Atenolol on Lux 5µm Cellulose-1 by SFC
LC Conditions
Column
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4459-E0
Phase Name
Cellulose-1
Elution Type
Isocratic
Mobile Phase
A: CO2/(Methanol + 0.1% IPA + 0.1% TFA) 80:20 (v/v)
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
3.00 mL/min
Temperature
30°C
Detection
UV-Vis Abs.-Diode Array (PDA) @ (30°C)
Detection Info
Sample Notes
Courtesy of Katrijn De Klerck, Debby Mangelings and Yvan Vander Heyden, Department of Analytical Chemistry and Pharmaceutical Technology, Vrije Universiteit Brussel, Brussels, Belgium. Results of this analysis yielded: Alpha >1.1 and Resolution >1.5 SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-1, 4 x 3.0mm ID, 10/Pk Part No.: AJ0-8403 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Atenolol
- 2. Atenolol
-OEChem-06211003142D<br><br> 41 41 0 1 0 0 0 0 0999 V2000<br> 5.4641 -0.6550 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -2.6550 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 3.3450 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -3.6550 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 4.8450 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.6550 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -2.1550 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 2.8660 -4.1550 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.1550 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -5.1550 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -3.6550 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 0.3450 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 2.3450 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 0.8450 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 0.8450 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 1.8450 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 1.8450 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 3.3450 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 3.8450 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.5200 -2.0724 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1215 -2.7627 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -3.0050 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 -4.4650 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -3.9650 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3860 -0.5724 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.9875 -1.2627 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.2460 -5.1550 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -5.7750 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4860 -5.1550 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3100 -3.1181 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -3.3450 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.6900 -4.1919 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -3.2750 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8671 0.5350 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0611 0.5350 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8671 2.1550 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0611 2.1550 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2520 3.9276 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8535 3.2373 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8671 5.1550 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.7932 5.1550 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 9 1 0 0 0 0<br> 1 12 1 0 0 0 0<br> 2 7 1 0 0 0 0<br> 2 33 1 0 0 0 0<br> 3 19 2 0 0 0 0<br> 4 6 1 0 0 0 0<br> 4 8 1 0 0 0 0<br> 4 24 1 0 0 0 0<br> 5 19 1 0 0 0 0<br> 5 40 1 0 0 0 0<br> 5 41 1 0 0 0 0<br> 6 7 1 0 0 0 0<br> 6 20 1 0 0 0 0<br> 6 21 1 0 0 0 0<br> 7 9 1 0 0 0 0<br> 7 22 1 0 0 0 0<br> 8 10 1 0 0 0 0<br> 8 11 1 0 0 0 0<br> 8 23 1 0 0 0 0<br> 9 25 1 0 0 0 0<br> 9 26 1 0 0 0 0<br> 10 27 1 0 0 0 0<br> 10 28 1 0 0 0 0<br> 10 29 1 0 0 0 0<br> 11 30 1 0 0 0 0<br> 11 31 1 0 0 0 0<br> 11 32 1 0 0 0 0<br> 12 14 2 0 0 0 0<br> 12 15 1 0 0 0 0<br> 13 16 2 0 0 0 0<br> 13 17 1 0 0 0 0<br> 13 18 1 0 0 0 0<br> 14 16 1 0 0 0 0<br> 14 34 1 0 0 0 0<br> 15 17 2 0 0 0 0<br> 15 35 1 0 0 0 0<br> 16 36 1 0 0 0 0<br> 17 37 1 0 0 0 0<br> 18 19 1 0 0 0 0<br> 18 38 1 0 0 0 0<br> 18 39 1 0 0 0 0<br>M END
Compound Name
Atenolol
CID
2249
Molecular Formula
C14H22N2O3
Molecular Weight
266
No. Hydrogen Bond Acceptors
4
No. Hydrogen Bond Donors
3
Similar Applications
Reversed Phase
Beta-blockers using Luna Omega Polar C18 50x2.1mm
Luna Omega 1.6µm Polar C18 100Å, LC Column 50 x 2.1 mm, EA
23611
Chiral
Atenolol on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21034
Chiral
Atenolol on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21033
Chiral
Atenolol on Lux 5µm Cellulose-1 in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
20547
Chiral
Atenolol on Lux 5µm Cellulose-4 in NP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
20536
Chiral
Atenolol on Lux 5µm Cellulose-2 in PO
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20355
Chiral
Chiral HPLC Purification of Atenolol on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 21.2 mm, AXIA Packed, Ea
19269
Chiral
Chiral SFC Purification of Atenolol on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 21.2 mm, AXIA Packed, Ea
19266
Chiral
Atenolol on Lux 5 µm Cellulose-1 by Chiral SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
19100
Chiral
Atenolol on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17382