USP Acetaminophen, Acetylsalicylic Acid, Caffeine on Kinetex 2.6u C18 100x4.60mm on Shimadzu Nexera

USP Acetaminophen, Acetylsalicylic Acid, Caffeine on Kinetex 2.6u C18 100x4.60mm on Shimadzu Nexera
LC Conditions
Column

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea

Brand

Kinetex

Part No

00D-4462-E0

Phase Name

C18

Elution Type

Isocratic

Mobile Phase

A: 69:28:3 WaterAcetic Acid

Gradient Profile

Step No.

Time(min)

%A

%B

1

12

100

0

Flow Rate

2.00 mL/min

Temperature

0°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info

Order Items Used in This Application

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea
00D-4462-E0

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea

View Product

  • 1. Acetaminophen
  • 2. Caffeine
  • 3. Acetylsalicylic acid
  • 4. Benzoic acid
-OEChem-06211003142D<br><br> 20 20  0     0  0  0  0  0  0999 V2000<br>    2.8660   -2.5950    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    1.4050    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    1.4050    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    0.4050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -0.0950    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -0.0950    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -1.0950    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -1.0950    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -1.5950    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    1.9050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    2.9050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690    0.2150    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631    0.2150    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3291    1.7150    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -1.4050    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -1.4050    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.3520    2.9050    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    3.5250    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.1120    2.9050    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3291   -2.9050    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  9  1  0  0  0  0<br>  1 20  1  0  0  0  0<br>  2 10  2  0  0  0  0<br>  3  4  1  0  0  0  0<br>  3 10  1  0  0  0  0<br>  3 14  1  0  0  0  0<br>  4  5  2  0  0  0  0<br>  4  6  1  0  0  0  0<br>  5  7  1  0  0  0  0<br>  5 12  1  0  0  0  0<br>  6  8  2  0  0  0  0<br>  6 13  1  0  0  0  0<br>  7  9  2  0  0  0  0<br>  7 15  1  0  0  0  0<br>  8  9  1  0  0  0  0<br>  8 16  1  0  0  0  0<br> 10 11  1  0  0  0  0<br> 11 17  1  0  0  0  0<br> 11 18  1  0  0  0  0<br> 11 19  1  0  0  0  0<br>M  END
Compound Name

Acetaminophen

CID

1983

Molecular Formula

C8H9NO2

Molecular Weight

151

No. Hydrogen Bond Acceptors

2

No. Hydrogen Bond Donors

2

Similar Applications

Reversed Phase

Alternative Column for USP Monograph-227: 4-Aminophenol in Acetaminophen-Containing Drug Products_Sample solution on Kinetex EVO C18, 5 µm 150 x 4.6 mm 100 Å.

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

28424

Reversed Phase

Alternative Column for USP Monograph-227: 4-Aminophenol in Acetaminophen-Containing Drug Products_Standard solution on Kinetex EVO C18, 5 µm 150 x 4.6 mm 100 Å.

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

28422

Reversed Phase

Alternative Column for USP Monograph-227: 4-Aminophenol in Acetaminophen-Containing Drug Products_Sample solution on Luna Omega PS C18, 5 µm 150 x 4.6 mm 100 Å.

Luna Omega 5 µm PS C18 100Å, LC Column 150 x 4.6 mm, EA

28418

Reversed Phase

Alternative Column for USP Monograph-227: 4-Aminophenol in Acetaminophen-Containing Drug Products_Standard solution on Luna Omega PS C18, 5 µm 150 x 4.6 mm 100 Å.

Luna Omega 5 µm PS C18 100Å, LC Column 150 x 4.6 mm, EA

28416

Reversed Phase

Kinetex 2.6u C18 100A and LC Column 150 x 0.3 mm- Pharma Screen

Kinetex 2.6 µm C18 100 Å, LC Column 150 x 0.3 mm, Capillary, Ea

26400

Reversed Phase

Kinetex 2.6u C18 100A, LC Column 50 x 0.3 mm- Pharma Screen

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 0.3 mm, Capillary, Ea

26399

Reversed Phase

Kinetex 2.6u XB-C18 100A, LC Column 50 x 0.3 mm- Pharma Screen

Kinetex 2.6 µm XB-C18 100 Å, LC Column 50 x 0.3 mm, microflow, Ea

26324

Reversed Phase

Extraction of Acid, Basic, and Neutral Pharmaceuticals from Human Plasma Using Strata-X SPE on Kinetex 2.6 µm PS C18 LC Columns

Kinetex 2.6 µm PS C18 100 Å, LC Column 50 x 2.1 mm, Ea

25609

Reversed Phase

Resolution between Paracetamol and Paracetamol Impurity K (Ph.Eur.) on Kinetex 2.6 µm C18 100x2.1mm

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

25254

Reversed Phase

Cold medicine compounds on Kinetex 2.6 µm EVO C18

Kinetex 2.6 µm EVO C18 100 Å, LC Column 100 x 4.6 mm, EA

23036

Reversed Phase

Pharmaceutical drug mix using Kinetex 5u C18 100x4.6mm

Kinetex 5 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea

20885

Reversed Phase

KNX 5 Brochure - Pharma mix analysis using Kinetex 5um C18 150x4.6mm

Kinetex 5 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea

20738

Reversed Phase

Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 1.7u C18 100x2.1mm @ 0.60mL/min

Kinetex 1.7 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

20054

Reversed Phase

Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 2.6u C18 100x2.1mm @ 0.60mL/min

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

20053

Reversed Phase

Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 2.6 C18 100x2.1mm @ 1.0mL/min

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

20050

Reversed Phase

Pharma ABN Test 15 Mix on Un-Optimized Agilent 1100 system using Kinetex 2.6u C18 100x4.6mm

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea

20049

Reversed Phase

Pharma ABN Test 15 Mix on Optimized Agilent 1100 system using Kinetex 2.6u C18 100x4.6mm

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea

20048

Reversed Phase

Pharma ABN Test 15 Mix on Kinetex 2.6u C18 50x2.10mm @ 1.45mL/min 5min gradient

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

20041

Reversed Phase

Pharma ABN Test 15 Mix on Kinetex 1.7u C18 50x2.10mm @ 1.0mL/min 5min gradient

Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

20040

Reversed Phase

Pharma ABN Test 15 Mix on Kinetex 2.6u C18 50x2.10mm @ 0.8mL/min 5 ming gradient

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

20039

Reversed Phase

USP Acetaminophen Acetylsalicylic Acid Caffeine on Kinetex 1.7u C18 100x2.10mm on Shimadzu Nexera

Kinetex 1.7 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

19959

Reversed Phase

USP Acetaminophen, Acetylsalicylic Acid, Caffeine on Kinetex 2.6u C18 100x2.10mm on Shimadzu Nexera

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

19958

Reversed Phase

USP Acetaminophen, Acetylsalicylic Acid, Caffeine on Kinetex 2.6u C18 75x4.60mm on Shimadzu Nexera

Kinetex 2.6 µm C18 100 Å, LC Column 75 x 4.6 mm, Ea

19957

Reversed Phase

USP Acetaminophen, Acetylsalicylic Acid, Caffeine on Kinetex 2.6u C18 100x4.60mm on Shimadzu Nexera

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea

19956

Reversed Phase

Pharmaceutical Drug Mix on Kinetex 2.6 µm C18 50 x 2.1mm @ 0.8 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19944

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotien Data)

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19941

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 100 x 2.1mm @ 0.85 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

19940

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 75 x 2.1mm @ 1.1 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 75 x 2.1 mm, Ea

19939

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19914

Reversed Phase

Pharmaceutical Drug Mix on Kinetex 2.6 µm C18 50 x 2.1mm @ 0.8 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19911

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19862

Reversed Phase

Pharma ABN Test 11 Mix on Kinetex 2.6u C18 150x2.10mm using Acquity UPLC system

Kinetex 2.6 µm C18 100 Å, LC Column 150 x 2.1 mm, Ea

19789

Reversed Phase

Pharma ABN Test 11 Mix on Kinetex 1.7u C18 150x2.10mm using Acquity UPLC system

Kinetex 1.7 µm XB-C18 100 Å, LC Column 150 x 2.1 mm, Ea

19788

Reversed Phase

Pharma ABN Test 12 Mix on Kinetex 1.7u C18 50x2.10mm using Acquity UPLC system

Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19785

Reversed Phase

Pharma ABN Test 12 Mix on Kinetex 2.6u C18 50x2.10mm using Acquity UPLC system

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19784

Reversed Phase

Pharmaceutical Mixture on Kinetex 2.6µm C8 50x2.1mm ID

Kinetex 2.6 µm C8 100 Å, LC Column 50 x 2.1 mm, Ea

19476

Reversed Phase

Pharmaceutical Mixture on Kinetex XB-C18

Kinetex 2.6 µm XB-C18 100 Å, LC Column 50 x 2.1 mm, Ea

19475

Reversed Phase

Pharmaceutical Mixture on Kinetex C18

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19474

Reversed Phase

Analgesics and Anti-Inflammatories

Prodigy 5 µm Phenyl-3 (PH-3) 100 Å, LC Column 150 x 4.6 mm, Ea

10254