Benzoin on Lux 3u Cellulose-2 by SFC
LC Conditions
Column
Lux 3 µm Cellulose-2, LC Column 50 x 4.6 mm, Ea
Brand
Lux
Part No
00B-4456-E0
Phase Name
Cellulose-2
Elution Type
Isocratic
Mobile Phase
A: 0.1% DEA+0.1% TFA in methanol
B: CO2
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
15
85
Flow Rate
4.00 mL/min
Temperature
40°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-2, 4 x 3.0mm ID, 10/Pk Part No.: AJ0-8366 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Benzoin
-OEChem-06211003152D<br><br> 28 29 0 1 0 0 0 0 0999 V2000<br> 2.5369 0.2500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 -0.2500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 -0.2500 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 3.4030 -1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5369 -1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5369 -2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 -3.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 3.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 0.6000 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8059 -1.4400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -1.4400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 1.4400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6720 1.4400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8059 -3.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -3.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 -3.8700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 3.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6720 3.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 3.8700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 3 1 0 0 0 0<br> 1 25 1 0 0 0 0<br> 2 5 2 0 0 0 0<br> 3 4 1 0 0 0 0<br> 3 5 1 0 0 0 0<br> 3 17 1 0 0 0 0<br> 4 7 2 0 0 0 0<br> 4 8 1 0 0 0 0<br> 5 6 1 0 0 0 0<br> 6 9 2 0 0 0 0<br> 6 10 1 0 0 0 0<br> 7 11 1 0 0 0 0<br> 7 18 1 0 0 0 0<br> 8 12 2 0 0 0 0<br> 8 19 1 0 0 0 0<br> 9 14 1 0 0 0 0<br> 9 20 1 0 0 0 0<br> 10 15 2 0 0 0 0<br> 10 21 1 0 0 0 0<br> 11 13 2 0 0 0 0<br> 11 22 1 0 0 0 0<br> 12 13 1 0 0 0 0<br> 12 23 1 0 0 0 0<br> 13 24 1 0 0 0 0<br> 14 16 2 0 0 0 0<br> 14 26 1 0 0 0 0<br> 15 16 1 0 0 0 0<br> 15 27 1 0 0 0 0<br> 16 28 1 0 0 0 0<br>M END
Compound Name
Benzoin
CID
8400
Molecular Formula
C14H12O2
Molecular Weight
212
No. Hydrogen Bond Acceptors
2
No. Hydrogen Bond Donors
1
Similar Applications
Chiral
Benzoin on Lux 5µm Cellulose-1 in RP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
20207
Chiral
Benzoin on Lux 5µm Cellulose-4 in NP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
20166
Chiral
Benzoin on Lux 5µm Cellulose-4 in RP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
20143
Chiral
Benzoin on Lux 5µm Cellulose-2 in NP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20116
Benzoin on Lux 5µm Amylose-2 in NP
20083
Chiral
Benzoin on Lux 3u Cellulose-2 by SFC
Lux 3 µm Cellulose-2, LC Column 50 x 4.6 mm, Ea
18211
Chiral
Benzoin on Lux 5u Cellulose-2 by SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
18210
Chiral
Benzoin on Lux 5u Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
18209