Extraction of Sulfa Drugs from Porcine Plasma using Strata X-C

Extraction of Sulfa Drugs from Porcine Plasma using Strata X-C
LC Conditions
Column

Synergi 4 µm Max-RP 80 Å, LC Column 150 x 4.6 mm, Ea

Brand

Synergi

Part No

00F-4337-E0

Phase Name

Max-RP

Elution Type

Gradient

Mobile Phase

A: 20 mm KH2PO4 (pH2.5)

B: ACN

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

95

5

2

15

20

80

Flow Rate

1.00 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, C12 4 x 3.0mm, 10/Pk Part No.: AJ0-6074 - Holder Part No.: KJ0-4282

Sample Preparation Details
Condition 1

1 mL Methanol at 1 mL/min

Condition 2

1 mL Water at 1 mL/min

Load

Load 1.50 mL Sample diluted in Water

Wash 1

1 mL HCl (0.1N) at 1 mL/min

Wash 2

1 mL Methanol at 1 mL/min

Dry

1 min at 10 of Hg

Elution 1

1 mL 5% Ammonium Hydroxide in Methanol at 1 mL/min

Evaporation

Evaporate to dryness

Reconstitute

200 µL KH2PO4 (20mM) pH 2.5

Order Items Used in This Application

Synergi 4 µm Max-RP 80 Å, LC Column 150 x 4.6 mm, Ea
00F-4337-E0

Synergi 4 µm Max-RP 80 Å, LC Column 150 x 4.6 mm, Ea

View Product

  • 1. Sulfanilamide
  • 2. Sulfathiazole
  • 3. Sulfamethoxazole
  • 4. Sulfaquinoxaline
-OEChem-06211003152D<br><br> 19 19  0     0  0  0  0  0  0999 V2000<br>    3.0000    1.5000    0.0000 S   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.0000    1.5000    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    1.5000    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.0000    2.5000    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.0000   -2.5000    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.0000    0.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.8660    0.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.1340    0.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.0000   -1.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.8660   -1.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.1340   -1.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.4030    0.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.5970    0.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.4030   -1.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.5970   -1.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.5369    2.8100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.4631    2.8100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.4631   -2.8100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.5369   -2.8100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  2  2  0  0  0  0<br>  1  3  2  0  0  0  0<br>  1  4  1  0  0  0  0<br>  1  6  1  0  0  0  0<br>  4 16  1  0  0  0  0<br>  4 17  1  0  0  0  0<br>  5  9  1  0  0  0  0<br>  5 18  1  0  0  0  0<br>  5 19  1  0  0  0  0<br>  6  7  2  0  0  0  0<br>  6  8  1  0  0  0  0<br>  7 10  1  0  0  0  0<br>  7 12  1  0  0  0  0<br>  8 11  2  0  0  0  0<br>  8 13  1  0  0  0  0<br>  9 10  2  0  0  0  0<br>  9 11  1  0  0  0  0<br> 10 14  1  0  0  0  0<br> 11 15  1  0  0  0  0<br>M  END
Compound Name

Sulfanilamide

CID

5333

Molecular Formula

C6H8N2O2S

Molecular Weight

172

No. Hydrogen Bond Acceptors

4

No. Hydrogen Bond Donors

2

Similar Applications

Reversed Phase

Sulfur Antibiotics on Kinetex 2.6u Biphenyl 50x3.0

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea

22146