Polynuclear Aromatic Hydrocarbons (PAHs) on ZB-MR1
GC Conditions
Column
Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
Part No
7HG-G016-11
Phase Name
ZB-MultiResidue-1
Injection
Splitless @ 260°C
Carrier Gas
Constant Flow Helium, 1.2 mL/min
Detection
Mass Selective (MSD) @ (180°C)
Detection Info
Sample Notes
Column with 5 meter guard. Analytes are 1.0 ppm. Application courtesy of Annegret Tischendorf, Südsachsen Wasser GmbH
Order Items Used in This Application
- 1. Naphthalene
- 2. Acenaphthalene
- 3. Acenaphthene
- 4. Fluorene
- 5. Phenanthrene
- 6. Anthracene
- 7. Fluoranthene
- 8. Pyrene
- 9. Benz[a]anthracene
- 10. Chrysene
- 11. Benzo[b]fluroanthene
- 12. Benzo[k]fluroanthene
- 13. Benzo[a]pyrene
- 14. Dibenz[a,h]anthracene
- 15. Indeno[1,2,3-cd]pyrene
- 16. Benzo[g,h,i]perylene
Similar Applications