1  0  0  0  0<br>  6 20  1  0  0  0  0<br>  6 21  1  0  0  0  0<br>  7 11  1  0  0  0  0<br>  7 12  1  0  0  0  0<br>  7 22  1  0  0  0  0<br>  8 24  1  0  0  0  0<br>  8 25  1  0  0  0  0<br>  9 10  1  0  0  0  0<br>  9 13  2  0  0  0  0<br>  9 14  1  0  0  0  0<br> 10 15  2  0  0  0  0<br> 11 26  1  0  0  0  0<br> 11 27  1  0  0  0  0<br> 11 28  1  0  0  0  0<br> 12 29  1  0  0  0  0<br> 12 30  1  0  0  0  0<br> 12 31  1  0  0  0  0<br> 13 16  1  0  0  0  0<br> 14 17  2  0  0  0  0<br> 14 32  1  0  0  0  0<br> 15 18  1  0  0  0  0<br> 15 33  1  0  0  0  0<br> 16 18  2  0  0  0  0<br> 16 36  1  0  0  0  0<br> 17 37  1  0  0  0  0<br> 18 38  1  0  0  0  0<br>M  END
Compound Name

Pindolol

CID

4828

Molecular Formula

C14H20N2O2

Molecular Weight

248

No. Hydrogen Bond Acceptors

3

No. Hydrogen Bond Donors

3

Similar Applications

Reversed Phase

Beta-blockers using Luna Omega 1.6u PS C18 50x2.1mm

Luna Omega 1.6µm PS C18 100Å, LC Column 50 x 2.1 mm, EA

23727

Reversed Phase

ABN7 on Luna Omega 1.6u PS C18 50x2.1mm

Luna Omega 1.6µm PS C18 100Å, LC Column 50 x 2.1 mm, EA

23707

Reversed Phase

Beta-blockers using Luna Omega Polar C18 50x2.1mm

Luna Omega 1.6µm Polar C18 100Å, LC Column 50 x 2.1 mm, EA

23611

Chiral

Pindolol on Lux 5µm Amylose-1 by SFC

Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA

23290

Chiral

Pindolol on LUX Amylose-1 5u 250x4.6mm in PO

Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA

23182

Reversed Phase

ABN6 Mix on Kinetex 1.7u EVO C18 50x2.1mm

Kinetex 1.7 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, Ea

23068

Reversed Phase

Pharmaceutical Mix on Kinetex 1.7 F5 50x2.1mm

Kinetex 1.7 µm F5 100 Å, LC Column 50 x 2.1 mm, Ea

22813

Reversed Phase

Batch Reproducibility with ABN 7 mix- Kinetex 2.6u F5 50x4.6mm

Kinetex 2.6 µm F5 100 Å, LC Column 50 x 4.6 mm, Ea

22803

Reversed Phase

Batch reproducibility of Kinetex 5u EVO C18 150x4.6mm

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

22734

Reversed Phase

Pharma ABN Mixture using Kinetex 5u EVO C18 150x4.6mm

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

22718

Chiral

Pindolol on Lux 5µm Cellulose-4 by SFC

Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea

21311

Chiral

Pindolol on Lux 5µm Cellulose-4 by SFC

Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea

21310

Chiral

Pindolol on Lux 5µm Cellulose-4 by SFC

Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea

21309

Chiral

Pindolol on Lux 5µm Cellulose-3 by SFC

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

21308

Chiral

Pindolol on Lux 5µm Cellulose-3 by SFC

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

21307

Chiral

Pindolol on Lux 5µm Cellulose-3 by SFC

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

21306

Chiral

Pindolol on Lux 5µm Cellulose-3 by SFC

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

21305

Chiral

Pindolol on Lux 5µm Cellulose-2 by SFC

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

21304

Chiral

Pindolol on Lux 5µm Cellulose-1 by SFC

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

21303

Chiral

Pindolol on Lux 5µm Cellulose-1 by SFC

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

21302

Chiral

Mepindolol on Lux 5µm Cellulose-4 by SFC

Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea

21189

Chiral

Mepindolol on Lux 5µm Cellulose-4 by SFC

Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea

21188

Chiral

Mepindolol on Lux 5µm Cellulose-2 by SFC

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

21187

Chiral

Mepindolol on Lux 5µm Cellulose-2 by SFC

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

21186

Chiral

Mepindolol on Lux 5µm Cellulose-2 by SFC

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

21185

Chiral

Bopindolol on Lux 5µm Cellulose-4 by SFC

Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea

21065

Chiral

Bopindolol on Lux 5µm Cellulose-4 by SFC

Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea

21064

Chiral

Bopindolol on Lux 5µm Cellulose-3 by SFC

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

21063

Chiral

Bopindolol on Lux 5µm Cellulose-3 by SFC

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

21062

Chiral

Bopindolol on Lux 5µm Cellulose-3 by SFC

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

21061

Chiral

Bopindolol on Lux 5µm Cellulose-2 by SFC

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

21060

Chiral

Bopindolol on Lux 5µm Cellulose-1 by SFC

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

21059

Chiral

Bopindolol on Lux 5µm Cellulose-2 in NP

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

20492

Chiral

Pindolol on Lux 5µm Cellulose-3 in NP

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

20466

Chiral

Pindolol on Lux 5µm Cellulose-4 in NP

Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea

20350

Chiral

Pindolol on Lux 5µm Cellulose-1 in RP

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

20198

Chiral

Bopindolol on Lux 5µm Cellulose-4 in RP

Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea

20173

Chiral

Pindolol on Lux 5µm Cellulose-2 in NP

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

20125

Reversed Phase

Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 1.7u C18 100x2.1mm @ 0.60mL/min

Kinetex 1.7 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

20054

Reversed Phase

Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 2.6u C18 100x2.1mm @ 0.60mL/min

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

20053

Reversed Phase

Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 2.6 C18 100x2.1mm @ 1.0mL/min

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

20050

Reversed Phase

Pharma ABN Test 15 Mix on Un-Optimized Agilent 1100 system using Kinetex 2.6u C18 100x4.6mm

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea

20049

Reversed Phase

Pharma ABN Test 15 Mix on Optimized Agilent 1100 system using Kinetex 2.6u C18 100x4.6mm

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea

20048

Reversed Phase

Pharmaceutical Drug Mix on Kinetex 2.6 µm C18 50 x 2.1mm @ 0.8 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19944

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotien Data)

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19941

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 100 x 2.1mm @ 0.85 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

19940

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 75 x 2.1mm @ 1.1 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 75 x 2.1 mm, Ea

19939

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19914

Reversed Phase

Pharmaceutical Drug Mix on Kinetex 2.6 µm C18 50 x 2.1mm @ 0.8 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19911

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19862

Reversed Phase

Pharmaceutical Mixture on Kinetex 2.6µm C8 50x2.1mm ID

Kinetex 2.6 µm C8 100 Å, LC Column 50 x 2.1 mm, Ea

19476

Reversed Phase

Pharmaceutical Mixture on Kinetex XB-C18

Kinetex 2.6 µm XB-C18 100 Å, LC Column 50 x 2.1 mm, Ea

19475

Reversed Phase

Pharmaceutical Mixture on Kinetex C18

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19474

Chiral

Bopindolol on Lux 5µm Cellulose-1 in NP

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

19193

Chiral

Bopindolol on Lux 5 µm Cellulose-1 by Chiral SFC

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

18861

Chiral

Bopindolol on Lux 5 µm Cellulose-2 by Chiral SFC

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

18860

Chiral

Pindolol on Lux 5µ Cellulose-2 in RP 20% CH3CN

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

17868

Chiral

Pindolol on Lux 5µ Cellulose-2 in RP 60%MeOH

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

17865

Chiral

Pindolol on Lux 5µ Cellulose-1 in RP 80% MeOH-2

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

17864

Chiral

Pindolol on Lux 5µ Cellulose-1 in RP 80% MeOH-1

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

17863

Chiral

Pindolol on Lux 5µ Cellulose-1 in RP 60% CH3CN

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

17862

Chiral

Pindolol on Lux 5µ Cellulose-1 in RP 40% CH3CN

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

17861

Chiral

Bopindolol on Lux Cellulose-2

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

17484

Chiral

Bopindolol on Lux Cellulose-1

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

17483

Chiral

Pindolol on Lux Cellulose-1

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

17384

Chiral

Bopindolol on Lux Cellulose-1

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

16715