Ranitidine(Degraded) by HPLC - Luna 3µm C8(2) 100x4.6mm
LC Conditions
Column
Luna 3 µm C8(2) 100 Å, LC Column 100 x 4.6 mm, Ea
Brand
Luna
Part No
00D-4248-E0
Phase Name
C8(2)
Elution Type
Gradient
Mobile Phase
A: 98:2 40mM potassium phospahte pH 7.1:Acetonitrile
B: 78:22 40mM potassium phospahte pH 7.1:Acetonitrile
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
2
10
0
100
3
15
0
100
4
16
100
0
5
20
100
0
Flow Rate
1.50 mL/min
Temperature
35°C
Detection
UV-Vis Abs.-Diode Array (PDA) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, C8 4 x 3.0mm ID, 10/Pk Part No.: AJ0-4290 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Ranitidine amino alcohol hemifumarate
- 2. Ranitidine diamine hemifumarate
- 3. Ranitidine S-oxide
- 4. Ranitidine N-oxide
- 5. Ranitidine complex nitroacetamide
- 6. Ranitidine
Similar Applications