Basic Compounds at High pH Using Gemini 10u C18 Axia Packed 50x21.2mm

Basic Compounds at High pH Using Gemini 10u C18 Axia Packed 50x21.2mm
LC Conditions
Column

Gemini 10 µm C18 110 Å, LC Column 50 x 21.2 mm, AXIA Packed, Ea

Brand

Gemini

Part No

00B-4436-P0-AX

Phase Name

C18

Elution Type

Gradient

Mobile Phase

A: 95:5 50mM Ammonium Bicarbonate:Acetonitrile

B: 5:95 50mM Ammonium Bicarbonate:Acetonitrile

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

100

0

2

7

0

100

Flow Rate

30.00 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

Compare to App ID 15928: Selectivity to low pH on Luna 5µm C18(2) Axia Packed column.

Order Items Used in This Application

Gemini 10 µm C18 110 Å, LC Column 50 x 21.2 mm, AXIA Packed, Ea
00B-4436-P0-AX

Gemini 10 µm C18 110 Å, LC Column 50 x 21.2 mm, AXIA Packed, Ea

View Product

  • 1. Triprolidine
  • 2. Methacycline
  • 3. Amitriptyline
-OEChem-05081000432D<br><br> 43 45  0     0  0  0  0  0  0999 V2000<br>    3.5827    1.5000    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.9128    1.0000    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4782    2.4945    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.6691    1.0933    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.5000    2.7024    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    1.8364    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.4487    1.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.3147    1.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.1808    1.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.1808    0.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.0468    1.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.0468   -0.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.3147   -0.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.0468    2.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.1808   -2.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.0468   -1.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.3147   -1.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.9128    3.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.1808   -3.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.7788    1.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.7788    2.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.0982    2.4945    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.5430    3.1111    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.1675    0.7288    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.9791    0.5563    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.6916    3.2921    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.9336    2.9546    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4984    2.2008    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.5851    1.3757    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.0502    0.5251    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.8472    0.5251    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.3147    2.1200    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.5837   -0.1900    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.7778   -0.1900    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.5098    2.8100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.5837   -1.8100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.7778   -1.8100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.9128    3.6200    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.5608   -3.0000    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.1808   -3.6200    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.8008   -3.0000    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    9.3158    1.1900    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    9.3158    2.8100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  3  1  0  0  0  0<br>  1  4  1  0  0  0  0<br>  1  7  1  0  0  0  0<br>  2 11  1  0  0  0  0<br>  2 20  2  0  0  0  0<br>  3  5  1  0  0  0  0<br>  3 22  1  0  0  0  0<br>  3 23  1  0  0  0  0<br>  4  6  1  0  0  0  0<br>  4 24  1  0  0  0  0<br>  4 25  1  0  0  0  0<br>  5  6  1  0  0  0  0<br>  5 26  1  0  0  0  0<br>  5 27  1  0  0  0  0<br>  6 28  1  0  0  0  0<br>  6 29  1  0  0  0  0<br>  7  8  1  0  0  0  0<br>  7 30  1  0  0  0  0<br>  7 31  1  0  0  0  0<br>  8  9  2  0  0  0  0<br>  8 32  1  0  0  0  0<br>  9 10  1  0  0  0  0<br>  9 11  1  0  0  0  0<br> 10 12  2  0  0  0  0<br> 10 13  1  0  0  0  0<br> 11 14  2  0  0  0  0<br> 12 16  1  0  0  0  0<br> 12 33  1  0  0  0  0<br> 13 17  2  0  0  0  0<br> 13 34  1  0  0  0  0<br> 14 18  1  0  0  0  0<br> 14 35  1  0  0  0  0<br> 15 16  2  0  0  0  0<br> 15 17  1  0  0  0  0<br> 15 19  1  0  0  0  0<br> 16 36  1  0  0  0  0<br> 17 37  1  0  0  0  0<br> 18 21  2  0  0  0  0<br> 18 38  1  0  0  0  0<br> 19 39  1  0  0  0  0<br> 19 40  1  0  0  0  0<br> 19 41  1  0  0  0  0<br> 20 21  1  0  0  0  0<br> 20 42  1  0  0  0  0<br> 21 43  1  0  0  0  0<br>M  END
Compound Name

Triprolidine

CID

5282443

Molecular Formula

C19H22N2

Molecular Weight

278

No. Hydrogen Bond Acceptors

2

Similar Applications

Reversed Phase

Kinetex 2.6u C18 100A and LC Column 150 x 0.3 mm- Pharma Screen

Kinetex 2.6 µm C18 100 Å, LC Column 150 x 0.3 mm, Capillary, Ea

26400

Reversed Phase

Kinetex 2.6u C18 100A, LC Column 50 x 0.3 mm- Pharma Screen

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 0.3 mm, Capillary, Ea

26399

Reversed Phase

Kinetex 2.6u XB-C18 100A, LC Column 50 x 0.3 mm- Pharma Screen

Kinetex 2.6 µm XB-C18 100 Å, LC Column 50 x 0.3 mm, microflow, Ea

26324

Reversed Phase

Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 1.7u C18 100x2.1mm @ 0.60mL/min

Kinetex 1.7 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

20054

Reversed Phase

Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 2.6u C18 100x2.1mm @ 0.60mL/min

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

20053

Reversed Phase

Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 2.6 C18 100x2.1mm @ 1.0mL/min

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

20050

Reversed Phase

Pharma ABN Test 15 Mix on Un-Optimized Agilent 1100 system using Kinetex 2.6u C18 100x4.6mm

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea

20049

Reversed Phase

Pharma ABN Test 15 Mix on Optimized Agilent 1100 system using Kinetex 2.6u C18 100x4.6mm

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea

20048

Reversed Phase

Pharma ABN Test 15 Mix on Kinetex 2.6u C18 50x2.10mm @ 1.45mL/min 5min gradient

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

20041

Reversed Phase

Pharma ABN Test 15 Mix on Kinetex 1.7u C18 50x2.10mm @ 1.0mL/min 5min gradient

Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

20040

Reversed Phase

Pharma ABN Test 15 Mix on Kinetex 2.6u C18 50x2.10mm @ 0.8mL/min 5 ming gradient

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

20039

Reversed Phase

Pharmaceutical Drug Mix on Kinetex 2.6 µm C18 50 x 2.1mm @ 0.8 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19945

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19942

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 100 x 2.1mm @ 0.85 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

19940

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 75 x 2.1mm @ 1.1 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 75 x 2.1 mm, Ea

19939

Reversed Phase

Pharmaceutical Drug Mix on Kinetex 2.6 µm C18 50 x 2.1mm @ 0.8 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19911

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19862

Reversed Phase

Pharma ABN Test 11 Mix on Kinetex 2.6u C18 150x2.10mm using Acquity UPLC system

Kinetex 2.6 µm C18 100 Å, LC Column 150 x 2.1 mm, Ea

19789

Reversed Phase

Pharma ABN Test 11 Mix on Kinetex 1.7u C18 150x2.10mm using Acquity UPLC system

Kinetex 1.7 µm XB-C18 100 Å, LC Column 150 x 2.1 mm, Ea

19788

Reversed Phase

Pharma ABN Test 12 Mix on Kinetex 1.7u C18 50x2.10mm using Acquity UPLC system

Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19785

Reversed Phase

Pharma ABN Test 12 Mix on Kinetex 2.6u C18 50x2.10mm using Acquity UPLC system

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19784

Reversed Phase

Pharmaceutical Mixture on Kinetex 2.6µm C8 50x2.1mm ID

Kinetex 2.6 µm C8 100 Å, LC Column 50 x 2.1 mm, Ea

19476

Reversed Phase

Pharmaceutical Mixture on Kinetex XB-C18

Kinetex 2.6 µm XB-C18 100 Å, LC Column 50 x 2.1 mm, Ea

19475

Reversed Phase

Pharmaceutical Mixture on Kinetex C18

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19474