TMS Sugars on ZB-MR1

TMS Sugars on ZB-MR1
GC Conditions
Column

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

Part No

7HG-G016-11

Phase Name

ZB-MultiResidue-1

Injection

Split 100:1 @ 225°C

Carrier Gas

Constant Flow Helium, 2.0 mL/min

Detection

Flame Ionization (FID) @ (250°C)

Detection Info
Sample Notes

Sugar mix concentration 176 ppm. Sample was blown dry and then reconstituted in 100uL of 1:1 pyridine/BSTFA+1%TCMS, then heated at 70 °C for 20 minutes, cooled to room temperature, then injected.

Order Items Used in This Application

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
7HG-G016-11

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

View Product

  • 1. D-(-)-Arabinose
  • 2. d-Ribose
  • 3. d-Xylose
  • 4. D-Mannose
  • 5. D-(+)-Galactose
  • 6. alpha-d-Glucose
  • 7. beta-D-(+)-Glucose
Similar Applications