Metanephrine and Normetanephrine on Kinetex 2.6 µm HILIC batch 48 pH 3.2 50 x 4.6 mm Agilent 1200
LC Conditions
Column
Kinetex 2.6 µm HILIC 100 Å, LC Column 50 x 4.6 mm, Ea
Brand
Kinetex
Part No
00B-4461-E0
Phase Name
HILIC
Elution Type
Isocratic
Mobile Phase
A: 90/10 ACN/100mM NH4 formate pH 3.2
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
2.00 mL/min
Temperature
0°C
Detection
UV-Vis Abs.-Diode Array (PDA) @ (25°C)
Detection Info
Order Items Used in This Application
- 1. Metanephrine
- 2. Normetanephrine
-OEChem-06211003162D<br><br> 29 29 0 1 0 0 0 0 0999 V2000<br> 3.7320 1.6550 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.8450 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -2.8450 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 2.6550 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 1.1550 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 4.5981 0.1550 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 1.6550 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.3450 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -0.3450 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.3450 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -1.3450 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.8450 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 3.1550 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -1.3450 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 2.0050 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6762 1.0724 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0747 1.7627 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1951 -0.0350 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 -0.0350 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9272 2.9650 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 -1.6550 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 2.2750 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.6401 2.6181 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8671 3.4650 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0201 3.6919 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 -3.1550 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3100 -0.8081 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -1.0350 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.6900 -1.8819 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 5 1 0 0 0 0<br> 1 22 1 0 0 0 0<br> 2 10 1 0 0 0 0<br> 2 14 1 0 0 0 0<br> 3 12 1 0 0 0 0<br> 3 26 1 0 0 0 0<br> 4 7 1 0 0 0 0<br> 4 13 1 0 0 0 0<br> 4 20 1 0 0 0 0<br> 5 6 1 0 0 0 0<br> 5 7 1 0 0 0 0<br> 5 15 1 0 0 0 0<br> 6 8 2 0 0 0 0<br> 6 9 1 0 0 0 0<br> 7 16 1 0 0 0 0<br> 7 17 1 0 0 0 0<br> 8 10 1 0 0 0 0<br> 8 18 1 0 0 0 0<br> 9 11 2 0 0 0 0<br> 9 19 1 0 0 0 0<br> 10 12 2 0 0 0 0<br> 11 12 1 0 0 0 0<br> 11 21 1 0 0 0 0<br> 13 23 1 0 0 0 0<br> 13 24 1 0 0 0 0<br> 13 25 1 0 0 0 0<br> 14 27 1 0 0 0 0<br> 14 28 1 0 0 0 0<br> 14 29 1 0 0 0 0<br>M END
Compound Name
Metanephrine
CID
21100
Molecular Formula
C10H15NO3
Molecular Weight
197
No. Hydrogen Bond Acceptors
4
No. Hydrogen Bond Donors
3
Similar Applications
Reversed Phase
uCATs by LCMS using Kinetex 2.6um Polar C18 50x4.6mm
Kinetex 2.6 µm Polar C18 100 Å, LC Column 50 x 4.6 mm, Ea
24172
Reversed Phase
uCATs by LCMS using Luna Omega 3um Polar C18 50x4.6mm
Luna Omega 3 µm Polar C18 100 Å, LC Column 50 x 4.6 mm, Ea
24171
Reversed Phase
pMETS in plasma using Luna Omega Polar C18 100x2.1mm
Luna Omega 1.6µm Polar C18 100Å, LC Column 100 x 2.1 mm, EA
23592
Reversed Phase
Catecholamines using Luna Omega Polar C18 100x2.1mm
Luna Omega 1.6µm Polar C18 100Å, LC Column 100 x 2.1 mm, EA
23591
Hydrophilic Interaction
Metanephrine and Normetanephrine on Kinetex 2.6 µm HILIC batch 48 pH 5.8 50 x 4.6 mm Agilent 1200
Kinetex 2.6 µm HILIC 100 Å, LC Column 50 x 4.6 mm, Ea
18881
Hydrophilic Interaction
Metanephrine and Normetanephrine on Kinetex 2.6 µm HILIC batch 48 pH 3.2 50 x 4.6 mm Agilent 1200
Kinetex 2.6 µm HILIC 100 Å, LC Column 50 x 4.6 mm, Ea
18880
Hydrophilic Interaction
Extraction of Metanephrine and Normetanephrine from Plasma On strata X-CW Using Luna HILIC
Luna 3 µm HILIC 200 Å, LC Column 50 x 2 mm, Ea
18462
Hydrophilic Interaction
Metanephrine and Normetanephrine on Luna HILIC 3um 50X2.0mm
Luna 3 µm HILIC 200 Å, LC Column 50 x 2 mm, Ea
18291
Hydrophilic Interaction
Plasma Metanephrines by LC/MS/MS on Luna HILIC following SPE with Strata-X-CW
Luna 3 µm HILIC 200 Å, LC Column 50 x 2 mm, Ea
17970
Reversed Phase
Catecholamines using Synergi Fusion-RP
Synergi 4 µm Fusion-RP 80 Å, LC Column 150 x 4.6 mm, Ea
15738
Reversed Phase
Catecholamines in 100% Aqueous by Gemini 5um C18
Gemini 5 µm C18 110 Å, LC Column 150 x 4.6 mm, Ea
15613
Reversed Phase
Polar Bases -- Catecholamines
Gemini 5 µm C18 110 Å, LC Column 150 x 4.6 mm, Ea
15025
Reversed Phase
Catecholamines on Synergi Hydro-RP
Synergi 4 µm Hydro-RP 80 Å, LC Column 150 x 4.6 mm, Ea
14217
Chiral
Normetanephrine
Chirex 3126 (D)-penicillamine, LC Column 150 x 4.6 mm, Ea
14160
Chiral
Normetanephrine
Chirex 3126 (D)-penicillamine, LC Column 150 x 4.6 mm, Ea
13861
Metanephrine
13651