Axia Packed Gemini-NX 5 µm C18 (low pH loading - 3 component mix - 106mg/140µL)
LC Conditions
Column
Gemini 5 µm NX-C18 110 Å, LC Column 50 x 21.2 mm, AXIA Packed, Ea
Brand
Gemini
Part No
00B-4454-P0-AX
Phase Name
NX-C18
Elution Type
Gradient
Mobile Phase
A: 0.5 % TFA in Water
B: Acetonitrile
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
95
5
2
5
5
95
Flow Rate
30.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard PREP Cartridge, Gemini-NX C18 15 x 21.2mm, Ea Part No.: AJ0-8370 - Holder Part No.: AJ0-8223
Order Items Used in This Application
- 1. Diphenhydramine
- 2. Oxybutynin
- 3. Terfenadine
-OEChem-06211003152D<br><br> 40 41 0 0 0 0 0 0 0999 V2000<br> 3.7320 0.2500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 2.7500 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 3.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 3.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -3.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 0.3700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3426 1.1423 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.9441 1.8326 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.2554 1.8577 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.6540 1.1674 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1951 -1.4400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -0.8700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 -1.4400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9272 1.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3100 3.7869 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 3.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.6900 2.7131 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0420 2.7131 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 3.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4220 3.7869 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1951 -3.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7331 -0.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 -3.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 2.3700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -3.8700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7331 1.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 3 1 0 0 0 0<br> 1 6 1 0 0 0 0<br> 2 7 1 0 0 0 0<br> 2 12 1 0 0 0 0<br> 2 13 1 0 0 0 0<br> 3 4 1 0 0 0 0<br> 3 5 1 0 0 0 0<br> 3 20 1 0 0 0 0<br> 4 8 2 0 0 0 0<br> 4 10 1 0 0 0 0<br> 5 9 2 0 0 0 0<br> 5 11 1 0 0 0 0<br> 6 7 1 0 0 0 0<br> 6 21 1 0 0 0 0<br> 6 22 1 0 0 0 0<br> 7 23 1 0 0 0 0<br> 7 24 1 0 0 0 0<br> 8 14 1 0 0 0 0<br> 8 25 1 0 0 0 0<br> 9 15 1 0 0 0 0<br> 9 26 1 0 0 0 0<br> 10 16 2 0 0 0 0<br> 10 27 1 0 0 0 0<br> 11 17 2 0 0 0 0<br> 11 28 1 0 0 0 0<br> 12 29 1 0 0 0 0<br> 12 30 1 0 0 0 0<br> 12 31 1 0 0 0 0<br> 13 32 1 0 0 0 0<br> 13 33 1 0 0 0 0<br> 13 34 1 0 0 0 0<br> 14 18 2 0 0 0 0<br> 14 35 1 0 0 0 0<br> 15 19 2 0 0 0 0<br> 15 36 1 0 0 0 0<br> 16 18 1 0 0 0 0<br> 16 37 1 0 0 0 0<br> 17 19 1 0 0 0 0<br> 17 38 1 0 0 0 0<br> 18 39 1 0 0 0 0<br> 19 40 1 0 0 0 0<br>M END
Compound Name
Diphenhydramine
CID
3100
Molecular Formula
C17H21NO
Molecular Weight
255
No. Hydrogen Bond Acceptors
2
Similar Applications
Reversed Phase
Pill Screen on Verex and Whatman Filter Vials (Pill 1 - Benadryl)
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 100 x 4.6 mm, Ea
25593
Reversed Phase
Diphenhydramine in Water/Acetonitrile (50:50) Filtered vs Unfiltered Samples
Kinetex 5 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea
25194
Reversed Phase
Cold Medications on Luna 3u Polar C18 100x4.6mm
Luna Omega 3 µm Polar C18 100 Å, LC Column 100 x 4.6 mm, Ea
24046
Reversed Phase
Cold medicine compounds on Kinetex 2.6 µm EVO C18
Kinetex 2.6 µm EVO C18 100 Å, LC Column 100 x 4.6 mm, EA
23036
Reversed Phase
Antihistamines on Kinetex 2.6u F5 50x4.6mm at pH 2.9 and pH 7.2
Kinetex 2.6 µm F5 100 Å, LC Column 50 x 4.6 mm, Ea
22838
Reversed Phase
ABN mix at low pH using Kinetex 5u EVO C18 150x4.6mm
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
22735
Reversed Phase
ABN mix at high pH using Kinetex 5u EVO C18 150x4.6mm
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
22733
Reversed Phase
ABN mix at neutral pH using Kinetex 5u EVO C18 150x4.6mm
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
22732
Reversed Phase
Pharmaceutical drug mix using Kinetex 5u C18 100x4.6mm
Kinetex 5 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea
20885
Reversed Phase
KNX 5 Brochure - Pharma mix analysis using Kinetex 5um C18 150x4.6mm
Kinetex 5 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
20738
Application Specific
Drug screen by MSD on a ZB-Drug1
Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea
18175