SRM 870 Acquity UPLC - Kinetex 2.6µm C18 50 x 4.6mm ID (2 mL/min)

SRM 870 Acquity UPLC - Kinetex 2.6µm C18 50 x 4.6mm ID (2 mL/min)
LC Conditions
Column

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 4.6 mm, Ea

Brand

Kinetex

Part No

00B-4462-E0

Phase Name

C18

Elution Type

Isocratic

Mobile Phase

A: 20 mM KH2PO4

B: Methanol

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

20

80

Flow Rate

2.00 mL/min

Temperature

0°C

Detection

UV-Vis Abs.-Diode Array (PDA) @ (25°C)

Detection Info

Order Items Used in This Application

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 4.6 mm, Ea
00B-4462-E0

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 4.6 mm, Ea

View Product

  • 1. Toluene
  • 2. Ethylbenzene
  • 3. Quinizarine
  • 4. Amitriptyline
-OEChem-06211003142D<br><br> 15 15  0     0  0  0  0  0  0999 V2000<br>    2.8660    0.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    0.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    0.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    1.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -1.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -1.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -1.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631    0.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690    0.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4860    1.5000    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    2.1200    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.2460    1.5000    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -1.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -1.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -2.1200    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  2  2  0  0  0  0<br>  1  3  1  0  0  0  0<br>  1  4  1  0  0  0  0<br>  2  5  1  0  0  0  0<br>  2  8  1  0  0  0  0<br>  3  6  2  0  0  0  0<br>  3  9  1  0  0  0  0<br>  4 10  1  0  0  0  0<br>  4 11  1  0  0  0  0<br>  4 12  1  0  0  0  0<br>  5  7  2  0  0  0  0<br>  5 13  1  0  0  0  0<br>  6  7  1  0  0  0  0<br>  6 14  1  0  0  0  0<br>  7 15  1  0  0  0  0<br>M  END
Compound Name

Toluene

CID

1140

Molecular Formula

C7H8

Molecular Weight

92

Similar Applications

Hydrophilic Interaction

HILIC Separation of water-soluble vitamins

Luna Omega 3µm HILIC 100Å, LC Column 150 x 4.6 mm, ea

28699

Hydrophilic Interaction

HILIC Separation of Catecholamines

Luna Omega 3µm HILIC 100Å, LC Column 150 x 4.6 mm, ea

28692

Improved Performance

Separation of Residual Solvent Critical Pairs in Less than 15 min using Zebron ZB-624PLUS GC column (APP ID 24776)

Zebron ZB-624plus, GC Cap. Column 30m x 0.32mm x 1.8um, Ea

25983

Reversed Phase

Alkylsulfonate Esters on Luna Omega Polar C18 - TFA

Luna Omega 1.6µm Polar C18 100Å, LC Column 50 x 2.1 mm, EA

25640

Reversed Phase

5a) Sulfonic Acid Esters on Luna Omega Polar C18 - formic acid

Luna Omega 1.6µm Polar C18 100Å, LC Column 50 x 2.1 mm, EA

25604

Reversed Phase

4b) Sulfonic Acid Esters on Luna Omega Polar C18 - ammonium formate

Luna Omega 1.6µm Polar C18 100Å, LC Column 50 x 2.1 mm, EA

25602

Application Specific

ASTM 6730 on ZB-PONA 100m x 0.25mm x 0.5um with ZB-PONA tuning 5m x 0.25mm x 1.0mm

Zebron ZB-DHA-PONA, GC Cap. Column 100m x 0.25mm x 0.5µm, Ea

25558

Application Specific

Aromatics Marker Standards on ZB-DHA-PONA 100m x 0.25mm x 0.5um

Zebron ZB-DHA-PONA, GC Cap. Column 100m x 0.25mm x 0.5µm, Ea

25309

Reversed Phase

EPA 8330B on Kinetex 2.6u Polar C18 100x4.6mm

Kinetex 2.6 µm Polar C18 100 Å, LC Column 100 x 4.6 mm, Ea

24158

Reversed Phase

EPA 8330A on Kinetex 2.6u Polar C18 100x4.6mm

Kinetex 2.6 µm Polar C18 100 Å, LC Column 100 x 4.6 mm, Ea

24157

Reversed Phase

Explosives Mix on Kinetex 5u EVO C18 150x4.6mm

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

23094

Reversed Phase

Carcinogenic amines on Kinetex 2.6 µm EVO C18

Kinetex 2.6 µm EVO C18 100 Å, LC Column 150 x 2.1 mm, EA

23042

Reversed Phase

Customer high pH study using Kinetex 5u EVO C18 150x4.6mm

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

22731

Application Specific

EPA Method 525.2 on ZB-SemiVolatiles

Zebron ZB-SemiVolatiles, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

21438

Application Specific

EPA Method 8270D on Zebron ZB-SemiVolatiles

Zebron ZB-SemiVolatiles, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

20582

Application Specific

Fast EPA Method 8270D on Zebron ZB-SemiVolatiles

Zebron ZB-SemiVolatiles, GC Cap. Column 20 m x 0.18 mm x 0.36 µm, Ea

20572

Reversed Phase

Aeris Batch Reproducalbity #3: SRM 870 on Aeris PEPTIDE 1.7u XB-C18 50x4.6mm

Aeris 1.7 µm PEPTIDE XB-C18 100 Å, LC Column 50 x 2.1 mm, Ea

19909

Reversed Phase

Aeris WIDEPORE 3.6u XB-C18 150 x 2.1mm ID QC Chromatogram (AL0-8931)

Aeris 3.6 µm WIDEPORE XB-C18 200 Å, LC Column 150 x 2.1 mm, Ea

19812

Reversed Phase

Aeris 3.6u XB-C8 150 x 2.1mm ID QC Chromatogram (AL0-8931)

Aeris 3.6 µm WIDEPORE XB-C8 200 Å, LC Column 150 x 2.1 mm, Ea

19811

Reversed Phase

Aeris 3.6u C4 150 x 2.1mm ID QC Chromatogram (AL0-8931)

Aeris 3.6 µm WIDEPORE C4 200 Å, LC Column 150 x 2.1 mm, Ea

19810

Reversed Phase

SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm With KrudKatcher

Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea

18803

Reversed Phase

SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm With Cartridge

Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea

18802

Reversed Phase

SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm Without Cartridge

Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea

18801

High Temperature

EPA Method 8270C: Semivolatile Organics on ZB-XLB-HT

Zebron ZB-XLB-HT, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

18785

Reversed Phase

EPA Method 8330: Explosive Mix Using Luna Phenyl Hexyl

Luna 5 µm Phenyl-Hexyl 100 Å, LC Column 250 x 4.6 mm, Ea

18152

Reversed Phase

EPA Method 8330: Explosive Mix Using Synergi Hydro-RP

Synergi 4 µm Hydro-RP 80 Å, LC Column 250 x 4.6 mm, Ea

18151

Reversed Phase

EPA Method 8330: Explosive Mix Using Synergi Hydro-RP

Synergi 4 µm Hydro-RP 80 Å, LC Column 250 x 4.6 mm, Ea

18149

Reversed Phase

EPA Method 8330: Explosive Mix Using Luna Phenyl Hexyl

Luna 5 µm Phenyl-Hexyl 100 Å, LC Column 250 x 4.6 mm, Ea

18148

Reversed Phase

EPA Method 8330: Explosive Mix Using Luna Phenyl Hexyl

Luna 5 µm Phenyl-Hexyl 100 Å, LC Column 250 x 4.6 mm, Ea

18147

Reversed Phase

EPA Method 8330: Explosive Mix Using Synergi Hydro-RP

Synergi 4 µm Hydro-RP 80 Å, LC Column 250 x 4.6 mm, Ea

18146

Reversed Phase

EPA Method 8330: Explosive Mix Using Synergi Hydro-RP

Synergi 4 µm Hydro-RP 80 Å, LC Column 250 x 4.6 mm, Ea

18145

Reversed Phase

EPA Method 8330: Explosive Mix Using Luna 3u Phenyl Hexyl

Luna 3 µm Phenyl-Hexyl 100 Å, LC Column 50 x 2 mm, Ea

17981

Reversed Phase

EPA Method 8330: Explosive Mix Using Synergi 2.5u Hydro Rp

Synergi 2.5 µm Hydro-RP 100 Å, LC Column 100 x 2 mm, Ea

17980

Reversed Phase

EPA Method 8330: Explosive Mix Using Synergi 2.5u Polar Rp

Synergi 2.5 µm Polar-RP 100 Å, LC Column 100 x 2 mm, Ea

17979

Reversed Phase

EPA Method 8330: Explosive Mix Using Gemini 5u NX

Gemini 5 µm NX-C18 110 Å, LC Column 250 x 4.6 mm, Ea

17959

Normal Phase

EPA Method 8330: Explosive Mix Using Hyperclone 5u CN

HyperClone 5 µm CN (CPS) 120 Å, LC Column 250 x 4.6 mm, Ea

17958

Reversed Phase

EPA Method 8330: Explosive Mix Using Gemini C6 Phenyl

Gemini 5 µm C6-Phenyl 110 Å, LC Column 250 x 4.6 mm, Ea

17957

Reversed Phase

EPA Method 8330: Explosive Mix Using Hyperclone ODS C18

HyperClone 5 µm ODS (C18) 120 Å, LC Column 250 x 4.6 mm, Ea

17956

Normal Phase

EPA Method 8330: Explosive mix Using Luna 5u CN

Luna 5 µm CN 100 Å, LC Column 250 x 4.6 mm, Ea

17955

Reversed Phase

EPA Method 8330: Explosive Mix Using Luna 5u PFP

Luna 5 µm PFP(2) 100 Å, LC Column 250 x 4.6 mm, Ea

17954

Reversed Phase

EPA Method 8330: Explosive Mix Using Gemini 5u C18

Gemini 5 µm C18 110 Å, LC Column 250 x 4.6 mm, Ea

17953

Reversed Phase

EPA Method 8330: Explosive Mix Using Luna 5u C18

Luna 5 µm C18(2) 100 Å, LC Column 250 x 4.6 mm, Ea

17952

Reversed Phase

EPA Method 8330: Explosive Mix Using Synergi Polar RP

Synergi 4 µm Polar-RP 80 Å, LC Column 250 x 4.6 mm, Ea

17951

Reversed Phase

EPA Method 8330: Explosive Mix Using Luna Phenyl Hexyl

Luna 5 µm Phenyl-Hexyl 100 Å, LC Column 250 x 4.6 mm, Ea

17913

Reversed Phase

EPA Method 8330: Explosive Mix Using Synergi Hydro-RP

Synergi 4 µm Hydro-RP 80 Å, LC Column 250 x 4.6 mm, Ea

17912

Standard

Bioethanol by MSD on a ZB-1

Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea

16657

Application Specific

Bioethanol by MSD on ZB-Bioethanol

Zebron ZB-Bioethanol, GC Cap. Column 30 m x 0.25 mm x 1.00 µm, Ea

16654

Standard

EPA Method 8270C on ZB-XLB

Zebron ZB-XLB, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16584

EPA Method 8270C ZB-5MSi

16413

Improved Performance

USP 467 Procedure B - Class 2 Mix A by GC/FID on ZB-WAXplus

Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea

16353

Standard

USP 467 Procedure A - Class 2 Mix A by GC/FID on ZB-624

Zebron ZB-624, GC Cap. Column 30 m x 0.32 mm x 1.80 µm, Ea

16349

Application Specific

EPA Method 8270C on ZB-MR1

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16275

Application Specific

BTEXs on ZB-MR1

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16254

Application Specific

BTEXs on ZB-MR2

Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.25 mm x 0.20 µm, Ea

16253

Standard

Benzene Toluene Common Co-elutersl on ZB-1

Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea

16252

Standard

ASTM Method D3798: Analysis of p-Xylene on ZB-WAX

Zebron ZB-WAX, GC Cap. Column 30 m x 0.25 mm x 0.50 µm, Ea

16219

Standard

ASTM Method D3798: Analysis of p-Xylene on ZB-WAX

Zebron ZB-WAX, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea

16218

Standard

ASTM Method D5060: Determining Impurities in High Purity Ethylbenzene on ZB-FFAP

Zebron ZB-FFAP, GC Cap. Column 50 m x 0.32 mm x 0.50 µm, Ea

16145

Standard

ASTM Method D5135-95: Impurities in Styrene (Fast Analysis) on ZB-WAX

Zebron ZB-WAX, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea

16143

Standard

ASTM Method D5135-95: Analysis of Styrene on ZB-WAX

Zebron ZB-WAX, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea

16142

Standard

ASTM Method D2306-96: Universal Aromatic Solvent Analysis on ZB-WAX

Zebron ZB-WAX, GC Cap. Column 60 m x 0.32 mm x 0.50 µm, Ea

16141

Improved Performance

ASTM Method D5135-95: Solvent Analysis on ZB-WAXplus

Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16140

Standard

ASTM Method D5135-95: Solvent Analysis on ZB-WAX

Zebron ZB-WAX, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16139

Standard

Common Solvents on ZB-624

Zebron ZB-624, GC Cap. Column 20 m x 0.18 mm x 1.00 µm, Ea

15954

Standard

Common Solvents on ZB-FFAP

Zebron ZB-FFAP, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

15953

Standard

Common Solvents on ZB-WAX

Zebron ZB-WAX, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

15952

Common Solvents on ZB-1MS

15951

Improved Performance

Solvents on ZB-WAXplus 30x0.25x0.25

Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

15926

Standard

EPA Method 8260 - Volatile Organic Analysis on Zebron ZB-624 20m x 0.18mm x 1.00um

Zebron ZB-624, GC Cap. Column 20 m x 0.18 mm x 1.00 µm, Ea

15866

Improved Performance

p-Xylene Purity on ZB-WAX Plus 30m x 0.53mm x 1.00um

Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.53 mm x 1.00 µm, Ea

15865

Improved Performance

ASTM D5135-95: Styrene Impurities on ZB-WAXplus

Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

15815

Improved Performance

p-Xylene Purity on ZB-WAX Plus 30x0.25x0.25

Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

15810

Standard

Massachusetts EPH - Aliphatic Fraction on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea

15787

Standard

EPA Method 8260B: Volatile Organic Analysis on ZB-624

Zebron ZB-624, GC Cap. Column 20 m x 0.18 mm x 1.00 µm, Ea

15697

Standard

EPA Method 8270C: Semivolatile Organic Analysis on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.32 µm, Ea

15696

Standard

EPA Method 8270C: Semivolatile Organic Analysis on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea

15695

Standard

EPA Method 8270C on ZB-5MS 30x0.25x0.25

Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14953

Standard

EPA Method 8270C on Guardian on ZB-5

Zebron ZB-5 w/GUARDIAN, 5 m, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14945

Standard

p-Xylene Purity on ZB-WAX

Zebron ZB-WAX, GC Cap. Column 30 m x 0.53 mm x 1.00 µm, Ea

14941

Standard

Unleaded Gasoline - Pure on ZB-1

Zebron ZB-1, GC Cap. Column 60 m x 0.25 mm x 1.00 µm, Ea

14940

Standard

BTEX ZB-50 30x0.32x0.5

Zebron ZB-50, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea

14903

Standard

BTEX ZB5 30x0.32x0.25

Zebron ZB-5, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea

14902

Standard

BTEX in Under Six Minutes on ZB-WAX

Zebron ZB-WAX, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea

14895

Standard

Nitroaromatics - EPA Method 609: ZB-5 15x0.53x1.5

Zebron ZB-5, GC Cap. Column 15 m x 0.53 mm x 1.50 µm, Ea

14866

Standard

Abused Inhalants ZB-624 30x0.32x1.8

Zebron ZB-624, GC Cap. Column 30 m x 0.32 mm x 1.80 µm, Ea

14860

Standard

Abused Inhalants ZB-5 30x0.32x1.0

Zebron ZB-5, GC Cap. Column 30 m x 0.32 mm x 1.00 µm, Ea

14859

Standard

Abused Inhalants ZB-WAX 30x0.32x0.5

Zebron ZB-WAX, GC Cap. Column 30 m x 0.32 mm x 0.50 µm, Ea

14850

Standard

Industrial Solvents on ZB-WAX

Zebron ZB-WAX, GC Cap. Column 30 m x 0.53 mm x 1.00 µm, Ea

14809

Standard

Industrial Solvents on ZB-WAX 30x0.25x0.25

Zebron ZB-WAX, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14808

Standard

Industrial Solvents on ZB-624 60x0.32x1.8

Zebron ZB-624, GC Cap. Column 60 m x 0.32 mm x 1.80 µm, Ea

14807

Standard

PONA: Naphtha on ZB-1

Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea

14804

Standard

PONA: Retention Markers on ZB-1

Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea

14803

Standard

PONA: FCC on ZB-1

Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea

14802

Standard

PONA: Blended Fuel 1 on ZB-1

Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea

14801

Standard

PONA: Alkylate Fraction on ZB-1

Zebron ZB-1, GC Cap. Column 100 m x 0.25 mm x 0.50 µm, Ea

14800

Standard

EPA Method 8260: Volatile Organics on ZB-624

Zebron ZB-624, GC Cap. Column 60 m x 0.25 mm x 1.40 µm, Ea

14783

Standard

EPA Method 525.2: Organic compounds in Drinking Water on ZB-5 on ZB-5

Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14771

Reversed Phase

EPA Method 8330 Explosives mix using Synergi Polar-RP

Synergi 4 µm Polar-RP 80 Å, LC Column 250 x 4.6 mm, Ea

14769

Reversed Phase

EPA Method 8330 Explosives mix using Synergi Hydro-RP

Synergi 4 µm Hydro-RP 80 Å, LC Column 250 x 4.6 mm, Ea

14768

Standard

8270 Semi-Volatile Organic Analysis on ZB-5

Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14567