Temazepam on Lux Cellulose-2

Temazepam on Lux Cellulose-2
LC Conditions
Column

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

Brand

Lux

Part No

00G-4457-E0

Phase Name

Cellulose-2

Elution Type

Isocratic

Mobile Phase

A: 0.1% DEA in Acetonitrile

B: 0.1% DEA in Isopropanol

Gradient Profile

Step No.

Time(min)

%A

%B

1

10

95

5

Flow Rate

1.00 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-2, 4 x 3.0mm, 10/Pk Part No.: AJ0-8366 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
00G-4457-E0

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

View Product

  • 1. Temazepam
  • 2. Temazepam
-OEChem-06211003152D<br><br> 34 36  0     1  0  0  0  0  0999 V2000<br>    8.1647    0.0492    0.0000 Cl  0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3100   -0.9749    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.1204   -2.6577    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.7188   -2.0984    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7439   -0.0740    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.5006   -1.4749    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.5006   -0.4749    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.7188    0.1486    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.3100   -0.9749    0.0000 C   0  0  3  0  0  0  0  0  0  0  0  0<br>    3.7439   -1.8759    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.9413    1.1235    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3946    0.0597    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3946   -2.0096    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.9413   -3.0734    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.3006   -0.4541    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.3006   -1.4957    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2083    1.8037    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.8969    1.4182    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.4308    2.7786    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.1194    2.3932    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.3864    3.0734    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8578   -0.2552    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3874    0.6797    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3874   -2.6296    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.3369   -3.2113    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.0793   -3.6778    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.5458   -2.9354    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.8364   -1.8078    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.6158    1.6209    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3514    0.9965    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.9763    3.2003    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.7119    2.5759    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -0.4380    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.5243    3.6778    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1 15  1  0  0  0  0<br>  2  9  1  0  0  0  0<br>  2 33  1  0  0  0  0<br>  3 10  2  0  0  0  0<br>  4  6  1  0  0  0  0<br>  4 10  1  0  0  0  0<br>  4 14  1  0  0  0  0<br>  5  8  2  0  0  0  0<br>  5  9  1  0  0  0  0<br>  6  7  2  0  0  0  0<br>  6 13  1  0  0  0  0<br>  7  8  1  0  0  0  0<br>  7 12  1  0  0  0  0<br>  8 11  1  0  0  0  0<br>  9 10  1  0  0  0  0<br>  9 22  1  0  0  0  0<br> 11 17  2  0  0  0  0<br> 11 18  1  0  0  0  0<br> 12 15  2  0  0  0  0<br> 12 23  1  0  0  0  0<br> 13 16  2  0  0  0  0<br> 13 24  1  0  0  0  0<br> 14 25  1  0  0  0  0<br> 14 26  1  0  0  0  0<br> 14 27  1  0  0  0  0<br> 15 16  1  0  0  0  0<br> 16 28  1  0  0  0  0<br> 17 19  1  0  0  0  0<br> 17 29  1  0  0  0  0<br> 18 20  2  0  0  0  0<br> 18 30  1  0  0  0  0<br> 19 21  2  0  0  0  0<br> 19 31  1  0  0  0  0<br> 20 21  1  0  0  0  0<br> 20 32  1  0  0  0  0<br> 21 34  1  0  0  0  0<br>M  END
Compound Name

Temazepam

CID

5391

Molecular Formula

C16H13ClN2O2

Molecular Weight

300

No. Hydrogen Bond Acceptors

3

No. Hydrogen Bond Donors

1

Similar Applications

Reversed Phase

7.5 min Pain Panel on Kinetex 2.6µm Biphenyl, 30x2.1mm ESI+

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 30 x 2.1 mm, Ea

23560

Reversed Phase

Drugs of Abuse by LCMS using Kinetex 1.7u Biphenyl 50x2.1mm

Kinetex 1.7 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea

23445

Reversed Phase

Drugs of Abuse by LCMS using Kinetex 1.7u EVO C18 50x2.1mm

Kinetex 1.7 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, Ea

23444

Reversed Phase

Full Pain Panel using Kinetex 2.6u Biphenyl 50x2.1mm

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea

22122

Reversed Phase

Fast Pain Panel using Kinetex 2.6 u Biphenyl 50x3.0mm

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea

22121

Reversed Phase

Full Pain Panel using Kinetex 5um Biphenyl 50x3.0mm

Kinetex 5 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea

22120

Reversed Phase

Pain Panel Benzodiazapines using Kinetex 2.6u Biphenyl 50x3.0mm

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea

22109

Reversed Phase

Full Pain Panel using Kinetex 2.6u Biphenyl 50x3.0mm

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea

22104

Chiral

Temazepam on Lux 5µm Cellulose-1 in RP

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

20236

Chiral

Temazepam on Lux 5µm Cellulose-4 in RP

Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea

20188

Temazepam Lux 5 µm Amylose-2 250 x 4.6mm in PO-90%MeOH

18140

Chiral

Temazepam on Lux 5 µm Cellulose-2 250 x 4.6mm ID in PO-90%MeOH

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

18139

Chiral

Temazepam on Lux 5µ Cellulose-1 250 x 4.6mm in NP

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

17665

Chiral

Temazepam on Lux Cellulose-2

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

17416

Chiral

Temazepam on Lux Cellulose-1

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

17415