Cyclothiazide on Lux 5µm Cellulose-1 in NP
LC Conditions
Column
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4459-E0
Phase Name
Cellulose-1
Elution Type
Isocratic
Mobile Phase
A: Hexane / EtOH (80:20) DEA (0.1%)
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-1, 4 x 3.0mm ID, 10/Pk Part No.: AJ0-8403 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Cyclothiazide
- 2. Cyclothiazide
-OEChem-06211003152D<br><br> 40 43 0 1 0 0 0 0 0999 V2000<br> 10.8189 0.9989 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.2888 -1.0253 0.0000 S 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.8189 -1.0494 0.0000 S 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7888 -1.8913 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7888 -1.8913 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.3155 -1.9135 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 11.3222 -0.1853 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.4227 -0.5253 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.2888 0.9747 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 11.6830 -1.5528 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5567 0.9747 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 3.6248 0.4571 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 2.7588 0.9571 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 5.2979 1.9406 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5849 2.1728 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.4227 0.4747 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.3749 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.8749 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.1548 0.4747 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.1548 -0.5253 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.0487 1.0094 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.0487 -1.0599 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.9548 -0.5461 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.9548 0.4955 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4758 0.3600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0336 -0.0091 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1921 0.5136 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.8906 2.1225 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.0948 2.5264 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.9534 2.6713 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.9837 2.3245 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.9597 0.1647 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.0653 -1.9620 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4129 -1.0742 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.8858 -0.8353 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.2888 1.5947 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.0416 1.6293 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.0416 -1.6799 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 12.2211 -1.2448 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 11.6806 -2.1728 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 24 1 0 0 0 0<br> 2 4 2 0 0 0 0<br> 2 5 2 0 0 0 0<br> 2 8 1 0 0 0 0<br> 2 20 1 0 0 0 0<br> 3 6 2 0 0 0 0<br> 3 7 2 0 0 0 0<br> 3 10 1 0 0 0 0<br> 3 23 1 0 0 0 0<br> 8 16 1 0 0 0 0<br> 8 35 1 0 0 0 0<br> 9 16 1 0 0 0 0<br> 9 19 1 0 0 0 0<br> 9 36 1 0 0 0 0<br> 10 39 1 0 0 0 0<br> 10 40 1 0 0 0 0<br> 11 12 1 0 0 0 0<br> 11 14 1 0 0 0 0<br> 11 16 1 0 0 0 0<br> 11 25 1 0 0 0 0<br> 12 15 1 0 0 0 0<br> 12 17 1 0 0 0 0<br> 12 26 1 0 0 0 0<br> 13 14 1 0 0 0 0<br> 13 15 1 0 0 0 0<br> 13 18 1 0 0 0 0<br> 13 27 1 0 0 0 0<br> 14 28 1 0 0 0 0<br> 14 29 1 0 0 0 0<br> 15 30 1 0 0 0 0<br> 15 31 1 0 0 0 0<br> 16 32 1 0 0 0 0<br> 17 18 2 0 0 0 0<br> 17 33 1 0 0 0 0<br> 18 34 1 0 0 0 0<br> 19 20 1 0 0 0 0<br> 19 21 2 0 0 0 0<br> 20 22 2 0 0 0 0<br> 21 24 1 0 0 0 0<br> 21 37 1 0 0 0 0<br> 22 23 1 0 0 0 0<br> 22 38 1 0 0 0 0<br> 23 24 2 0 0 0 0<br>M END
Compound Name
Cyclothiazide
CID
2910
Molecular Formula
C14H16ClN3O4S2
Molecular Weight
389
No. Hydrogen Bond Acceptors
7
No. Hydrogen Bond Donors
3
Similar Applications
Chiral
Cyclothiazide on Lux 5µm Cellulose-1 in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
20560