Althiazide on Lux 5µm Cellulose-1 in RP
LC Conditions
Column
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4459-E0
Phase Name
Cellulose-1
Elution Type
Isocratic
Mobile Phase
A: ACN / 20mM NH4HCO3 (40:60) DEA (0.1%)
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-1, 4 x 3.0mm ID, 10/Pk Part No.: AJ0-8403 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Althiazide
- 2. Althiazide
-OEChem-06211003142D<br><br> 36 37 0 1 0 0 0 0 0999 V2000<br> 8.9942 0.0979 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -1.9263 0.0000 S 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.9942 -1.9504 0.0000 S 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.0737 0.0000 S 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9641 -2.7923 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.9641 -2.7923 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.4909 -2.8145 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.4976 -1.0863 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.4263 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 0.0737 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.8583 -2.4537 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -0.4263 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 6.3301 -1.4263 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -0.4263 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 0.0737 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.2241 -1.9609 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.2241 0.1084 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.1301 -1.4471 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.1301 -0.4054 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 1.5737 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 2.5737 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 3.0737 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 0.1937 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0611 -1.7363 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 0.6937 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1215 0.1814 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.5200 -0.5089 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.2169 -2.5809 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.2169 0.7284 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.2554 1.6814 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.6540 0.9911 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.3964 -2.1458 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.8559 -3.0737 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 2.8837 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 3.6937 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 2.7637 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 19 1 0 0 0 0<br> 2 5 2 0 0 0 0<br> 2 6 2 0 0 0 0<br> 2 9 1 0 0 0 0<br> 2 13 1 0 0 0 0<br> 3 7 2 0 0 0 0<br> 3 8 2 0 0 0 0<br> 3 11 1 0 0 0 0<br> 3 18 1 0 0 0 0<br> 4 15 1 0 0 0 0<br> 4 20 1 0 0 0 0<br> 9 12 1 0 0 0 0<br> 9 24 1 0 0 0 0<br> 10 12 1 0 0 0 0<br> 10 14 1 0 0 0 0<br> 10 25 1 0 0 0 0<br> 11 32 1 0 0 0 0<br> 11 33 1 0 0 0 0<br> 12 15 1 0 0 0 0<br> 12 23 1 0 0 0 0<br> 13 14 1 0 0 0 0<br> 13 16 2 0 0 0 0<br> 14 17 2 0 0 0 0<br> 15 26 1 0 0 0 0<br> 15 27 1 0 0 0 0<br> 16 18 1 0 0 0 0<br> 16 28 1 0 0 0 0<br> 17 19 1 0 0 0 0<br> 17 29 1 0 0 0 0<br> 18 19 2 0 0 0 0<br> 20 21 1 0 0 0 0<br> 20 30 1 0 0 0 0<br> 20 31 1 0 0 0 0<br> 21 22 2 0 0 0 0<br> 21 34 1 0 0 0 0<br> 22 35 1 0 0 0 0<br> 22 36 1 0 0 0 0<br>M END
Compound Name
Althiazide
CID
2122
Molecular Formula
C11H14ClN3O4S3
Molecular Weight
383
No. Hydrogen Bond Acceptors
7
No. Hydrogen Bond Donors
3