Tetrahydroiso-alpha acids extracted from beer by Strata-X using Kinetex C18 2.6µm 100x4.6 mm
LC Conditions
Column
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea
Brand
Kinetex
Part No
00D-4462-E0
Phase Name
C18
Elution Type
Isocratic
Mobile Phase
A: Methanol
B: Water
C: Phosphoric acid
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
75
24
Flow Rate
1.40 mL/min
Temperature
0°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Preparation Details
Description
Strata-X 33 µm Polymeric Reversed Phase, 200 mg / 6 mL, Tubes, 30/Pk
Part No
8B-S100-FCH
Condition 1
4 mL Acidified methanol (0.05% H3PO4) at 1 mL/min
Condition 2
4 mL Water at 1 mL/min
Load
Load 5.00 mL Sample diluted in Miller Genuine Draft
Wash 1
4 mL 40% methanol in water at 1 mL/min
Dry
5 min @ >10 inches of Hg
Elution 1
2 mL Acidified methanol at 1 mL/min
Evaporation
Evaporate to dryness
Reconstitute
500 µL Mobile phase
Order Items Used in This Application
- 1. trans-Tetrahydroisocohumulone
- 2. cis-Tetrahydroisocohumulone
- 3. Tetrahydroisohumulone
- 4. Tetrahydroisoadhumulone
Similar Applications
No Similar applications found.