Methoxamine on Lux 5µm Cellulose-4 in NP
LC Conditions
Column
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4491-E0
Phase Name
Cellulose-4
Elution Type
Isocratic
Mobile Phase
A: Hexane / IPA (60:40) DEA (0.1%)
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-4 4 x 3.0 mm, 10/Pk Part No.: AJ0-8627 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Methoxamine
- 2. Methoxamine
-OEChem-06211003152D<br><br> 32 32 0 1 0 0 0 0 0999 V2000<br> 3.7320 1.5950 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 0.0950 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -1.9050 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 2.5950 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 1.0950 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 5.4641 1.5950 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 4.5981 0.0950 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 1.0950 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.4050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -0.4050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -1.4050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.4050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.9050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.4050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -2.9050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 1.9450 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.2002 2.0200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0201 0.5581 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8671 0.7850 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.6401 1.6319 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 -0.0950 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 2.9050 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9272 2.9050 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1951 -1.7150 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 2.2150 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -2.5250 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.6900 0.1319 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -0.7150 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3100 -0.9419 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.7101 -2.9050 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -3.5250 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.9501 -2.9050 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 5 1 0 0 0 0<br> 1 25 1 0 0 0 0<br> 2 9 1 0 0 0 0<br> 2 14 1 0 0 0 0<br> 3 11 1 0 0 0 0<br> 3 15 1 0 0 0 0<br> 4 6 1 0 0 0 0<br> 4 22 1 0 0 0 0<br> 4 23 1 0 0 0 0<br> 5 6 1 0 0 0 0<br> 5 7 1 0 0 0 0<br> 5 16 1 0 0 0 0<br> 6 8 1 0 0 0 0<br> 6 17 1 0 0 0 0<br> 7 9 2 0 0 0 0<br> 7 10 1 0 0 0 0<br> 8 18 1 0 0 0 0<br> 8 19 1 0 0 0 0<br> 8 20 1 0 0 0 0<br> 9 12 1 0 0 0 0<br> 10 11 2 0 0 0 0<br> 10 21 1 0 0 0 0<br> 11 13 1 0 0 0 0<br> 12 13 2 0 0 0 0<br> 12 24 1 0 0 0 0<br> 13 26 1 0 0 0 0<br> 14 27 1 0 0 0 0<br> 14 28 1 0 0 0 0<br> 14 29 1 0 0 0 0<br> 15 30 1 0 0 0 0<br> 15 31 1 0 0 0 0<br> 15 32 1 0 0 0 0<br>M END
Compound Name
Methoxamine
CID
6082
Molecular Formula
C11H17NO3
Molecular Weight
211
No. Hydrogen Bond Acceptors
4
No. Hydrogen Bond Donors
2
Similar Applications
Chiral
Methoxamine on Lux 5µm Cellulose-4 in NP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
20155