SecurityGuard Comparisons on Synergi 4u Max-RP 250 x 4.6mm With Cartridge

SecurityGuard Comparisons on Synergi 4u Max-RP 250 x 4.6mm With Cartridge
LC Conditions
Column

Synergi 4 µm Max-RP 80 Å, LC Column 250 x 4.6 mm, Ea

Brand

Synergi

Part No

00G-4337-E0

Phase Name

Max-RP

Elution Type

Isocratic

Mobile Phase

A: Acetonitrile

B: Water

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

65

35

Flow Rate

1.00 mL/min

Temperature

25°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

Analysis performed with SecurityGuard Cartridge PN: AJ0-6074 (cf. App IDs: 18816 and 18818) using Prodigy Test Mix (PN: AL0-3045)

Order Items Used in This Application

Synergi 4 µm Max-RP 80 Å, LC Column 250 x 4.6 mm, Ea
00G-4337-E0

Synergi 4 µm Max-RP 80 Å, LC Column 250 x 4.6 mm, Ea

View Product

  • 1. Uracil
  • 2. Acetophenone
  • 3. Toluene
  • 4. Naphthalene
-OEChem-06211003142D<br><br> 12 12  0     0  0  0  0  0  0999 V2000<br>    2.0000   -0.6900    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641   -0.6900    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -0.6900    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    0.8100    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -0.1900    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -0.1900    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    1.3100    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    0.8100    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -1.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3291    1.1200    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350    1.1200    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    1.9300    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  5  2  0  0  0  0<br>  2  6  2  0  0  0  0<br>  3  5  1  0  0  0  0<br>  3  6  1  0  0  0  0<br>  3  9  1  0  0  0  0<br>  4  5  1  0  0  0  0<br>  4  7  1  0  0  0  0<br>  4 10  1  0  0  0  0<br>  6  8  1  0  0  0  0<br>  7  8  2  0  0  0  0<br>  7 12  1  0  0  0  0<br>  8 11  1  0  0  0  0<br>M  END
Compound Name

Uracil

CID

1174

Molecular Formula

C4H4N2O2

Molecular Weight

112

No. Hydrogen Bond Acceptors

2

No. Hydrogen Bond Donors

2

Similar Applications

Hydrophilic Interaction

HILIC Separation of Nucleobases using a Diol HILIC column

Luna Omega 3µm HILIC 100Å, LC Column 150 x 4.6 mm, ea

28694

Reversed Phase

Extraction of 5-Fluorouracil from Human Serum Using Strata-X PRO SPE on a Kinetex 2.6 μm PS C18 (ESI -Ve Mode)

Kinetex 2.6 µm PS C18 100 Å, LC Column 150 x 3 mm, Ea

25778

Reversed Phase

Extraction of Uracil and Dihydrouracil from Human Serum Using Strata-X PRO SPE Using Kinetex 2.6 μm PS C18 (ESI +Ve mode)

Kinetex 2.6 µm PS C18 100 Å, LC Column 150 x 3 mm, Ea

25777

Reversed Phase

ABN7 on Luna Omega 1.6u PS C18 50x2.1mm

Luna Omega 1.6µm PS C18 100Å, LC Column 50 x 2.1 mm, EA

23707

Reversed Phase

Batch Reproducibility with ABN 7 mix- Kinetex 2.6u F5 50x4.6mm

Kinetex 2.6 µm F5 100 Å, LC Column 50 x 4.6 mm, Ea

22803

Reversed Phase

Batch reproducibility of Kinetex 5u EVO C18 150x4.6mm

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

22734

Reversed Phase

Pharma ABN Mixture using Kinetex 5u EVO C18 150x4.6mm

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

22718

Reversed Phase

Aeris Batch Reproducalbity #3: SRM 870 on Aeris PEPTIDE 1.7u XB-C18 50x4.6mm

Aeris 1.7 µm PEPTIDE XB-C18 100 Å, LC Column 50 x 2.1 mm, Ea

19909

Reversed Phase

Aeris WIDEPORE 3.6u XB-C18 150 x 2.1mm ID QC Chromatogram (AL0-8931)

Aeris 3.6 µm WIDEPORE XB-C18 200 Å, LC Column 150 x 2.1 mm, Ea

19812

Reversed Phase

Aeris 3.6u XB-C8 150 x 2.1mm ID QC Chromatogram (AL0-8931)

Aeris 3.6 µm WIDEPORE XB-C8 200 Å, LC Column 150 x 2.1 mm, Ea

19811

Reversed Phase

Aeris 3.6u C4 150 x 2.1mm ID QC Chromatogram (AL0-8931)

Aeris 3.6 µm WIDEPORE C4 200 Å, LC Column 150 x 2.1 mm, Ea

19810

Reversed Phase

SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm With KrudKatcher

Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea

18803

Reversed Phase

SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm With Cartridge

Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea

18802

Reversed Phase

SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm Without Cartridge

Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea

18801