USP 621: Allowable changes Column Diameter-3.0mm ID

USP 621: Allowable changes Column Diameter-3.0mm ID
LC Conditions
Column

Luna 5 µm C18(2) 100 Å, LC Column 150 x 3 mm, Ea

Brand

Luna

Part No

00F-4252-Y0

Phase Name

C18(2)

Elution Type

Isocratic

Mobile Phase

A: See analyst note

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

100

0

Flow Rate

0.36 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

Isocratic: 100% of 2.0g of Sodium Octanesulphonate + 0.8g of Tetrabutyl Ammonium Hydrogen Sulphate in 2L of 360ml Methanol + 40ml of THF+1600ml of 3.4g of potassium Dihydrogen Phosphate in 2L of water (pH adjusted to 3.0 using Phosphoric acid)

Order Items Used in This Application

Luna 5 µm C18(2) 100 Å, LC Column 150 x 3 mm, Ea
00F-4252-Y0

Luna 5 µm C18(2) 100 Å, LC Column 150 x 3 mm, Ea

View Product

  • 1. Atenolol
  • 2. Impurity B
  • 3. Impurity F
  • 4. Impurity G
  • 5. Impurity I
  • 6. Impurity J
-OEChem-06211003142D<br><br> 41 41  0     1  0  0  0  0  0999 V2000<br>    5.4641   -0.6550    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641   -2.6550    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.1962    3.3450    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -3.6550    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3301    4.8450    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -2.6550    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -2.1550    0.0000 C   0  0  3  0  0  0  0  0  0  0  0  0<br>    2.8660   -4.1550    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -1.1550    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -5.1550    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -3.6550    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641    0.3450    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641    2.3450    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3301    0.8450    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    0.8450    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3301    1.8450    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    1.8450    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641    3.3450    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3301    3.8450    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.5200   -2.0724    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.1215   -2.7627    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -3.0050    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4030   -4.4650    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -3.9650    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.3860   -0.5724    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.9875   -1.2627    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.2460   -5.1550    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -5.7750    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4860   -5.1550    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3100   -3.1181    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -3.3450    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.6900   -4.1919    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641   -3.2750    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.8671    0.5350    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.0611    0.5350    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.8671    2.1550    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.0611    2.1550    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.2520    3.9276    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.8535    3.2373    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.8671    5.1550    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.7932    5.1550    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  9  1  0  0  0  0<br>  1 12  1  0  0  0  0<br>  2  7  1  0  0  0  0<br>  2 33  1  0  0  0  0<br>  3 19  2  0  0  0  0<br>  4  6  1  0  0  0  0<br>  4  8  1  0  0  0  0<br>  4 24  1  0  0  0  0<br>  5 19  1  0  0  0  0<br>  5 40  1  0  0  0  0<br>  5 41  1  0  0  0  0<br>  6  7  1  0  0  0  0<br>  6 20  1  0  0  0  0<br>  6 21  1  0  0  0  0<br>  7  9  1  0  0  0  0<br>  7 22  1  0  0  0  0<br>  8 10  1  0  0  0  0<br>  8 11  1  0  0  0  0<br>  8 23  1  0  0  0  0<br>  9 25  1  0  0  0  0<br>  9 26  1  0  0  0  0<br> 10 27  1  0  0  0  0<br> 10 28  1  0  0  0  0<br> 10 29  1  0  0  0  0<br> 11 30  1  0  0  0  0<br> 11 31  1  0  0  0  0<br> 11 32  1  0  0  0  0<br> 12 14  2  0  0  0  0<br> 12 15  1  0  0  0  0<br> 13 16  2  0  0  0  0<br> 13 17  1  0  0  0  0<br> 13 18  1  0  0  0  0<br> 14 16  1  0  0  0  0<br> 14 34  1  0  0  0  0<br> 15 17  2  0  0  0  0<br> 15 35  1  0  0  0  0<br> 16 36  1  0  0  0  0<br> 17 37  1  0  0  0  0<br> 18 19  1  0  0  0  0<br> 18 38  1  0  0  0  0<br> 18 39  1  0  0  0  0<br>M  END
Compound Name

Atenolol

CID

2249

Molecular Formula

C14H22N2O3

Molecular Weight

266

No. Hydrogen Bond Acceptors

4

No. Hydrogen Bond Donors

3

Similar Applications

Reversed Phase

Beta-blockers using Luna Omega Polar C18 50x2.1mm

Luna Omega 1.6µm Polar C18 100Å, LC Column 50 x 2.1 mm, EA

23611

Chiral

Atenolol on Lux 5µm Cellulose-1 by SFC

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

21034

Chiral

Atenolol on Lux 5µm Cellulose-1 by SFC

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

21033

Chiral

Atenolol on Lux 5µm Cellulose-1 in NP

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

20547

Chiral

Atenolol on Lux 5µm Cellulose-4 in NP

Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea

20536

Chiral

Atenolol on Lux 5µm Cellulose-2 in PO

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

20355

Chiral

Chiral HPLC Purification of Atenolol on Lux Cellulose-1

Lux 5 µm Cellulose-1, LC Column 250 x 21.2 mm, AXIA Packed, Ea

19269

Chiral

Chiral SFC Purification of Atenolol on Lux Cellulose-1

Lux 5 µm Cellulose-1, LC Column 250 x 21.2 mm, AXIA Packed, Ea

19266

Chiral

Atenolol on Lux 5 µm Cellulose-1 by Chiral SFC

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

19100

Chiral

Atenolol on Lux Cellulose-1

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

17382