Ephedrine on Lux 5µm Cellulose-2 by SFC

Ephedrine on Lux 5µm Cellulose-2 by SFC
LC Conditions
Column

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

Brand

Lux

Part No

00G-4457-E0

Phase Name

Cellulose-2

Elution Type

Isocratic

Mobile Phase

A: CO2/(Methanol + 0.5% IPA) 80:20 (v/v)

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

100

0

Flow Rate

3.00 mL/min

Temperature

30°C

Detection

UV-Vis Abs.-Diode Array (PDA) @ (30°C)

Detection Info
Sample Notes

Courtesy of Katrijn De Klerck, Debby Mangelings and Yvan Vander Heyden, Department of Analytical Chemistry and Pharmaceutical Technology, Vrije Universiteit Brussel, Brussels, Belgium. Results of this analysis yielded: Alpha >1.1 and Resolution >1.5 SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-2, 4 x 3.0mm ID, 10/Pk Part No.: AJ0-8366 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
00G-4457-E0

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

View Product

  • 1. Ephedrine
  • 2. Ephedrine
-OEChem-06211003152D<br><br> 27 27  0     1  0  0  0  0  0999 V2000<br>    2.0000    1.0000    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    2.0000    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    1.0000    0.0000 C   0  0  3  0  0  0  0  0  0  0  0  0<br>    2.8660    0.5000    0.0000 C   0  0  3  0  0  0  0  0  0  0  0  0<br>    2.8660   -0.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    0.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -1.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -1.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    2.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -2.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -2.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -2.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.4682    1.4250    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    1.3500    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2881   -0.0369    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350    0.1900    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.9081    1.0369    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.1951    2.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -0.6900    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -0.6900    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    1.6200    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.9081    1.9631    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350    2.8100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2881    3.0369    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -2.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -2.3100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -3.1200    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  4  1  0  0  0  0<br>  1 21  1  0  0  0  0<br>  2  3  1  0  0  0  0<br>  2  9  1  0  0  0  0<br>  2 18  1  0  0  0  0<br>  3  4  1  0  0  0  0<br>  3  6  1  0  0  0  0<br>  3 13  1  0  0  0  0<br>  4  5  1  0  0  0  0<br>  4 14  1  0  0  0  0<br>  5  7  2  0  0  0  0<br>  5  8  1  0  0  0  0<br>  6 15  1  0  0  0  0<br>  6 16  1  0  0  0  0<br>  6 17  1  0  0  0  0<br>  7 10  1  0  0  0  0<br>  7 19  1  0  0  0  0<br>  8 11  2  0  0  0  0<br>  8 20  1  0  0  0  0<br>  9 22  1  0  0  0  0<br>  9 23  1  0  0  0  0<br>  9 24  1  0  0  0  0<br> 10 12  2  0  0  0  0<br> 10 25  1  0  0  0  0<br> 11 12  1  0  0  0  0<br> 11 26  1  0  0  0  0<br> 12 27  1  0  0  0  0<br>M  END
Compound Name

Ephedrine

CID

5032

Molecular Formula

C10H15NO

Molecular Weight

165

No. Hydrogen Bond Acceptors

2

No. Hydrogen Bond Donors

2

Similar Applications

Chiral

Chiral Amphetamines with Ephedrines & Pseudoephedrines on Lux 3µm AMP 150x3mm

Lux 3 µm AMP, LC Column 150 x 3.0 mm, EA

23640

Chiral

Norephedrine on LUX Amylose-1 5u 250x4.6mm in PO

Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA

23191

Reversed Phase

Antihistamines on Kinetex 2.6u F5 50x4.6mm at pH 2.9 and pH 7.2

Kinetex 2.6 µm F5 100 Å, LC Column 50 x 4.6 mm, Ea

22838

Reversed Phase

Antihistamines using Kinetex 5u EVO C18 150x4.6mm

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

22716

Chiral

Ephedrine on Lux 5µm Cellulose-2 by SFC

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

21116

Chiral

Ephedrine on Lux 5µm Cellulose-2 by SFC

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

21115

Chiral

Ephedrine on Lux 5µm Cellulose-1 by SFC

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

21114