Cough & Cold Compounds on Luna SCX
LC Conditions
Column
Luna 5 µm SCX 100 Å, LC Column 150 x 4.6 mm, Ea
Brand
Luna
Part No
00F-4398-E0
Phase Name
SCX
Elution Type
Isocratic
Mobile Phase
A: 50mM Sodium Phosphate
B: Acetonitrile
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
40
60
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Order Items Used in This Application
- 1. Benzoic Acid
- 2. Diphenhydramine
- 3. Dextromethorophan
- 4. Phenylephrine
-OEChem-06211003142D<br><br> 15 15 0 0 0 0 0 0 0999 V2000<br> 3.7320 1.4400 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 1.4400 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -0.0600 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.5600 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.5600 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -1.5600 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.5600 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -2.0600 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 0.9400 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -0.2500 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -0.2500 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -1.8700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -1.8700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -2.6800 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 2.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 9 1 0 0 0 0<br> 1 15 1 0 0 0 0<br> 2 9 2 0 0 0 0<br> 3 4 2 0 0 0 0<br> 3 5 1 0 0 0 0<br> 3 9 1 0 0 0 0<br> 4 6 1 0 0 0 0<br> 4 10 1 0 0 0 0<br> 5 7 2 0 0 0 0<br> 5 11 1 0 0 0 0<br> 6 8 2 0 0 0 0<br> 6 12 1 0 0 0 0<br> 7 8 1 0 0 0 0<br> 7 13 1 0 0 0 0<br> 8 14 1 0 0 0 0<br>M END
Compound Name
Benzoic Acid
CID
243
Molecular Formula
C7H6O2
Molecular Weight
122
No. Hydrogen Bond Acceptors
2
No. Hydrogen Bond Donors
1
Similar Applications
Reversed Phase
ABN3 mix on Luna Omega 5 µm C18 250x4.6mm (Batch 3) using Agilent 1260 Binary UHPLC system
Luna Omega 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea
26496
Reversed Phase
ABN3 mix on Luna Omega 5 µm C18 250x4.6mm (Batch 2) using Agilent 1260 Binary UHPLC system
Luna Omega 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea
26495
Reversed Phase
ABN3 mix on Luna Omega 5 µm C18 250x4.6mm (Batch 1) using Agilent 1260 Binary UHPLC system
Luna Omega 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea
26494
Reversed Phase
ABN3 mix on Luna Omega 3 µm C18 150x4.6mm (Batch 3) using Agilent 1260 Binary UHPLC system
Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
26487
Reversed Phase
ABN3 mix on Luna Omega 3 µm C18 150x4.6mm (Batch 2) using Agilent 1260 Binary UHPLC system
Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
26486
Reversed Phase
ABN3 mix on Luna Omega 3 µm C18 150x4.6mm (Batch 1) using Agilent 1260 Binary UHPLC system
Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
26485
Reversed Phase
ABN3 mix on Luna Omega 1.6 µm C18 50x2.1mm (Batch 3) using Agilent 1260 Binary UHPLC system
Luna Omega 1.6µm C18 100Å, LC Column 50 x 2.1 mm, EA
26478
Reversed Phase
ABN3 mix on Luna Omega 1.6 µm C18 50x2.1mm (Batch 2) using Agilent 1260 Binary UHPLC system
Luna Omega 1.6µm C18 100Å, LC Column 50 x 2.1 mm, EA
26477
Reversed Phase
ABN3 mix on Luna Omega 1.6 µm C18 50x2.1mm (Batch 1) using Agilent 1260 Binary UHPLC system
Luna Omega 1.6µm C18 100Å, LC Column 50 x 2.1 mm, EA
26476
Reversed Phase
USP Butamben Impurity Standard Solution 0.2 µg/mL on Kinetex 5 µm XB-C18 100 x 2.1 mm on Agilent 1260 UHPLC
Kinetex 5 µm XB-C18 100 Å, LC Column 100 x 2.1 mm, Ea
26338
Application Specific
EPA 8151 by GC/ECD on ZB-CLPesticides-2 (Hydrogen Gas)
Zebron ZB-CLPesticides-2, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
23633
Application Specific
EPA 8151 by GC/ECD on ZB-CLPesticides-1 (Hydrogen Gas)
Zebron ZB-CLPesticides-1, GC Cap. Column 30 m x 0.32 mm x 0.32 µm, Ea
23632
Reversed Phase
Analgesics Mix 9 on Luna Omega 1.6u C18 50x2.1mm
Luna Omega 1.6µm C18 100Å, LC Column 50 x 2.1 mm, EA
23485
Reversed Phase
ABN6 Mix on Kinetex 1.7u EVO C18 50x2.1mm
Kinetex 1.7 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, Ea
23068
Reversed Phase
Mix of Analytes on Kinetex 1.7u EVO C18 50x2.1mm
Kinetex 1.7 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, Ea
22999
Reversed Phase
Mix of Analytes on Kinetex 5u EVO C18 150x4.6mm
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
22998
Reversed Phase
Food Additives on a Kinetex 2.6u F5 150 x 2.1mm
Kinetex 2.6 µm F5 100 Å, LC Column 150 x 2.1 mm, Ea
22817
Reversed Phase
Batch Reproducibility with ABN 7 mix- Kinetex 2.6u F5 50x4.6mm
Kinetex 2.6 µm F5 100 Å, LC Column 50 x 4.6 mm, Ea
22803
Reversed Phase
Batch reproducibility of Kinetex 5u EVO C18 150x4.6mm
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
22734
Reversed Phase
Pharma ABN Mixture using Kinetex 5u EVO C18 150x4.6mm
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
22718
Application Specific
EPA 8151 by GC/ECD on ZB-CLPesticides-2 (Helium Gas)
Zebron ZB-CLPesticides-2, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
22620
Application Specific
EPA 8151 by GC/ECD on ZB-CLPesticides-1 (Helium Gas)
Zebron ZB-CLPesticides-1, GC Cap. Column 30 m x 0.32 mm x 0.32 µm, Ea
22619
Reversed Phase
Water soluble vitamins on Kinetex 2.6µm C18, 100x4.6mm
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea
20596
Application Specific
EPA Method 8270D on Zebron ZB-SemiVolatiles
Zebron ZB-SemiVolatiles, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
20582
Application Specific
Phenols on Zebron ZB-SemiVolatiles
Zebron ZB-SemiVolatiles, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
20579
Application Specific
Fast EPA Method 8270D on Zebron ZB-SemiVolatiles
Zebron ZB-SemiVolatiles, GC Cap. Column 20 m x 0.18 mm x 0.36 µm, Ea
20572
Application Specific
Fast Phenols on Zebron ZB-SemiVolatiles
Zebron ZB-SemiVolatiles, GC Cap. Column 20 m x 0.18 mm x 0.36 µm, Ea
20570
Reversed Phase
Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 1.7u C18 100x2.1mm @ 0.60mL/min
Kinetex 1.7 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
20054
Reversed Phase
Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 2.6u C18 100x2.1mm @ 0.60mL/min
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
20053
Reversed Phase
Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 2.6 C18 100x2.1mm @ 1.0mL/min
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
20050
Reversed Phase
Pharma ABN Test 15 Mix on Un-Optimized Agilent 1100 system using Kinetex 2.6u C18 100x4.6mm
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea
20049
Reversed Phase
Pharma ABN Test 15 Mix on Optimized Agilent 1100 system using Kinetex 2.6u C18 100x4.6mm
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea
20048
Reversed Phase
Soft Drink Additives (Coke Zero) on Kinetex 2.6u C18 100x4.60mm on Shimadzu Nexera
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea
19971
Reversed Phase
USP Acetaminophen Acetylsalicylic Acid Caffeine on Kinetex 1.7u C18 100x2.10mm on Shimadzu Nexera
Kinetex 1.7 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
19959
Reversed Phase
USP Acetaminophen, Acetylsalicylic Acid, Caffeine on Kinetex 2.6u C18 100x2.10mm on Shimadzu Nexera
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
19958
Reversed Phase
USP Acetaminophen, Acetylsalicylic Acid, Caffeine on Kinetex 2.6u C18 75x4.60mm on Shimadzu Nexera
Kinetex 2.6 µm C18 100 Å, LC Column 75 x 4.6 mm, Ea
19957
Reversed Phase
USP Acetaminophen, Acetylsalicylic Acid, Caffeine on Kinetex 2.6u C18 100x4.60mm on Shimadzu Nexera
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea
19956
Reversed Phase
Soft Drink Additives (Coke Zero) on Kinetex 1.7u C18 100x2.10mm on Shimadzu Nexera
Kinetex 1.7 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
19954
Reversed Phase
Preservatives Analysis using Luna 3µm C18(2) 100x4.6mm
Luna 3 µm C18(2) 100 Å, LC Column 100 x 4.6 mm, Ea
19500
Reversed Phase
Pharmaceutical Mixture on Kinetex 2.6µm C8 50x2.1mm ID
Kinetex 2.6 µm C8 100 Å, LC Column 50 x 2.1 mm, Ea
19476
Reversed Phase
Pharmaceutical Mixture on Kinetex XB-C18
Kinetex 2.6 µm XB-C18 100 Å, LC Column 50 x 2.1 mm, Ea
19475
Reversed Phase
Pharmaceutical Mixture on Kinetex C18
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19474
High Temperature
EPA Method 8151 - Chlorinated Herbicides on a ZB-XLB-HT 30x0.32x0.25 (Dual column)
Zebron ZB-XLB-HT, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
19283
High Temperature
EPA Method 8151 - Chlorinated Herbicides on a ZB-35-HT 30x0.32x0.25 (Dual column)
Zebron ZB-35HT, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
19282
High Temperature
EPA Method 8151 - Chlorinated Herbicides on a ZB-XLB-HT(Dual column)
Zebron ZB-XLB-HT, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
18789
High Temperature
EPA Method 8151 - Chlorinated Herbicides on a ZB-35-HT(Dual column)
Zebron ZB-35HT, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
18788
Application Specific
EPA Method 8151A on MR1 (Carrier Gas: Helium)
Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea
16764
Standard
EPA Method 8151A on ZB-35 (Carrier Gas: Helium)
Zebron ZB-35, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
16758
Standard
EPA Method 8270C on ZB-XLB
Zebron ZB-XLB, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16584
Application Specific
EPA 8151A on MR2 (Carrier Gas: Helium)
Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
16576
Application Specific
EPA 8151A on MR2 (Carrier Gas: Hydrogen)
Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
16566
Standard
EPA 8151A on ZB-35 (Carrier Gas: Hydrogen)
Zebron ZB-35, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
16562
Standard
Ylang Ylang Oil on ZB-XLB
Zebron ZB-XLB, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16479
Standard
EPA 8151A Chlorinated Herbicides on ZB-XLB
Zebron ZB-XLB, GC Cap. Column 30 m x 0.25 mm x 0.50 µm, Ea
16464
8270 Phenols Mix on ZB-5MSi
16454
EPA Method 8270C ZB-5MSi
16413
8270 Phenol Mix ZB-5msi
16411
Application Specific
EPA Method 8270C on ZB-MR1
Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16275
Application Specific
EPA Method 8151: Chlorinated Herbicides on ZB-MR2
Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
16186
Application Specific
EPA Method 8151: Chlorinated Herbicides on ZB-MR1
Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea
16185
Application Specific
Screening of Pesticides by GC-MS on ZB-MultiResidue-1
Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16184
Application Specific
Screening of Pesticide by GC/MS on ZB-MR2
Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.25 mm x 0.20 µm, Ea
16183
Reversed Phase
Food Additives using Gemini 5u C6-Phenyl
Gemini 5 µm C6-Phenyl 110 Å, LC Column 150 x 4.6 mm, Ea
15902
Reversed Phase
Food Additives using Gemini 5u C6-Phenyl
Gemini 5 µm C6-Phenyl 110 Å, LC Column 150 x 4.6 mm, Ea
15901
Reversed Phase
Soft Drink Application using Gemini 5u C6-Phenyl
Gemini 5 µm C6-Phenyl 110 Å, LC Column 150 x 4.6 mm, Ea
15892
Reversed Phase
Soft Drink Application using Gemini 5u C6-Phenyl
Gemini 5 µm C6-Phenyl 110 Å, LC Column 150 x 4.6 mm, Ea
15891
Reversed Phase
Saccharin analysis using Synergi Polar-RP
Synergi 4 µm Polar-RP 80 Å, LC Column 150 x 4.6 mm, Ea
15809
Reversed Phase
Saccharin analysis using Luna C18(2)
Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea
15808
Reversed Phase
Saccharin analysis using Luna Phenyl-Hexyl
Luna 5 µm Phenyl-Hexyl 100 Å, LC Column 150 x 4.6 mm, Ea
15807
Standard
EPA Method 515.2: Chlorinated Acids on ZB-1701
Zebron ZB-1701, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
15791
Standard
EPA Method 515.2: Chlorinated Acids on ZB-5
Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
15790
Standard
EPA Method 8270C: Semivolatile Organic Analysis on ZB-5MS
Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.32 µm, Ea
15696
Standard
EPA Method 8270C: Semivolatile Organic Analysis on ZB-5MS
Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea
15695
Reversed Phase
Energy Drink Components on Onyx C18 at 2.0mL/min.
Onyx Monolithic C18, LC Column 50 x 4.6 mm, Ea
15521
Reversed Phase
Energy Drink Components on Onyx C18 at 1.0mL/min.
Onyx Monolithic C18, LC Column 50 x 4.6 mm, Ea
15520
Reversed Phase
Energy Drink Components on Onyx C18 using gradual flow gradient
Onyx Monolithic C18, LC Column 50 x 4.6 mm, Ea
15519
Reversed Phase
Energy Drink Components with flow gradient on Onyx C18
Onyx Monolithic C18, LC Column 50 x 4.6 mm, Ea
15515
Reversed Phase
Energy Drink Components on Onyx C18
Onyx Monolithic C18, LC Column 50 x 4.6 mm, Ea
15506
Standard
Phenols on ZB-5MS
Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
14955
Standard
EPA Method 8270C on ZB-5MS 30x0.25x0.25
Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
14953
Standard
EPA Method 8270C on Guardian on ZB-5
Zebron ZB-5 w/GUARDIAN, 5 m, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
14945
Standard
8270 Semi-Volatile Organic Analysis on ZB-5
Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
14567
Reversed Phase
EPA Method 555B, Chlorinated Acids
Synergi 4 µm Hydro-RP 80 Å, LC Column 150 x 4.6 mm, Ea
14479
Standard
Semivolatiles (BNA) by GC/MS (EPA Method 8270C)
Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.50 µm, Ea
14442
Reversed Phase
Multivitamin tablet on Synergi Hydro-RP
Synergi 4 µm Hydro-RP 80 Å, LC Column 150 x 4.6 mm, Ea
14235
Reversed Phase
Artificial sweeteners
Prodigy 5 µm ODS-3 100 Å, LC Column 150 x 4.6 mm, Ea
13339
Reversed Phase
Food Additives
Prodigy 5 µm Phenyl-3 (PH-3) 100 Å, LC Column 150 x 4.6 mm, Ea
10257
Reversed Phase
Organic Compounds
Luna 5 µm Phenyl-Hexyl 100 Å, LC Column 150 x 4.6 mm, Ea
1220
Reversed Phase
Food Additives on Luna 5u Phenyl-Hexyl
Luna 5 µm Phenyl-Hexyl 100 Å, LC Column 150 x 4.6 mm, Ea
1199