Extraction of Amphetamines on Strata-X-C

Extraction of Amphetamines on Strata-X-C
LC Conditions
Column

Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea

Brand

Luna

Part No

00F-4252-E0

Phase Name

C18(2)

Elution Type

Gradient

Mobile Phase

A: 20 mM KH2PO4

B: ACN

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

95

5

2

7

75

25

Flow Rate

1.50 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Fixed Wave. (UV) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, C18 4 x 3.0mm, 10/Pk Part No.: AJ0-4287 - Holder Part No.: KJ0-4282

Sample Preparation Details
Condition 1

1 mL Methanol

Condition 2

1 mL Water

Load

Load 0.50 mL Sample diluted in Buffer

Wash 1

1 mL Methanol:Acid

Wash 2

1 mL Methanol

Wash 3

1 mL

Elution 1

1 mL Ammoniacal methanol

Evaporation

Evaporate to dryness

Reconstitute

1 mL Mobile Phase

Order Items Used in This Application

Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea
00F-4252-E0

Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea

View Product

  • 1. Ephedrine
  • 2. Amphetamine
  • 3. Methamphetamine
-OEChem-06211003152D<br><br> 27 27  0     1  0  0  0  0  0999 V2000<br>    2.0000    1.0000    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    2.0000    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    1.0000    0.0000 C   0  0  3  0  0  0  0  0  0  0  0  0<br>    2.8660    0.5000    0.0000 C   0  0  3  0  0  0  0  0  0  0  0  0<br>    2.8660   -0.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    0.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -1.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -1.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    2.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -2.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -2.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -2.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.4682    1.4250    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    1.3500    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2881   -0.0369    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350    0.1900    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.9081    1.0369    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.1951    2.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -0.6900    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -0.6900    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    1.6200    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.9081    1.9631    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350    2.8100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2881    3.0369    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -2.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -2.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -3.1200    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  4  1  0  0  0  0<br>  1 21  1  0  0  0  0<br>  2  3  1  0  0  0  0<br>  2  9  1  0  0  0  0<br>  2 18  1  0  0  0  0<br>  3  4  1  0  0  0  0<br>  3  6  1  0  0  0  0<br>  3 13  1  0  0  0  0<br>  4  5  1  0  0  0  0<br>  4 14  1  0  0  0  0<br>  5  7  2  0  0  0  0<br>  5  8  1  0  0  0  0<br>  6 15  1  0  0  0  0<br>  6 16  1  0  0  0  0<br>  6 17  1  0  0  0  0<br>  7 10  1  0  0  0  0<br>  7 19  1  0  0  0  0<br>  8 11  2  0  0  0  0<br>  8 20  1  0  0  0  0<br>  9 22  1  0  0  0  0<br>  9 23  1  0  0  0  0<br>  9 24  1  0  0  0  0<br> 10 12  2  0  0  0  0<br> 10 25  1  0  0  0  0<br> 11 12  1  0  0  0  0<br> 11 26  1  0  0  0  0<br> 12 27  1  0  0  0  0<br>M  END
Compound Name

Ephedrine

CID

5032

Molecular Formula

C10H15NO

Molecular Weight

165

No. Hydrogen Bond Acceptors

2

No. Hydrogen Bond Donors

2

Similar Applications

Chiral

Chiral Amphetamines with Ephedrines & Pseudoephedrines on Lux 3µm AMP 150x3mm

Lux 3 µm AMP, LC Column 150 x 3.0 mm, EA

23640

Reversed Phase

Extraction of Amphetamines-NIDA5 Using Strata X-C on Kinetex 2.6µm C18 50 x 2.1mm by LCMS

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

18845

Application Specific

Alternative amphetamines by MSD on a ZB-Drug1

Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea

18490

Application Specific

Expanded amphetamines and interferences including TFMPP by MSD on a ZB-Drug1

Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea

18039

Expanded Amphetamines and Interferences by MSD on a ZB-5MSi

17933

Application Specific

Expanded Amphetamines and Interferences by MSD on a ZB-Drug-1

Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea

17932

Reversed Phase

Extraction of Amphetamines on Strata-X-C

Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea

17192

Drug mixture extracted from Plasma using PPT

15587

Catecholamines on Onyx C18

15480

Standard

Drugs of Abuse

Zebron ZB-1, GC Cap. Column 15 m x 0.53 mm x 0.50 µm, Ea

1080