Temazepam on Lux Cellulose-2
LC Conditions
Column
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4457-E0
Phase Name
Cellulose-2
Elution Type
Isocratic
Mobile Phase
A: 0.1% DEA in Acetonitrile
B: 0.1% DEA in Isopropanol
Gradient Profile
Step No.
Time(min)
%A
%B
1
10
95
5
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-2, 4 x 3.0mm, 10/Pk Part No.: AJ0-8366 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Temazepam
- 2. Temazepam
-OEChem-06211003152D<br><br> 34 36 0 1 0 0 0 0 0999 V2000<br> 8.1647 0.0492 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3100 -0.9749 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1204 -2.6577 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7188 -2.0984 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7439 -0.0740 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5006 -1.4749 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5006 -0.4749 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7188 0.1486 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.3100 -0.9749 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 3.7439 -1.8759 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9413 1.1235 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3946 0.0597 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3946 -2.0096 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9413 -3.0734 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3006 -0.4541 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3006 -1.4957 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2083 1.8037 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.8969 1.4182 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.4308 2.7786 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.1194 2.3932 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.3864 3.0734 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8578 -0.2552 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3874 0.6797 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3874 -2.6296 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3369 -3.2113 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.0793 -3.6778 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5458 -2.9354 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.8364 -1.8078 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.6158 1.6209 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3514 0.9965 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.9763 3.2003 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7119 2.5759 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.4380 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5243 3.6778 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 15 1 0 0 0 0<br> 2 9 1 0 0 0 0<br> 2 33 1 0 0 0 0<br> 3 10 2 0 0 0 0<br> 4 6 1 0 0 0 0<br> 4 10 1 0 0 0 0<br> 4 14 1 0 0 0 0<br> 5 8 2 0 0 0 0<br> 5 9 1 0 0 0 0<br> 6 7 2 0 0 0 0<br> 6 13 1 0 0 0 0<br> 7 8 1 0 0 0 0<br> 7 12 1 0 0 0 0<br> 8 11 1 0 0 0 0<br> 9 10 1 0 0 0 0<br> 9 22 1 0 0 0 0<br> 11 17 2 0 0 0 0<br> 11 18 1 0 0 0 0<br> 12 15 2 0 0 0 0<br> 12 23 1 0 0 0 0<br> 13 16 2 0 0 0 0<br> 13 24 1 0 0 0 0<br> 14 25 1 0 0 0 0<br> 14 26 1 0 0 0 0<br> 14 27 1 0 0 0 0<br> 15 16 1 0 0 0 0<br> 16 28 1 0 0 0 0<br> 17 19 1 0 0 0 0<br> 17 29 1 0 0 0 0<br> 18 20 2 0 0 0 0<br> 18 30 1 0 0 0 0<br> 19 21 2 0 0 0 0<br> 19 31 1 0 0 0 0<br> 20 21 1 0 0 0 0<br> 20 32 1 0 0 0 0<br> 21 34 1 0 0 0 0<br>M END
Compound Name
Temazepam
CID
5391
Molecular Formula
C16H13ClN2O2
Molecular Weight
300
No. Hydrogen Bond Acceptors
3
No. Hydrogen Bond Donors
1
Similar Applications
Reversed Phase
7.5 min Pain Panel on Kinetex 2.6µm Biphenyl, 30x2.1mm ESI+
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 30 x 2.1 mm, Ea
23560
Reversed Phase
Drugs of Abuse by LCMS using Kinetex 1.7u Biphenyl 50x2.1mm
Kinetex 1.7 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea
23445
Reversed Phase
Drugs of Abuse by LCMS using Kinetex 1.7u EVO C18 50x2.1mm
Kinetex 1.7 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, Ea
23444
Reversed Phase
Full Pain Panel using Kinetex 2.6u Biphenyl 50x2.1mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea
22122
Reversed Phase
Fast Pain Panel using Kinetex 2.6 u Biphenyl 50x3.0mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22121
Reversed Phase
Full Pain Panel using Kinetex 5um Biphenyl 50x3.0mm
Kinetex 5 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22120
Reversed Phase
Pain Panel Benzodiazapines using Kinetex 2.6u Biphenyl 50x3.0mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22109
Reversed Phase
Full Pain Panel using Kinetex 2.6u Biphenyl 50x3.0mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22104
Chiral
Temazepam on Lux 5µm Cellulose-1 in RP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
20236
Chiral
Temazepam on Lux 5µm Cellulose-4 in RP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
20188
Temazepam Lux 5 µm Amylose-2 250 x 4.6mm in PO-90%MeOH
18140
Chiral
Temazepam on Lux 5 µm Cellulose-2 250 x 4.6mm ID in PO-90%MeOH
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
18139
Chiral
Temazepam on Lux 5µ Cellulose-1 250 x 4.6mm in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17665
Chiral
Temazepam on Lux Cellulose-2
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17416
Chiral
Temazepam on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17415