Organochlorine Pesticides in Water by GC/ECD
GC Conditions
Column
Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
Part No
7HM-G017-11
Phase Name
ZB-MultiResidue-2
Injection
On-Column @ 103°C
Carrier Gas
Constant Flow Helium, 1.8 mL/min
Detection
Electron Capture (ECD) @ (340°C)
Detection Info
Sample Notes
Analytes of varying concentration at or near 50ppb.
Order Items Used in This Application
- 1. Hexachlorocyclopentadiene
- 2. Etridiazole
- 3. Chloroneb
- 4. Trifluralin
- 5. Propachlor
- 6. alpha-BHC
- 7. Hexachlorobenzene
- 8. Atrazine
- 9. gamma-BHC
- 10. Simazine
- 11. b-BHC
- 12. Alachlor
- 13. delta-BHC
- 14. Chlorothalonil
- 15. Heptachlor
- 16. Chlorpyrifos
- 17. Dacthal
- 18. Aldrin
- 19. Heptachlor epoxide
- 20. trans-Chlordane
- 21. cis-Chlordane
- 22. Endosulfan I
- 23. 4,4'-DDE
- 24. Dieldrin
- 25. Chlorobenzilate
- 26. Endrin
- 27. 4,4'-DDD
- 28. Endosulfan II
- 29. Endrin aldehyde
- 30. 4,4'-DDT
- 31. Endosulfan sulfate
- 32. Methoxychlor
- 33. Endrin ketone
- 34. Permethrin
- 35. Permethrin
Similar Applications