Mianserine on Lux 5µm Cellulose-3 by SFC
LC Conditions
Column
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4493-E0
Phase Name
Cellulose-3
Elution Type
Isocratic
Mobile Phase
A: CO2/(Methanol + 0.5% IPA) 80:20 (v/v)
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
3.00 mL/min
Temperature
30°C
Detection
UV-Vis Abs.-Diode Array (PDA) @ (30°C)
Detection Info
Sample Notes
Courtesy of Katrijn De Klerck, Debby Mangelings and Yvan Vander Heyden, Department of Analytical Chemistry and Pharmaceutical Technology, Vrije Universiteit Brussel, Brussels, Belgium. Results of this analysis yielded: Alpha >1.1 and Resolution >1.5 SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-3, 4 x 3.0mm ID, 10/Pk Part No.: AJ0-8622 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Mianserin
- 2. Mianserin
-OEChem-06211003152D<br><br> 40 43 0 1 0 0 0 0 0999 V2000<br> 4.5438 -0.7951 0.0000 N 0 0 3 0 0 0 0 0 0 0 0 0<br> 2.8430 -1.9740 0.0000 N 0 0 3 0 0 0 0 0 0 0 0 0<br> 3.6428 -0.3612 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 2.7732 -0.9347 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.6376 -1.8325 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4203 0.6137 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7815 -2.4259 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4447 -0.3612 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0438 1.3955 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.0438 1.3955 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6673 0.6137 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0146 -2.5341 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3880 0.7530 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.1973 -1.0814 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.6782 2.3709 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.6578 0.9360 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 1.7197 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.6494 2.5341 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1950 -0.7821 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.4268 0.2334 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.0674 -0.1303 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5255 -0.3663 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.1708 -1.0815 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8984 -2.3950 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2364 -1.6718 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4209 -2.9302 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2167 -2.8675 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6024 1.6645 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9058 2.0000 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.6674 -2.0205 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.5010 -2.8814 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3619 -3.0477 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0071 0.2639 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0524 -1.6842 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0704 2.8511 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7887 1.5420 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.3866 1.8098 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.4252 3.1121 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.6478 -1.2055 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0185 0.4185 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 3 1 0 0 0 0<br> 1 5 1 0 0 0 0<br> 1 8 1 0 0 0 0<br> 2 4 1 0 0 0 0<br> 2 7 1 0 0 0 0<br> 2 12 1 0 0 0 0<br> 3 4 1 0 0 0 0<br> 3 6 1 0 0 0 0<br> 3 21 1 0 0 0 0<br> 4 22 1 0 0 0 0<br> 4 23 1 0 0 0 0<br> 5 7 1 0 0 0 0<br> 5 24 1 0 0 0 0<br> 5 25 1 0 0 0 0<br> 6 9 1 0 0 0 0<br> 6 13 2 0 0 0 0<br> 7 26 1 0 0 0 0<br> 7 27 1 0 0 0 0<br> 8 11 1 0 0 0 0<br> 8 14 2 0 0 0 0<br> 9 10 1 0 0 0 0<br> 9 15 2 0 0 0 0<br> 10 11 1 0 0 0 0<br> 10 28 1 0 0 0 0<br> 10 29 1 0 0 0 0<br> 11 16 2 0 0 0 0<br> 12 30 1 0 0 0 0<br> 12 31 1 0 0 0 0<br> 12 32 1 0 0 0 0<br> 13 17 1 0 0 0 0<br> 13 33 1 0 0 0 0<br> 14 19 1 0 0 0 0<br> 14 34 1 0 0 0 0<br> 15 18 1 0 0 0 0<br> 15 35 1 0 0 0 0<br> 16 20 1 0 0 0 0<br> 16 36 1 0 0 0 0<br> 17 18 2 0 0 0 0<br> 17 37 1 0 0 0 0<br> 18 38 1 0 0 0 0<br> 19 20 2 0 0 0 0<br> 19 39 1 0 0 0 0<br> 20 40 1 0 0 0 0<br>M END
Compound Name
Mianserin
CID
4184
Molecular Formula
C18H20N2
Molecular Weight
264
No. Hydrogen Bond Acceptors
2
Similar Applications
Chiral
Chiral Separation of Mianserin on Lux 5µm i-Amylose-1 in NP
Lux 5 µm i-Amylose-1, LC Column 250 x 4.6 mm, Ea
24295
Chiral
Chiral Separation of Mianserin on Lux 5µm i-Amylose-1 Stability (After aggressive solvent exposure)
Lux 5 µm i-Amylose-1, LC Column 250 x 4.6 mm, Ea
24281
Chiral
Chiral Separation of Mianserin on Lux 5µm i-Amylose-1 Stability (Before aggressive solvent exposure)
Lux 5 µm i-Amylose-1, LC Column 250 x 4.6 mm, Ea
24280
Chiral
Mianserine on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23338
Chiral
Mianserine on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23332
Chiral
Mianserine on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23323
Chiral
Mianserine on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23315
Chiral
Mianserine on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23300
Chiral
Mianserine on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23294
Chiral
Mianserine on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23289
Chiral
Mianserin on LUX Amylose-1 5u in RP
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23200
Chiral
Mianserin on LUX Amylose-1 5u 250x4.6mm in PO
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23196
Chiral
Mianserin on LUX Amylose-1 5u 250x4.6mm in PO
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23194
Chiral
Mianserine on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21235
Chiral
Mianserine on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21234
Chiral
Mianserine on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21233
Chiral
Mianserine on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21232
Chiral
Mianserine on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21231
Chiral
Mianserine on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21230
Chiral
Mianserine on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21229
Chiral
Mianserine on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21228
Chiral
Mianserine on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21227
Chiral
Mianserine on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21226
Chiral
Mianserine on Lux 5µm Cellulose-2 by SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21225
Chiral
Mianserine on Lux 5µm Cellulose-2 by SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21224
Chiral
Mianserine on Lux 5µm Cellulose-2 by SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21223
Chiral
Mianserine on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21222
Chiral
Mianserine on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21221
Chiral
Mianserine on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21220
Chiral
Mianserine on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21219
Chiral
Mianserine on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21218
Chiral
Mianserin on Lux 5µm Cellulose-1 in RP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
20225
Chiral
Mianserin on Lux 5µm Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17477
Chiral
Mianserin on Lux 3µm Cellulose-1
Lux 3 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17471
Chiral
Mianserin on Lux Cellulose-2
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17433
Chiral
Mianserin on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17432