Steroid Mix (4) on Luna PFP(2)
LC Conditions
Column
Luna 5 µm PFP(2) 100 Å, LC Column 150 x 4.6 mm, Ea
Brand
Luna
Part No
00F-4448-E0
Phase Name
PFP(2)
Elution Type
Gradient
Mobile Phase
A: Water
B: Acetonitrile
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
60
40
2
8
30
70
3
10
30
70
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, PFP 4 x 3.0 mm, 10/Pk Part No.: AJ0-8327 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Prednisone
- 2. Prednisolone
- 3. Hydroxyprogesterone
- 4. Progesterone
-OEChem-06211003152D<br><br> 52 55 0 1 0 0 0 0 0999 V2000<br> 8.0319 1.8625 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7950 1.1062 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.0465 2.4920 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.8722 1.6754 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -2.4462 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3931 0.6062 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 7.3931 -0.3938 0.0000 C 0 0 2 0 0 0 0 0 0 0 0 0<br> 6.5271 -0.8938 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 5.6610 -0.3938 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 8.3393 0.9109 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 8.3393 -0.6986 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5271 1.1062 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.9229 0.1062 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7510 -0.9007 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 6.5431 -1.9353 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6610 0.6062 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3931 1.6062 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6451 -2.4631 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7430 -1.9423 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.1493 1.4973 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7587 0.0993 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.8242 -0.3366 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.8076 -2.4920 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.0622 1.0890 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8763 -0.8645 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8680 -1.9495 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.4830 -1.2390 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.2664 -1.3131 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3972 0.0312 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0883 -1.2655 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.8767 -1.0078 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.9256 1.5811 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.1285 1.5811 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.3838 -0.3086 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.3838 0.5209 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7612 -2.5157 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1523 -1.8198 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0131 1.6062 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3931 2.2262 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7731 1.6062 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2478 -2.9390 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0460 -2.9360 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.3787 0.0945 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7635 0.7193 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.1388 0.1041 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.8361 0.2833 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.4476 2.3225 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.8100 -3.1120 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.7146 0.5756 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.5074 0.6575 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3430 -0.5483 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 11.4382 1.4222 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 10 1 1 6 0 0 0<br> 1 47 1 0 0 0 0<br> 2 16 2 0 0 0 0<br> 3 20 2 0 0 0 0<br> 4 24 1 0 0 0 0<br> 4 52 1 0 0 0 0<br> 5 26 2 0 0 0 0<br> 6 7 1 0 0 0 0<br> 6 10 1 0 0 0 0<br> 6 12 1 0 0 0 0<br> 6 17 1 1 0 0 0<br> 7 8 1 0 0 0 0<br> 7 11 1 0 0 0 0<br> 7 27 1 6 0 0 0<br> 8 9 1 0 0 0 0<br> 8 15 1 0 0 0 0<br> 8 28 1 1 0 0 0<br> 9 14 1 0 0 0 0<br> 9 16 1 0 0 0 0<br> 9 29 1 6 0 0 0<br> 10 13 1 0 0 0 0<br> 10 20 1 0 0 0 0<br> 11 13 1 0 0 0 0<br> 11 30 1 0 0 0 0<br> 11 31 1 0 0 0 0<br> 12 16 1 0 0 0 0<br> 12 32 1 0 0 0 0<br> 12 33 1 0 0 0 0<br> 13 34 1 0 0 0 0<br> 13 35 1 0 0 0 0<br> 14 19 1 0 0 0 0<br> 14 21 1 1 0 0 0<br> 14 22 1 0 0 0 0<br> 15 18 1 0 0 0 0<br> 15 36 1 0 0 0 0<br> 15 37 1 0 0 0 0<br> 17 38 1 0 0 0 0<br> 17 39 1 0 0 0 0<br> 17 40 1 0 0 0 0<br> 18 19 1 0 0 0 0<br> 18 41 1 0 0 0 0<br> 18 42 1 0 0 0 0<br> 19 23 2 0 0 0 0<br> 20 24 1 0 0 0 0<br> 21 43 1 0 0 0 0<br> 21 44 1 0 0 0 0<br> 21 45 1 0 0 0 0<br> 22 25 2 0 0 0 0<br> 22 46 1 0 0 0 0<br> 23 26 1 0 0 0 0<br> 23 48 1 0 0 0 0<br> 24 49 1 0 0 0 0<br> 24 50 1 0 0 0 0<br> 25 26 1 0 0 0 0<br> 25 51 1 0 0 0 0<br>M END
Compound Name
Prednisone
CID
5865
Molecular Formula
C21H26O5
Molecular Weight
358
No. Hydrogen Bond Acceptors
5
No. Hydrogen Bond Donors
2
Similar Applications
Reversed Phase
Cortisol/Cortisone Chromatogram_QCH (1600 ng/mL)
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22170
Reversed Phase
Prednisolone/Prednisone Chromatogram_QCH (1600 ng/mL)
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22169
Reversed Phase
Prednisolone Chromatogram_LLOQ (10 ng/mL)
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22168
Reversed Phase
Prednisone Chromatogram_LLOQ (10 ng/mL)
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22167
Reversed Phase
Cortisone Chromatogram_LLOQ (10 ng/mL)
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22166
Reversed Phase
Cortisol Chromatogram_LLOQ (10 ng/mL)
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22165
Reversed Phase
Cortisone/cortisol representative of curve
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22164
Reversed Phase
Steroid panel using Kinetex 2.6u Biphenyl 50x2.1mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea
21999
Reversed Phase
Steroids on Kinetex Biphenyl 2.6µm 50x4.6mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 4.6 mm, Ea
21966
Steroids on Onyx C18 100 x 4.6 mm - CH3CN Modifier
19996
Steroids on Onyx C18 100 x 4.6 mm - MeOH Modifier
19994
Reversed Phase
Steroids Mix on Kinetex 2.6µ C18
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 4.6 mm, Ea
19992
Reversed Phase
Steroids Mix on Kinetex 2.6µ Phenyl-Hexyl
Kinetex 2.6 µm Phenyl-Hexyl 100 Å, LC Column 50 x 4.6 mm, Ea
19991
Reversed Phase
Steroids on Kinetex 2.6µm C18 150 x 4.6mm ID
Kinetex 2.6 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
18682
Reversed Phase
Steroids on Luna 3µm PFP(2) 50 x 2mm ID (in acetonitrile)
Luna 3 µm PFP(2) 100 Å, LC Column 50 x 2 mm, Ea
18508
Reversed Phase
Steroids on Kinetex 2.6µm C18 50 x 2.1mm ID (in acetonitrile)
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
18507
Reversed Phase
Steroid Mix (11) on Luna 5um PFP(2)
Luna 5 µm PFP(2) 100 Å, LC Column 150 x 4.6 mm, Ea
16291
Reversed Phase
Steroid Mix (11) on Luna 3um PFP(2)
Luna 3 µm PFP(2) 100 Å, LC Column 150 x 4.6 mm, Ea
16290
Reversed Phase
Steroid Mix (4) on Luna C18(2)
Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea
16289
Reversed Phase
Steroid Mix (4) on Luna PFP(2)
Luna 5 µm PFP(2) 100 Å, LC Column 150 x 4.6 mm, Ea
16288
Normal Phase
Corticosteroids
Luna 3 µm CN 100 Å, LC Column 100 x 4.6 mm, Ea
12946
Normal Phase
Corticosteroids
Luna 5 µm CN 100 Å, LC Column 150 x 4.6 mm, Ea
12924