USP Acetaminophen, Acetylsalicylic Acid, Caffeine on Kinetex 2.6u C18 100x2.10mm on Shimadzu Nexera

USP Acetaminophen, Acetylsalicylic Acid, Caffeine on Kinetex 2.6u C18 100x2.10mm on Shimadzu Nexera
LC Conditions
Column

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

Brand

Kinetex

Part No

00D-4462-AN

Phase Name

C18

Elution Type

Isocratic

Mobile Phase

A: 69:28:3 WaterAcetic Acid

Gradient Profile

Step No.

Time(min)

%A

%B

1

12

100

0

Flow Rate

0.40 mL/min

Temperature

0°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info

Order Items Used in This Application

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
00D-4462-AN

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

View Product

  • 1. Acetaminophen
  • 2. Caffeine
  • 3. Acetylsalicylic acid
  • 4. Benzoic acid
-OEChem-06211003142D<br><br> 20 20  0     0  0  0  0  0  0999 V2000<br>    2.8660   -2.5950    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    1.4050    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    1.4050    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    0.4050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -0.0950    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -0.0950    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -1.0950    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -1.0950    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -1.5950    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    1.9050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    2.9050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690    0.2150    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631    0.2150    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3291    1.7150    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -1.4050    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -1.4050    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.3520    2.9050    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    3.5250    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.1120    2.9050    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3291   -2.9050    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  9  1  0  0  0  0<br>  1 20  1  0  0  0  0<br>  2 10  2  0  0  0  0<br>  3  4  1  0  0  0  0<br>  3 10  1  0  0  0  0<br>  3 14  1  0  0  0  0<br>  4  5  2  0  0  0  0<br>  4  6  1  0  0  0  0<br>  5  7  1  0  0  0  0<br>  5 12  1  0  0  0  0<br>  6  8  2  0  0  0  0<br>  6 13  1  0  0  0  0<br>  7  9  2  0  0  0  0<br>  7 15  1  0  0  0  0<br>  8  9  1  0  0  0  0<br>  8 16  1  0  0  0  0<br> 10 11  1  0  0  0  0<br> 11 17  1  0  0  0  0<br> 11 18  1  0  0  0  0<br> 11 19  1  0  0  0  0<br>M  END
Compound Name

Acetaminophen

CID

1983

Molecular Formula

C8H9NO2

Molecular Weight

151

No. Hydrogen Bond Acceptors

2

No. Hydrogen Bond Donors

2

Similar Applications

Reversed Phase

Cold medicine compounds on Kinetex 2.6 µm EVO C18

Kinetex 2.6 µm EVO C18 100 Å, LC Column 100 x 4.6 mm, EA

23036

Reversed Phase

Pharmaceutical drug mix using Kinetex 5u C18 100x4.6mm

Kinetex 5 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea

20885

Reversed Phase

KNX 5 Brochure - Pharma mix analysis using Kinetex 5um C18 150x4.6mm

Kinetex 5 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea

20738

Reversed Phase

Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 1.7u C18 100x2.1mm @ 0.60mL/min

Kinetex 1.7 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

20054

Reversed Phase

Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 2.6u C18 100x2.1mm @ 0.60mL/min

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

20053

Reversed Phase

Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 2.6 C18 100x2.1mm @ 1.0mL/min

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

20050

Reversed Phase

Pharma ABN Test 15 Mix on Un-Optimized Agilent 1100 system using Kinetex 2.6u C18 100x4.6mm

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea

20049

Reversed Phase

Pharma ABN Test 15 Mix on Optimized Agilent 1100 system using Kinetex 2.6u C18 100x4.6mm

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea

20048

Reversed Phase

USP Acetaminophen Acetylsalicylic Acid Caffeine on Kinetex 1.7u C18 100x2.10mm on Shimadzu Nexera

Kinetex 1.7 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

19959

Reversed Phase

USP Acetaminophen, Acetylsalicylic Acid, Caffeine on Kinetex 2.6u C18 100x2.10mm on Shimadzu Nexera

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

19958

Reversed Phase

USP Acetaminophen, Acetylsalicylic Acid, Caffeine on Kinetex 2.6u C18 75x4.60mm on Shimadzu Nexera

Kinetex 2.6 µm C18 100 Å, LC Column 75 x 4.6 mm, Ea

19957

Reversed Phase

USP Acetaminophen, Acetylsalicylic Acid, Caffeine on Kinetex 2.6u C18 100x4.60mm on Shimadzu Nexera

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea

19956

Reversed Phase

Pharmaceutical Drug Mix on Kinetex 2.6 µm C18 50 x 2.1mm @ 0.8 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19944

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotien Data)

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19941

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 100 x 2.1mm @ 0.85 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

19940

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 75 x 2.1mm @ 1.1 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 75 x 2.1 mm, Ea

19939

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19914

Reversed Phase

Pharmaceutical Drug Mix on Kinetex 2.6 µm C18 50 x 2.1mm @ 0.8 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19911

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19862

Reversed Phase

Pharmaceutical Mixture on Kinetex 2.6µm C8 50x2.1mm ID

Kinetex 2.6 µm C8 100 Å, LC Column 50 x 2.1 mm, Ea

19476

Reversed Phase

Pharmaceutical Mixture on Kinetex XB-C18

Kinetex 2.6 µm XB-C18 100 Å, LC Column 50 x 2.1 mm, Ea

19475

Reversed Phase

Pharmaceutical Mixture on Kinetex C18

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19474

Reversed Phase

Analgesics and Anti-Inflammatories

Prodigy 5 µm Phenyl-3 (PH-3) 100 Å, LC Column 150 x 4.6 mm, Ea

10254