Nitrogen and Phosphorous Pesticides (EPA 507) Mix # 5 on ZB-MR2

Nitrogen and Phosphorous Pesticides (EPA 507) Mix # 5 on ZB-MR2
GC Conditions
Official Method

EPA 507

Column

Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.25 mm x 0.20 µm, Ea

Part No

7HG-G017-10

Phase Name

ZB-MultiResidue-2

Injection

On-Column @ 43°C

Carrier Gas

Constant Flow Helium, 0.8 mL/min

Detection

Mass Selective (MSD) @ (335°C)

Detection Info
Sample Notes

Analytes 10 ppm in Acetone

Order Items Used in This Application

Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.25 mm x 0.20 µm, Ea
7HG-G017-10

Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.25 mm x 0.20 µm, Ea

View Product

  • 1. Dichlorvos
  • 2. Pebulate
  • 3. Terbacil
  • 4. Simetryn
  • 5. Napropamide
  • 6. Fenarimol
  • 7. Fluridone
-OEChem-06211003152D<br><br> 18 17  0     0  0  0  0  0  0999 V2000<br>    7.1962   -0.4330    0.0000 Cl  0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3301    1.0670    0.0000 Cl  0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -0.4330    0.0000 P   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -0.9330    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.2320    0.4330    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    0.0670    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2320   -1.2990    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -0.4330    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    1.2990    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641   -0.4330    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3301    0.0670    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3100    0.1039    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -0.1230    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.6900   -0.9699    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690    0.9890    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.0420    1.8360    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.1951    1.6090    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641   -1.0530    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1 11  1  0  0  0  0<br>  2 11  1  0  0  0  0<br>  3  4  1  0  0  0  0<br>  3  5  1  0  0  0  0<br>  3  6  1  0  0  0  0<br>  3  7  2  0  0  0  0<br>  4  8  1  0  0  0  0<br>  5  9  1  0  0  0  0<br>  6 10  1  0  0  0  0<br>  8 12  1  0  0  0  0<br>  8 13  1  0  0  0  0<br>  8 14  1  0  0  0  0<br>  9 15  1  0  0  0  0<br>  9 16  1  0  0  0  0<br>  9 17  1  0  0  0  0<br> 10 11  2  0  0  0  0<br> 10 18  1  0  0  0  0<br>M  END
Compound Name

Dichlorvos

CID

3039

Molecular Formula

C4H7Cl2O4P

Molecular Weight

220

No. Hydrogen Bond Acceptors

4

Similar Applications

Reversed Phase

Cannabis pesticide screening using Kinetex 2.6um Polar C18 50x4.6mm

Kinetex 2.6 µm Polar C18 100 Å, LC Column 50 x 4.6 mm, Ea

24145

Reversed Phase

Cannabis pesticide screening using Luna Omega 3um Polar C18 50x4.6mm

Luna Omega 3 µm Polar C18 100 Å, LC Column 50 x 4.6 mm, Ea

24144

Application Specific

EPA Method 525.2 on ZB-SemiVolatiles

Zebron ZB-SemiVolatiles, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

21438

Reversed Phase

Screening >350 Pesticides from Food & Feed According to Regulation (EC) No. 396/2005

Synergi 2.5 µm Fusion-RP 100 Å, LC Column 50 x 2 mm, Ea

20924

Quechers [AOAC-GCMS] - Lettuce extract, ZB-5MSi 30x0.25x0.25mm

20826

Quechers [AOAC-GCMS] - Grapes extract, ZB-5MSi 30x0.25x0.25mm

20825

Quechers [EN-GCMS] - Lettuce extract, ZB-5MSi 30x0.25x0.25mm

20824

Quechers(AOAC-GCMS)- Apple extract, ZB-5MSi 30x0.25x0.25mm

20755

Reversed Phase

Quantification of Organophosphorus Pesticides by QuEchERS and LC/MS/MS

Synergi 4 µm Fusion-RP 80 Å, LC Column 50 x 2 mm, Ea

20020

Application Specific

Organophosphorous Pesticides (EPA 8141) Mix # 1 on ZB-MR2

Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.25 mm x 0.20 µm, Ea

17581

Application Specific

Screening of Pesticides by GC-MS on ZB-MultiResidue-1

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16184

Application Specific

Screening of Pesticide by GC/MS on ZB-MR2

Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.25 mm x 0.20 µm, Ea

16183

Application Specific

EPA 8141: Organophosphorous Pesticides on ZB-MR2

Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea

16182

Application Specific

EPA 8141: Organophosphorous Pesticides on ZB-MR1

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea

16181

Application Specific

European Red List Organophosphate Pesticides on Zebron ZB-1701P 30m x 0.25mm x 0.25um

Zebron ZB-1701P, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

15864

Standard

Nitrogen and Phosphorous Pesticides - EPA Method 507 on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

15445

Standard

Nitrogen and Phosphorous Pesticides on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

15444

Standard

EPA Method 8141A on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

15438

Standard

Organophosphorous Pesticides on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

15437

Standard

EPA Method 525.2: Organic compounds in Drinking Water on ZB-5 on ZB-5

Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14771