Propafenone on Luna PFP-2 5 µm by SFC
LC Conditions
Column
Luna 5 µm PFP(2) 100 Å, LC Column 250 x 4.6 mm, Ea
Brand
Luna
Part No
00G-4448-E0
Phase Name
PFP(2)
Elution Type
Gradient
Mobile Phase
A: Methanol with 0.1% DEA
B: Carbon Dioxide
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
10
90
2
2
10
90
3
12
40
60
4
14
40
60
5
15
10
90
Flow Rate
3.00 mL/min
Temperature
35°C
Detection
UV-Vis Abs.-Fixed Wave. (UV) @ (35°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Silica 4 x 3.0mm, 10/Pk Part No.: AJ0-4348 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Propafenone
-OEChem-06211003152D<br><br> 52 53 0 1 0 0 0 0 0999 V2000<br> 8.0622 -1.2500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -0.2500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.9282 0.2500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.2500 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -1.2500 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 5.4641 -1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 -1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.6603 0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.6603 1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.7942 -1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.9282 -1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.7942 -0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 11.5263 1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.6603 -1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.9282 -2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.6603 -2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 11.5263 2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 12.3923 1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.7942 -3.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 12.3923 3.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 13.2583 1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 13.2583 2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8671 -0.9400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.0656 -2.2250 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.8626 -2.2250 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7976 -2.2250 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.5947 -2.2250 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -0.6300 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.3335 -2.2250 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.1306 -2.2250 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.8723 -0.3326 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 11.2708 0.3577 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.4482 1.8326 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.0497 1.1423 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.2646 -0.7751 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.4675 -0.7751 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 11.1972 -1.4400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.7932 0.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.3913 -3.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.6900 -1.2131 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -2.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3100 -2.2869 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.9893 3.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 12.3923 0.6300 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 11.1972 -3.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.7942 -3.8700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 12.3923 3.8700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 13.7953 1.4400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 13.7953 3.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 7 1 0 0 0 0<br> 1 13 1 0 0 0 0<br> 2 5 1 0 0 0 0<br> 2 41 1 0 0 0 0<br> 3 14 2 0 0 0 0<br> 4 6 1 0 0 0 0<br> 4 8 1 0 0 0 0<br> 4 31 1 0 0 0 0<br> 5 6 1 0 0 0 0<br> 5 7 1 0 0 0 0<br> 5 26 1 0 0 0 0<br> 6 27 1 0 0 0 0<br> 6 28 1 0 0 0 0<br> 7 29 1 0 0 0 0<br> 7 30 1 0 0 0 0<br> 8 11 1 0 0 0 0<br> 8 32 1 0 0 0 0<br> 8 33 1 0 0 0 0<br> 9 10 1 0 0 0 0<br> 9 14 1 0 0 0 0<br> 9 34 1 0 0 0 0<br> 9 35 1 0 0 0 0<br> 10 15 1 0 0 0 0<br> 10 36 1 0 0 0 0<br> 10 37 1 0 0 0 0<br> 11 18 1 0 0 0 0<br> 11 38 1 0 0 0 0<br> 11 39 1 0 0 0 0<br> 12 13 1 0 0 0 0<br> 12 14 1 0 0 0 0<br> 12 16 2 0 0 0 0<br> 13 17 2 0 0 0 0<br> 15 20 2 0 0 0 0<br> 15 21 1 0 0 0 0<br> 16 19 1 0 0 0 0<br> 16 40 1 0 0 0 0<br> 17 22 1 0 0 0 0<br> 17 42 1 0 0 0 0<br> 18 43 1 0 0 0 0<br> 18 44 1 0 0 0 0<br> 18 45 1 0 0 0 0<br> 19 22 2 0 0 0 0<br> 19 48 1 0 0 0 0<br> 20 23 1 0 0 0 0<br> 20 46 1 0 0 0 0<br> 21 24 2 0 0 0 0<br> 21 47 1 0 0 0 0<br> 22 49 1 0 0 0 0<br> 23 25 2 0 0 0 0<br> 23 50 1 0 0 0 0<br> 24 25 1 0 0 0 0<br> 24 51 1 0 0 0 0<br> 25 52 1 0 0 0 0<br>M END
Compound Name
Propafenone
CID
4932
Molecular Formula
C21H27NO3
Molecular Weight
341
No. Hydrogen Bond Acceptors
4
No. Hydrogen Bond Donors
2
Similar Applications
Chiral
Lux i-Amylose-3 Separation for Propafenone
Lux 5 µm i-Amylose-3, LC Column 250 x 4.6 mm, Ea
25345
Reversed Phase
Pharmaceutical drug mix using Kinetex 5u C18 100x4.6mm
Kinetex 5 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea
20885
Reversed Phase
KNX 5 Brochure - Pharma mix analysis using Kinetex 5um C18 150x4.6mm
Kinetex 5 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
20738
Impact of guard columns in SFC: Lux Amylose 2 with SecurityGuard
19112
Comparison of Cellulose 1, 2 and Amylose 2 Selectivity with IPA
19110
Comparison of Cellulose 1, 2 and Amylose 2 Selectivity with Methanol
19109
Impact of column length on Chiral Separations: 50mm length
19107
Impact of column length on Chiral Separations: 250mm length
19106
Propafenone on Lux 5 µm Amylose-2 by Chiral SFC
18975
Propafenone on Lux 5 µm Amylose-2 by Chiral SFC
18974
Propafenone on Lux 5 µm Amylose-2 by Chiral SFC
18973
Chiral
Propafenone on Lux 5 µm Cellulose-1 by Chiral SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
18972
Propafenone on Lux 5 µm Amylose-2 by Chiral SFC
18971