Reboxetine on Lux 5µm Cellulose-2 in RP
LC Conditions
Column
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4457-E0
Phase Name
Cellulose-2
Elution Type
Isocratic
Mobile Phase
A: ACN / 20mM NH4HCO3+0.1%DEA (60:40) with None in buffer
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-2, 4 x 3.0mm ID, 10/Pk Part No.: AJ0-8366 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Reboxetine
- 2. Reboxetine
-OEChem-05151001062D<br><br> 46 48 0 1 0 0 0 0 0999 V2000<br> 6.3301 -1.7500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 0.2500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 1.2500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -2.7500 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -1.2500 0.0000 C 0 0 2 0 0 0 0 0 0 0 0 0<br> 5.4641 -0.2500 0.0000 C 0 0 2 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -3.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 -0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0622 0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0622 1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 3.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.2002 -0.8250 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 0.3700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3860 -1.1674 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.9875 -1.8577 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.0656 -3.7250 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.8626 -3.7250 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5422 -3.3326 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.9407 -2.6423 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0611 -3.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.7932 1.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 -0.8700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 2.3700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.5991 -0.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.5991 1.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 1.4400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1951 3.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 3.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 3.8700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.3894 1.8577 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.7880 1.1674 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.6200 2.7500 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 3.3700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.3800 2.7500 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 5 1 0 0 0 0<br> 1 9 1 0 0 0 0<br> 6 2 1 1 0 0 0<br> 2 13 1 0 0 0 0<br> 3 16 1 0 0 0 0<br> 3 22 1 0 0 0 0<br> 4 7 1 0 0 0 0<br> 4 8 1 0 0 0 0<br> 4 32 1 0 0 0 0<br> 5 6 1 0 0 0 0<br> 5 7 1 0 0 0 0<br> 5 24 1 6 0 0 0<br> 6 10 1 0 0 0 0<br> 6 25 1 0 0 0 0<br> 7 26 1 0 0 0 0<br> 7 27 1 0 0 0 0<br> 8 9 1 0 0 0 0<br> 8 28 1 0 0 0 0<br> 8 29 1 0 0 0 0<br> 9 30 1 0 0 0 0<br> 9 31 1 0 0 0 0<br> 10 11 2 0 0 0 0<br> 10 12 1 0 0 0 0<br> 11 14 1 0 0 0 0<br> 11 33 1 0 0 0 0<br> 12 15 2 0 0 0 0<br> 12 34 1 0 0 0 0<br> 13 16 1 0 0 0 0<br> 13 18 2 0 0 0 0<br> 14 17 2 0 0 0 0<br> 14 35 1 0 0 0 0<br> 15 17 1 0 0 0 0<br> 15 36 1 0 0 0 0<br> 16 19 2 0 0 0 0<br> 17 37 1 0 0 0 0<br> 18 20 1 0 0 0 0<br> 18 38 1 0 0 0 0<br> 19 21 1 0 0 0 0<br> 19 39 1 0 0 0 0<br> 20 21 2 0 0 0 0<br> 20 40 1 0 0 0 0<br> 21 41 1 0 0 0 0<br> 22 23 1 0 0 0 0<br> 22 42 1 0 0 0 0<br> 22 43 1 0 0 0 0<br> 23 44 1 0 0 0 0<br> 23 45 1 0 0 0 0<br> 23 46 1 0 0 0 0<br>M END
Compound Name
Reboxetine
CID
65856
Molecular Formula
C19H23NO3
Molecular Weight
313
No. Hydrogen Bond Acceptors
4
No. Hydrogen Bond Donors
1
Similar Applications
Chiral
Reboxetine on Lux 5µm Cellulose-3 in NP
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
20394
Chiral
Reboxetine on Lux 5µm Cellulose-4 in NP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
20351
Chiral
Reboxetine on Lux 5µm Cellulose-2 in RP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20235
Chiral
Reboxetine on Lux 5µm Cellulose-1 in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
20056
Chiral
Reboxetine mesylate on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17450
Chiral
Reboxetine mesylate on Lux Cellulose-2
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17354
Chiral
Reboxetine mesylate on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17353