Amlodipine on Lux 5µm Cellulose-4 in PO
LC Conditions
Column
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4491-E0
Phase Name
Cellulose-4
Elution Type
Isocratic
Mobile Phase
A: ACN / IPA (95:5) DEA (0.1%)
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-4 4 x 3.0 mm, 10/Pk Part No.: AJ0-8627 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Amlodipine
- 2. Amlodipine
-OEChem-06211003142D<br><br> 53 54 0 1 0 0 0 0 0999 V2000<br> 8.1810 2.9836 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.6900 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 0.8100 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.9282 0.8100 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 2.3100 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.7050 2.0760 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -0.6900 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -3.6900 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 1.3100 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 5.4641 0.8100 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 0.8100 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -0.1900 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 -0.1900 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 2.3100 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -0.6900 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 1.3100 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0622 -0.6900 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0622 1.3100 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 2.8100 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 2.8100 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 3.8100 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 3.8100 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 4.3100 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.1900 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 1.3100 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -3.1900 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.7942 1.3100 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 0.8100 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8671 1.6200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -1.3100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3860 -0.1074 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.9875 -0.7977 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7522 -1.2269 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.5991 -1.0000 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.3722 -0.1531 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9272 2.5000 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7331 4.1200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9272 4.1200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 4.9300 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.5200 -1.6074 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1215 -2.2977 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.2646 1.7850 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.4675 1.7850 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.9441 -3.7726 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3426 -3.0823 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.1042 0.7731 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.3312 1.6200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.4842 1.8469 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.6900 1.3469 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 0.5000 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3100 0.2731 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -4.3100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 -3.3800 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 19 1 0 0 0 0<br> 2 15 1 0 0 0 0<br> 2 24 1 0 0 0 0<br> 3 16 1 0 0 0 0<br> 3 25 1 0 0 0 0<br> 4 18 1 0 0 0 0<br> 4 27 1 0 0 0 0<br> 5 16 2 0 0 0 0<br> 6 18 2 0 0 0 0<br> 7 12 1 0 0 0 0<br> 7 13 1 0 0 0 0<br> 7 30 1 0 0 0 0<br> 8 26 1 0 0 0 0<br> 8 52 1 0 0 0 0<br> 8 53 1 0 0 0 0<br> 9 10 1 0 0 0 0<br> 9 11 1 0 0 0 0<br> 9 14 1 0 0 0 0<br> 9 29 1 0 0 0 0<br> 10 12 2 0 0 0 0<br> 10 16 1 0 0 0 0<br> 11 13 2 0 0 0 0<br> 11 18 1 0 0 0 0<br> 12 15 1 0 0 0 0<br> 13 17 1 0 0 0 0<br> 14 19 1 0 0 0 0<br> 14 20 2 0 0 0 0<br> 15 31 1 0 0 0 0<br> 15 32 1 0 0 0 0<br> 17 33 1 0 0 0 0<br> 17 34 1 0 0 0 0<br> 17 35 1 0 0 0 0<br> 19 21 2 0 0 0 0<br> 20 22 1 0 0 0 0<br> 20 36 1 0 0 0 0<br> 21 23 1 0 0 0 0<br> 21 37 1 0 0 0 0<br> 22 23 2 0 0 0 0<br> 22 38 1 0 0 0 0<br> 23 39 1 0 0 0 0<br> 24 26 1 0 0 0 0<br> 24 40 1 0 0 0 0<br> 24 41 1 0 0 0 0<br> 25 28 1 0 0 0 0<br> 25 42 1 0 0 0 0<br> 25 43 1 0 0 0 0<br> 26 44 1 0 0 0 0<br> 26 45 1 0 0 0 0<br> 27 46 1 0 0 0 0<br> 27 47 1 0 0 0 0<br> 27 48 1 0 0 0 0<br> 28 49 1 0 0 0 0<br> 28 50 1 0 0 0 0<br> 28 51 1 0 0 0 0<br>M END
Compound Name
Amlodipine
CID
2162
Molecular Formula
C20H25ClN2O5
Molecular Weight
408
No. Hydrogen Bond Acceptors
7
No. Hydrogen Bond Donors
2
Similar Applications
Reversed Phase
USP Amlodipine and Olmesartan Medoxomil Tablets - Impurity standard solution - Kinetex Phenyl-Hexyl
Kinetex 5 µm Phenyl-Hexyl 100 Å, LC Column 250 x 4.6 mm, Ea
28292
Reversed Phase
USP Amlodipine and Olmesartan Medoxomil Tablets - Standard solution - Kinetex Phenyl-Hexyl
Kinetex 5 µm Phenyl-Hexyl 100 Å, LC Column 250 x 4.6 mm, Ea
28291
Reversed Phase
USP Amlodipine and Olmesartan Medoxomil Tablets - Impurity standard solution - Kinetex Biphenyl
Kinetex 5 µm Biphenyl 100 Å, LC Column 250 x 4.6 mm, Ea
28290
Reversed Phase
USP Amlodipine and Olmesartan Medoxomil Tablets - Standard solution - Kinetex Biphenyl
Kinetex 5 µm Biphenyl 100 Å, LC Column 250 x 4.6 mm, Ea
28289
Reversed Phase
USP Amlodipine, Valsartan, and Hydrochlorothiazide Tablets –Assay and Impurities- Amlodipine,Valsartan,Hydrochlorothiazide Standard solution Chromatogram USP-Impurities
Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
28202
Reversed Phase
USP Amlodipine, Valsartan, and Hydrochlorothiazide Tablets –Assay and Impurities- Amlodipine,Valsartan,Hydrochlorothiazide Sensitivity solution Chromatogram USP-Impurities
Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
28201
Reversed Phase
USP Amlodipine, Valsartan, and Hydrochlorothiazide Tablets –Assay and Impurities- Amlodipine,Valsartan,Hydrochlorothiazide System suitability solution Chromatogram USP-Impurities
Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
28200
Reversed Phase
USP Amlodipine, Valsartan, and Hydrochlorothiazide Tablets –Assay and Impurities-Amlodipine,Valsartan,Hydrochlorothiazide Standard solution-SST Chromatogram USP-Assay
Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
28196
Chiral
LC-MS/MS Chromatograms for Amlodipine Plasma Blank and Plasma Spiked at LLOQ
Lux 3 µm Cellulose-4, LC Column 150 x 2 mm, Ea
25533
Chiral
Calibration Curves for (R)-Amlodipine and (S)-Amlodipine
Lux 3 µm Cellulose-4, LC Column 150 x 2 mm, Ea
25532
Chiral
LC-MS/MS Chromatogram for Amlodipine Enantiomers and Internal Standards
Lux 3 µm Cellulose-4, LC Column 150 x 2 mm, Ea
25531
Chiral
LC-MS/MS Chromatogram for Amlodipine Enantiomers on Lux Cellulose-4
Lux 3 µm Cellulose-4, LC Column 150 x 2 mm, Ea
25530
Chiral
Amlodipine on Lux 5µm Cellulose-4 in PO
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
20358