Carazolol on Lux 5µm Cellulose-1 in NP
LC Conditions
Column
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4459-E0
Phase Name
Cellulose-1
Elution Type
Isocratic
Mobile Phase
A: Hexane / EtOH (80:20) DEA (0.1%)
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-1, 4 x 3.0mm ID, 10/Pk Part No.: AJ0-8403 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Carazolol
- 2. Carazolol
-OEChem-05151001062D<br><br> 44 46 0 1 0 0 0 0 0999 V2000<br> 5.3923 0.6019 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7524 -1.2930 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5274 3.8729 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0733 -2.7946 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.0274 2.3340 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.7328 -1.0964 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 4.0274 2.3340 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.3364 3.2851 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3933 -1.8472 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7183 3.2851 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.7123 1.5493 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0528 -0.1490 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7338 -3.5455 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3518 3.5173 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7328 1.7580 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.3424 1.5493 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.7029 3.5173 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.0547 2.7487 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.4138 -4.4929 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7143 -3.3489 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3219 1.7580 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 2.7487 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5344 -1.6838 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.9374 -2.1446 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7807 -1.3631 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5968 -0.4463 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.4402 0.3352 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.1259 -3.6673 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5274 4.4929 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4654 -2.9165 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5365 4.1092 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1459 1.2957 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.5408 0.9619 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5182 4.1092 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.6607 2.8799 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.8264 -4.2945 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.2154 -5.0803 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.0012 -4.6913 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.8362 -3.9568 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.3222 -3.2270 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.5924 -2.7410 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.9088 1.2957 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.3940 2.8799 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5540 -1.8804 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 11 1 0 0 0 0<br> 1 12 1 0 0 0 0<br> 2 6 1 0 0 0 0<br> 2 44 1 0 0 0 0<br> 3 8 1 0 0 0 0<br> 3 10 1 0 0 0 0<br> 3 29 1 0 0 0 0<br> 4 9 1 0 0 0 0<br> 4 13 1 0 0 0 0<br> 4 30 1 0 0 0 0<br> 5 7 1 0 0 0 0<br> 5 8 2 0 0 0 0<br> 5 11 1 0 0 0 0<br> 6 9 1 0 0 0 0<br> 6 12 1 0 0 0 0<br> 6 23 1 0 0 0 0<br> 7 10 1 0 0 0 0<br> 7 16 2 0 0 0 0<br> 8 14 1 0 0 0 0<br> 9 24 1 0 0 0 0<br> 9 25 1 0 0 0 0<br> 10 17 2 0 0 0 0<br> 11 15 2 0 0 0 0<br> 12 26 1 0 0 0 0<br> 12 27 1 0 0 0 0<br> 13 19 1 0 0 0 0<br> 13 20 1 0 0 0 0<br> 13 28 1 0 0 0 0<br> 14 18 2 0 0 0 0<br> 14 31 1 0 0 0 0<br> 15 18 1 0 0 0 0<br> 15 32 1 0 0 0 0<br> 16 21 1 0 0 0 0<br> 16 33 1 0 0 0 0<br> 17 22 1 0 0 0 0<br> 17 34 1 0 0 0 0<br> 18 35 1 0 0 0 0<br> 19 36 1 0 0 0 0<br> 19 37 1 0 0 0 0<br> 19 38 1 0 0 0 0<br> 20 39 1 0 0 0 0<br> 20 40 1 0 0 0 0<br> 20 41 1 0 0 0 0<br> 21 22 2 0 0 0 0<br> 21 42 1 0 0 0 0<br> 22 43 1 0 0 0 0<br>M END
Compound Name
Carazolol
CID
71739
Molecular Formula
C18H22N2O2
Molecular Weight
298
No. Hydrogen Bond Acceptors
3
No. Hydrogen Bond Donors
3
Similar Applications
Chiral
Carazolol on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23311
Chiral
Carazolol on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21085
Chiral
Carazolol on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21084
Chiral
Carazolol on Lux 5µm Cellulose-2 by SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21083
Chiral
Carazolol on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21082
Chiral
Carazolol on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21081
Chiral
Carazolol on Lux 5µm Cellulose-1 in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
20434
Chiral
Carazolol on Lux 5µm Cellulose-4 in NP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
20153
Chiral
Carazolol on Lux 5µm Cellulose-2 in NP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20117
Chiral
Carazolol on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17370