Pindolol on Lux 5µm Cellulose-3 by SFC
LC Conditions
Column
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4493-E0
Phase Name
Cellulose-3
Elution Type
Isocratic
Mobile Phase
A: CO2/(Methanol + 0.5% IPA) 90:10 (v/v)
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
3.00 mL/min
Temperature
30°C
Detection
UV-Vis Abs.-Diode Array (PDA) @ (30°C)
Detection Info
Sample Notes
Courtesy of Katrijn De Klerck, Debby Mangelings and Yvan Vander Heyden, Department of Analytical Chemistry and Pharmaceutical Technology, Vrije Universiteit Brussel, Brussels, Belgium. Results of this analysis yielded: Alpha >1.1 and Resolution >1.5 SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-3, 4 x 3.0mm ID, 10/Pk Part No.: AJ0-8622 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Pindolol
- 2. Pindolol
-OEChem-06211003152D<br><br> 38 39 0 1 0 0 0 0 0999 V2000<br> 5.4641 -0.5530 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 1.4470 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 2.4470 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.2764 -3.3577 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 0.9470 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 3.7320 1.4470 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 2.9470 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -0.0530 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -2.0530 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -1.5530 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 3.9470 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 2.4470 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -3.0530 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.2764 -1.7482 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -2.0530 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -3.5530 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.8600 -2.5530 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -3.0530 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 1.5670 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1215 1.5547 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.5200 0.8644 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 2.3270 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 2.7570 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.9875 0.0547 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3860 -0.6356 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4860 3.9470 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 4.5670 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.2460 3.9470 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.6900 2.9840 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 2.1370 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3100 1.9101 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.4690 -1.1589 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0611 -1.7430 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 2.0670 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.4690 -3.9470 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -4.1730 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.4800 -2.5530 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0611 -3.3630 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 8 1 0 0 0 0<br> 1 10 1 0 0 0 0<br> 2 5 1 0 0 0 0<br> 2 34 1 0 0 0 0<br> 3 6 1 0 0 0 0<br> 3 7 1 0 0 0 0<br> 3 23 1 0 0 0 0<br> 4 13 1 0 0 0 0<br> 4 17 1 0 0 0 0<br> 4 35 1 0 0 0 0<br> 5 6 1 0 0 0 0<br> 5 8 1 0 0 0 0<br> 5 19 1 0 0 0 0<br> 6 20 1 0 0 0 0<br> 6 21 1 0 0 0 0<br> 7 11 1 0 0 0 0<br> 7 12 1 0 0 0 0<br> 7 22 1 0 0 0 0<br> 8 24 1 0 0 0 0<br> 8 25 1 0 0 0 0<br> 9 10 1 0 0 0 0<br> 9 13 2 0 0 0 0<br> 9 14 1 0 0 0 0<br> 10 15 2 0 0 0 0<br> 11 26 1 0 0 0 0<br> 11 27 1 0 0 0 0<br> 11 28 1 0 0 0 0<br> 12 29 1 0 0 0 0<br> 12 30 1 0 0 0 0<br> 12 31 1 0 0 0 0<br> 13 16 1 0 0 0 0<br> 14 17 2 0 0 0 0<br> 14 32 1 0 0 0 0<br> 15 18 1 0 0 0 0<br> 15 33 1 0 0 0 0<br> 16 18 2 0 0 0 0<br> 16 36 1 0 0 0 0<br> 17 37 1 0 0 0 0<br> 18 38 1 0 0 0 0<br>M END
Compound Name
Pindolol
CID
4828
Molecular Formula
C14H20N2O2
Molecular Weight
248
No. Hydrogen Bond Acceptors
3
No. Hydrogen Bond Donors
3
Similar Applications
Reversed Phase
Beta-blockers using Luna Omega 1.6u PS C18 50x2.1mm
Luna Omega 1.6µm PS C18 100Å, LC Column 50 x 2.1 mm, EA
23727
Reversed Phase
ABN7 on Luna Omega 1.6u PS C18 50x2.1mm
Luna Omega 1.6µm PS C18 100Å, LC Column 50 x 2.1 mm, EA
23707
Reversed Phase
Beta-blockers using Luna Omega Polar C18 50x2.1mm
Luna Omega 1.6µm Polar C18 100Å, LC Column 50 x 2.1 mm, EA
23611
Chiral
Pindolol on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23290
Chiral
Pindolol on LUX Amylose-1 5u 250x4.6mm in PO
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23182
Reversed Phase
ABN6 Mix on Kinetex 1.7u EVO C18 50x2.1mm
Kinetex 1.7 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, Ea
23068
Reversed Phase
Pharmaceutical Mix on Kinetex 1.7 F5 50x2.1mm
Kinetex 1.7 µm F5 100 Å, LC Column 50 x 2.1 mm, Ea
22813
Reversed Phase
Batch Reproducibility with ABN 7 mix- Kinetex 2.6u F5 50x4.6mm
Kinetex 2.6 µm F5 100 Å, LC Column 50 x 4.6 mm, Ea
22803
Reversed Phase
Batch reproducibility of Kinetex 5u EVO C18 150x4.6mm
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
22734
Reversed Phase
Pharma ABN Mixture using Kinetex 5u EVO C18 150x4.6mm
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
22718
Chiral
Pindolol on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21311
Chiral
Pindolol on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21310
Chiral
Pindolol on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21309
Chiral
Pindolol on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21308
Chiral
Pindolol on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21307
Chiral
Pindolol on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21306
Chiral
Pindolol on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21305
Chiral
Pindolol on Lux 5µm Cellulose-2 by SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21304
Chiral
Pindolol on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21303
Chiral
Pindolol on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21302
Chiral
Mepindolol on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21189
Chiral
Mepindolol on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21188
Chiral
Mepindolol on Lux 5µm Cellulose-2 by SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21187
Chiral
Mepindolol on Lux 5µm Cellulose-2 by SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21186
Chiral
Mepindolol on Lux 5µm Cellulose-2 by SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21185
Chiral
Bopindolol on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21065
Chiral
Bopindolol on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21064
Chiral
Bopindolol on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21063
Chiral
Bopindolol on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21062
Chiral
Bopindolol on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21061
Chiral
Bopindolol on Lux 5µm Cellulose-2 by SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21060
Chiral
Bopindolol on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21059
Chiral
Bopindolol on Lux 5µm Cellulose-2 in NP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20492
Chiral
Pindolol on Lux 5µm Cellulose-3 in NP
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
20466
Chiral
Pindolol on Lux 5µm Cellulose-4 in NP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
20350
Chiral
Pindolol on Lux 5µm Cellulose-1 in RP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
20198
Chiral
Bopindolol on Lux 5µm Cellulose-4 in RP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
20173
Chiral
Pindolol on Lux 5µm Cellulose-2 in NP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20125
Reversed Phase
Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 1.7u C18 100x2.1mm @ 0.60mL/min
Kinetex 1.7 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
20054
Reversed Phase
Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 2.6u C18 100x2.1mm @ 0.60mL/min
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
20053
Reversed Phase
Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 2.6 C18 100x2.1mm @ 1.0mL/min
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
20050
Reversed Phase
Pharma ABN Test 15 Mix on Un-Optimized Agilent 1100 system using Kinetex 2.6u C18 100x4.6mm
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea
20049
Reversed Phase
Pharma ABN Test 15 Mix on Optimized Agilent 1100 system using Kinetex 2.6u C18 100x4.6mm
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea
20048
Reversed Phase
Pharmaceutical Drug Mix on Kinetex 2.6 µm C18 50 x 2.1mm @ 0.8 mL/min(Quotient Data)
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19944
Reversed Phase
Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotien Data)
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19941
Reversed Phase
Pharmaceutical Drug Mix on Kinetex C18 2.6u 100 x 2.1mm @ 0.85 mL/min(Quotient Data)
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
19940
Reversed Phase
Pharmaceutical Drug Mix on Kinetex C18 2.6u 75 x 2.1mm @ 1.1 mL/min(Quotient Data)
Kinetex 2.6 µm C18 100 Å, LC Column 75 x 2.1 mm, Ea
19939
Reversed Phase
Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotient Data)
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19914
Reversed Phase
Pharmaceutical Drug Mix on Kinetex 2.6 µm C18 50 x 2.1mm @ 0.8 mL/min(Quotient Data)
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19911
Reversed Phase
Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotient Data)
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19862
Reversed Phase
Pharmaceutical Mixture on Kinetex 2.6µm C8 50x2.1mm ID
Kinetex 2.6 µm C8 100 Å, LC Column 50 x 2.1 mm, Ea
19476
Reversed Phase
Pharmaceutical Mixture on Kinetex XB-C18
Kinetex 2.6 µm XB-C18 100 Å, LC Column 50 x 2.1 mm, Ea
19475
Reversed Phase
Pharmaceutical Mixture on Kinetex C18
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19474
Chiral
Bopindolol on Lux 5µm Cellulose-1 in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
19193
Chiral
Bopindolol on Lux 5 µm Cellulose-1 by Chiral SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
18861
Chiral
Bopindolol on Lux 5 µm Cellulose-2 by Chiral SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
18860
Chiral
Pindolol on Lux 5µ Cellulose-2 in RP 20% CH3CN
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17868
Chiral
Pindolol on Lux 5µ Cellulose-2 in RP 60%MeOH
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17865
Chiral
Pindolol on Lux 5µ Cellulose-1 in RP 80% MeOH-2
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17864
Chiral
Pindolol on Lux 5µ Cellulose-1 in RP 80% MeOH-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17863
Chiral
Pindolol on Lux 5µ Cellulose-1 in RP 60% CH3CN
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17862
Chiral
Pindolol on Lux 5µ Cellulose-1 in RP 40% CH3CN
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17861
Chiral
Bopindolol on Lux Cellulose-2
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17484
Chiral
Bopindolol on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17483
Chiral
Pindolol on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17384
Chiral
Bopindolol on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
16715