6-MAM from urine by Strata-XC on a ZB-Drug1

6-MAM from urine by Strata-XC on a ZB-Drug1
GC Conditions
Column

Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea

Part No

7CD-G023-08

Phase Name

ZB-Drug-1

Injection

Split 10:1 @ 260°C

Carrier Gas

Constant Flow Helium, 0.3 mL/min

Detection

Mass Selective (MSD) @ (320°C)

Detection Info
Sample Notes

Analytes are 10ng/mL in urine derivatized with BSTFA Sim ions: (Quant ion*) D3-6-MAM (*402,403): 6-MAM (*399,400,340) Note: Method kept this way for continuity, the sample can be cleaned furthur by using different wash steps. For more information contact a Phenomenex technical consultant.

Sample Preparation Details
Condition 1

1 mL Methanol at 1 mL/min

Condition 2

1 mL Water at 1 mL/min

Condition 3

1 at 1

Load

Load 1.00 mL Sample diluted in Urine

Wash 1

1 mL 0.1 N HCl at 1 mL/min

Wash 2

1 mL Methanol at 1 mL/min

Wash 3

3 at 1

Dry

10minutes at > 10 inch Hg

Elution 1

1 mL Ammonium hydroxide in methanol 5% at 1 mL/min

Evaporation

Evaporate to dryness

Reconstitute

50 µL BSTFA/Pyridine

Order Items Used in This Application

Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea
7CD-G023-08

Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea

View Product

  • 1. 6-MAM-d3
  • 2. 6-MAM
Similar Applications