Prodigy Test Mix on Kinetex 1.7u C18 on Acquity System

Prodigy Test Mix on Kinetex 1.7u C18 on Acquity System
LC Conditions
Column

Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

Brand

Kinetex

Part No

00B-4475-AN

Phase Name

C18

Elution Type

Isocratic

Mobile Phase

A: Water

B: Acetonitrile

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

50

50

Flow Rate

0.50 mL/min

Temperature

30°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info

Order Items Used in This Application

Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
00B-4475-AN

Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

View Product

  • 1. Uracil
  • 2. Acetophenone
  • 3. Toluene
  • 4. Naphthalene
-OEChem-06211003142D<br><br> 12 12  0     0  0  0  0  0  0999 V2000<br>    2.0000   -0.6900    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641   -0.6900    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -0.6900    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    0.8100    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -0.1900    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -0.1900    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    1.3100    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    0.8100    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -1.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3291    1.1200    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350    1.1200    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    1.9300    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  5  2  0  0  0  0<br>  2  6  2  0  0  0  0<br>  3  5  1  0  0  0  0<br>  3  6  1  0  0  0  0<br>  3  9  1  0  0  0  0<br>  4  5  1  0  0  0  0<br>  4  7  1  0  0  0  0<br>  4 10  1  0  0  0  0<br>  6  8  1  0  0  0  0<br>  7  8  2  0  0  0  0<br>  7 12  1  0  0  0  0<br>  8 11  1  0  0  0  0<br>M  END
Compound Name

Uracil

CID

1174

Molecular Formula

C4H4N2O2

Molecular Weight

112

No. Hydrogen Bond Acceptors

2

No. Hydrogen Bond Donors

2

Similar Applications

Hydrophilic Interaction

HILIC Separation of Nucleobases using a Diol HILIC column

Luna Omega 3µm HILIC 100Å, LC Column 150 x 4.6 mm, ea

28694

Reversed Phase

Extraction of 5-Fluorouracil from Human Serum Using Strata-X PRO SPE on a Kinetex 2.6 μm PS C18 (ESI -Ve Mode)

Kinetex 2.6 µm PS C18 100 Å, LC Column 150 x 3 mm, Ea

25778

Reversed Phase

Extraction of Uracil and Dihydrouracil from Human Serum Using Strata-X PRO SPE Using Kinetex 2.6 μm PS C18 (ESI +Ve mode)

Kinetex 2.6 µm PS C18 100 Å, LC Column 150 x 3 mm, Ea

25777

Reversed Phase

ABN7 on Luna Omega 1.6u PS C18 50x2.1mm

Luna Omega 1.6µm PS C18 100Å, LC Column 50 x 2.1 mm, EA

23707

Reversed Phase

Batch Reproducibility with ABN 7 mix- Kinetex 2.6u F5 50x4.6mm

Kinetex 2.6 µm F5 100 Å, LC Column 50 x 4.6 mm, Ea

22803

Reversed Phase

Batch reproducibility of Kinetex 5u EVO C18 150x4.6mm

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

22734

Reversed Phase

Pharma ABN Mixture using Kinetex 5u EVO C18 150x4.6mm

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

22718

Reversed Phase

Aeris Batch Reproducalbity #3: SRM 870 on Aeris PEPTIDE 1.7u XB-C18 50x4.6mm

Aeris 1.7 µm PEPTIDE XB-C18 100 Å, LC Column 50 x 2.1 mm, Ea

19909

Reversed Phase

Aeris WIDEPORE 3.6u XB-C18 150 x 2.1mm ID QC Chromatogram (AL0-8931)

Aeris 3.6 µm WIDEPORE XB-C18 200 Å, LC Column 150 x 2.1 mm, Ea

19812

Reversed Phase

Aeris 3.6u XB-C8 150 x 2.1mm ID QC Chromatogram (AL0-8931)

Aeris 3.6 µm WIDEPORE XB-C8 200 Å, LC Column 150 x 2.1 mm, Ea

19811

Reversed Phase

Aeris 3.6u C4 150 x 2.1mm ID QC Chromatogram (AL0-8931)

Aeris 3.6 µm WIDEPORE C4 200 Å, LC Column 150 x 2.1 mm, Ea

19810

Reversed Phase

SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm With KrudKatcher

Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea

18803

Reversed Phase

SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm With Cartridge

Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea

18802

Reversed Phase

SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm Without Cartridge

Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea

18801