Preparative loading on Kinetex 5u C18 in Axia 50x21.2mm
LC Conditions
Column
Kinetex 5 µm C18 100 Å, LC Column 50 x 21.2 mm, AXIA Packed, Ea
Brand
Kinetex
Part No
00B-4601-P0-AX
Phase Name
C18
Elution Type
Gradient
Mobile Phase
A: Water with 0.5% Formic Acid
B: Acetonitrile with 0.5% Formic acid
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
80
20
2
8
50
50
3
11
50
50
Flow Rate
30.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Order Items Used in This Application
- 1. Doxepin
- 2. Amitriptyline
-OEChem-04281015372D<br><br> 42 44 0 0 0 0 0 0 0999 V2000<br> 5.3830 3.0953 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1509 -2.0953 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8830 0.9047 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.9820 1.3386 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.7840 1.3385 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7595 2.3135 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0170 -0.5953 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8830 -0.0953 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0169 -1.5953 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3830 3.0953 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0065 2.3135 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.2295 0.6184 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.7690 2.6358 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5365 0.6184 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.9970 2.6358 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.2318 0.9177 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 1.9333 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.5342 0.9177 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7660 1.9332 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1509 -3.0953 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.2849 -1.5953 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.8049 -0.0127 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4064 -0.7030 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4199 -0.4053 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2290 -2.1779 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.6275 -1.4877 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5210 3.6998 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.8244 3.3643 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.3744 0.0156 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.6380 3.2418 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3916 0.0155 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1280 3.2418 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.7789 0.4943 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4083 2.1183 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.9871 0.4942 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.3578 2.1182 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5309 -3.0953 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1509 -3.7153 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7709 -3.0953 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5949 -1.0584 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.7480 -1.2853 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.9749 -2.1322 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 10 1 0 0 0 0<br> 1 11 1 0 0 0 0<br> 2 9 1 0 0 0 0<br> 2 20 1 0 0 0 0<br> 2 21 1 0 0 0 0<br> 3 4 1 0 0 0 0<br> 3 5 1 0 0 0 0<br> 3 8 2 0 0 0 0<br> 4 6 1 0 0 0 0<br> 4 12 2 0 0 0 0<br> 5 11 1 0 0 0 0<br> 5 14 2 0 0 0 0<br> 6 10 1 0 0 0 0<br> 6 13 2 0 0 0 0<br> 7 8 1 0 0 0 0<br> 7 9 1 0 0 0 0<br> 7 22 1 0 0 0 0<br> 7 23 1 0 0 0 0<br> 8 24 1 0 0 0 0<br> 9 25 1 0 0 0 0<br> 9 26 1 0 0 0 0<br> 10 27 1 0 0 0 0<br> 10 28 1 0 0 0 0<br> 11 15 2 0 0 0 0<br> 12 16 1 0 0 0 0<br> 12 29 1 0 0 0 0<br> 13 17 1 0 0 0 0<br> 13 30 1 0 0 0 0<br> 14 18 1 0 0 0 0<br> 14 31 1 0 0 0 0<br> 15 19 1 0 0 0 0<br> 15 32 1 0 0 0 0<br> 16 17 2 0 0 0 0<br> 16 33 1 0 0 0 0<br> 17 34 1 0 0 0 0<br> 18 19 2 0 0 0 0<br> 18 35 1 0 0 0 0<br> 19 36 1 0 0 0 0<br> 20 37 1 0 0 0 0<br> 20 38 1 0 0 0 0<br> 20 39 1 0 0 0 0<br> 21 40 1 0 0 0 0<br> 21 41 1 0 0 0 0<br> 21 42 1 0 0 0 0<br>M END
Compound Name
Doxepin
CID
667477
Molecular Formula
C19H21NO
Molecular Weight
279
No. Hydrogen Bond Acceptors
2
Similar Applications
Reversed Phase
USP Doxepin Assay - Standard Solution on Kinetex® 2.6 µm C8 75 x 4.6 mm
Kinetex 2.6 µm C8 100 Å, LC Column 75 x 4.6 mm, Ea
26361
Reversed Phase
USP Doxepin Assay - Standard Solution on Kinetex® 5 µm C8 150 x 4.6 mm
Kinetex 5 µm C8 100 Å, LC Column 150 x 4.6 mm, Ea
26360
Reversed Phase
USP Doxepin Assay - Standard Solution on Luna 5 µm C8(2) 150 x 4.6 mm
Luna 5 µm C8(2) 100 Å, LC Column 150 x 4.6 mm, Ea
26359
Reversed Phase
Fast Screening Method for 86 Forensic Analytes in Human Urine by LC-MS/MS
Luna 5 µm C18(2) 100 Å, LC Column 50 x 2 mm, Ea
25864
Reversed Phase
Tricyclic Antidepressants Panel by LC-MS/MS with Kinetex 2.6 um PS C18
Kinetex 2.6 µm PS C18 100 Å, LC Column 100 x 2.1 mm, Ea
25493
Reversed Phase
TCA's UV Kinetex 1.7µm C18 50x2.1mm Acquity UPLC
Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19310
Reversed Phase
TCA's LC/MS/MS Kinetex 1.7µm C18 50x2.1mm Agilent 1200
Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19309
Reversed Phase
TCA's LC/MS/MS Kinetex 1.7µm C18 50x2.1mm Agilent 1200
Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19308
Reversed Phase
TCA's LC/MS/MS Kinetex 1.7µm C18 50x2.1mm Agilent 1200
Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19307
Reversed Phase
TCA's LC/MS/MS Kinetex 1.7µm C18 50x2.1mm Agilent 1200
Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19306
Standard
Antidepressants (Underivatized) on ZB-1701, 15 m x 0.25 mm x 0.25 µm
Zebron ZB-1701, GC Cap. Column 15 m x 0.25 mm x 0.25 µm, Ea
19295
Reversed Phase
MercuryMS - Luna 3µm C18(2) 20 x 2.0mm (mini column) for Tricyclics in Plasma by LC/MS/MS
Luna 3 µm C18(2) 100 Å, LC Column 20 x 2 mm, Ea
16043
MercuryMS - Synergi 2.5µm Fusion-RP 20 x 2.0mm for Tricyclics in Plasma by LC/MS/MS
16041