Flumequine on Lux 5µm Cellulose-2 in RP
LC Conditions
Column
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4457-E0
Phase Name
Cellulose-2
Elution Type
Isocratic
Mobile Phase
A: ACN / 20mM NH4HCO3 (60:40) with DEA (0.1%) in buffer
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-2, 4 x 3.0mm ID, 10/Pk Part No.: AJ0-8366 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Flumequine
- 2. Flumequine
-OEChem-06211003152D<br><br> 31 33 0 1 0 0 0 0 0999 V2000<br> 2.0000 -2.8205 0.0000 F 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.9200 0.7246 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5180 2.2246 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7860 2.2246 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5180 -0.7754 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3775 -1.2701 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 6.3909 -2.2618 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5452 -2.7796 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.6520 -1.2754 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.6681 -2.3169 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7860 -0.7754 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.2398 -0.7637 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5180 0.2246 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7700 -2.8446 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.6520 0.7246 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7860 0.2246 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8760 -1.2822 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8680 -2.3238 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.6520 1.7246 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3748 -0.6501 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.6156 -2.8396 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.9995 -2.1433 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1630 -3.2679 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.9577 -3.2424 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.5538 -1.2984 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7744 -0.4498 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.9258 -0.2291 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0550 0.5346 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7724 -3.4646 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3427 -0.9660 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5180 2.8446 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 18 1 0 0 0 0<br> 2 16 2 0 0 0 0<br> 3 19 1 0 0 0 0<br> 3 31 1 0 0 0 0<br> 4 19 2 0 0 0 0<br> 5 6 1 0 0 0 0<br> 5 9 1 0 0 0 0<br> 5 13 1 0 0 0 0<br> 6 7 1 0 0 0 0<br> 6 12 1 0 0 0 0<br> 6 20 1 0 0 0 0<br> 7 8 1 0 0 0 0<br> 7 21 1 0 0 0 0<br> 7 22 1 0 0 0 0<br> 8 10 1 0 0 0 0<br> 8 23 1 0 0 0 0<br> 8 24 1 0 0 0 0<br> 9 10 2 0 0 0 0<br> 9 11 1 0 0 0 0<br> 10 14 1 0 0 0 0<br> 11 16 1 0 0 0 0<br> 11 17 2 0 0 0 0<br> 12 25 1 0 0 0 0<br> 12 26 1 0 0 0 0<br> 12 27 1 0 0 0 0<br> 13 15 2 0 0 0 0<br> 13 28 1 0 0 0 0<br> 14 18 2 0 0 0 0<br> 14 29 1 0 0 0 0<br> 15 16 1 0 0 0 0<br> 15 19 1 0 0 0 0<br> 17 18 1 0 0 0 0<br> 17 30 1 0 0 0 0<br>M END
Compound Name
Flumequine
CID
3374
Molecular Formula
C14H12FNO3
Molecular Weight
261
No. Hydrogen Bond Acceptors
5
No. Hydrogen Bond Donors
1
Similar Applications
Reversed Phase
Antibiotics by LCMS using Kinetex 2.6u Biphenyl 50x2.1mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea
22161
Chiral
Flumequine on Lux 5µm Cellulose-2 in RP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20141