Water-Soluble Vitamin Mixture on Luna 5µm HILIC, pH 3.2
LC Conditions
Column
Luna 5 µm HILIC 200 Å, LC Column 150 x 4.6 mm, Ea
Brand
Luna
Part No
00F-4450-E0
Phase Name
HILIC
Elution Type
Gradient
Mobile Phase
A: Acetonitrile
B: Water
C: 100mM Ammonium Formate pH 3.2
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
90
5
2
2.5
90
5
3
10
50
45
4
12.5
50
45
Flow Rate
2.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Diode Array (PDA) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, HILIC 4 x 3.0 mm, 10/Pk Part No.: AJ0-8329 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. PABA
- 2. Nicotinamide
- 3. Riboflavin
- 4. Nicotinic acid
- 5. Pyridoxine
- 6. Thiamine
- 7. Ascorbic acid
- 8. Vitamin B12
- 9. Folic acid
Similar Applications