Triadimefon on Lux 5µm Cellulose-2 in NP

Triadimefon on Lux 5µm Cellulose-2 in NP
LC Conditions
Column

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

Brand

Lux

Part No

00G-4457-E0

Phase Name

Cellulose-2

Elution Type

Isocratic

Mobile Phase

A: Hexane / IPA (80:20) DEA (0.1%)

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

100

0

Flow Rate

1.00 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info

Order Items Used in This Application

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
00G-4457-E0

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

View Product

  • 1. Triadimefon
  • 2. Triadimefon
-OEChem-05081000432D<br><br> 36 37  0     1  0  0  0  0  0999 V2000<br>    2.8660   -3.5194    0.0000 Cl  0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    0.4806    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -0.5194    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    1.9806    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5411    2.5684    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.2320    3.5194    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641    0.9806    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    0.4806    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    0.9806    0.0000 C   0  0  3  0  0  0  0  0  0  0  0  0<br>    6.3301    1.4806    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.9641    0.1146    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.9641    1.8466    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -0.5194    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.9230    2.5684    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -1.0194    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -1.0194    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2320    3.5194    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -2.0194    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -2.0194    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -2.5194    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    0.1306    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.6401    0.9436    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.8671    1.7906    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0201    2.0175    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4272   -0.1954    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.2741   -0.4224    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.5010    0.4246    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.5010    2.1566    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.6541    2.3835    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.4272    1.5366    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3334    2.3768    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -0.7094    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -0.7094    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5965    4.0210    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -2.3294    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -2.3294    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1 20  1  0  0  0  0<br>  2  9  1  0  0  0  0<br>  2 13  1  0  0  0  0<br>  3  8  2  0  0  0  0<br>  4  5  1  0  0  0  0<br>  4  9  1  0  0  0  0<br>  4 14  1  0  0  0  0<br>  5 17  2  0  0  0  0<br>  6 14  2  0  0  0  0<br>  6 17  1  0  0  0  0<br>  7  8  1  0  0  0  0<br>  7 10  1  0  0  0  0<br>  7 11  1  0  0  0  0<br>  7 12  1  0  0  0  0<br>  8  9  1  0  0  0  0<br>  9 21  1  0  0  0  0<br> 10 22  1  0  0  0  0<br> 10 23  1  0  0  0  0<br> 10 24  1  0  0  0  0<br> 11 25  1  0  0  0  0<br> 11 26  1  0  0  0  0<br> 11 27  1  0  0  0  0<br> 12 28  1  0  0  0  0<br> 12 29  1  0  0  0  0<br> 12 30  1  0  0  0  0<br> 13 15  2  0  0  0  0<br> 13 16  1  0  0  0  0<br> 14 31  1  0  0  0  0<br> 15 18  1  0  0  0  0<br> 15 32  1  0  0  0  0<br> 16 19  2  0  0  0  0<br> 16 33  1  0  0  0  0<br> 17 34  1  0  0  0  0<br> 18 20  2  0  0  0  0<br> 18 35  1  0  0  0  0<br> 19 20  1  0  0  0  0<br> 19 36  1  0  0  0  0<br>M  END
Compound Name

Triadimefon

CID

39385

Molecular Formula

C14H16ClN3O2

Molecular Weight

293

No. Hydrogen Bond Acceptors

4

Similar Applications

Reversed Phase

Pesticide panel using Kinetex 2.6u Polar C18 50x4.6mm

Kinetex 2.6 µm Polar C18 100 Å, LC Column 50 x 4.6 mm, Ea

24017

Reversed Phase

185 Pesticides on Kinetex Biphenyl 5u

Kinetex 5 µm Biphenyl 100 Å, LC Column 100 x 2.1 mm, Ea

22618

Chiral

Triadimefon on Lux 5µm Cellulose-4 in RP

Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea

21844

Chiral

Triadimefon on Lux 5µm Cellulose-2 in RP

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

21843

Chiral

Triadimefon on Lux 5µm Cellulose-2 in RP

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

21842

Chiral

Triadimefon on Lux 5µm Cellulose-1 in RP

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

21841

Chiral

Triadimefon on Lux 5µm Cellulose-2 in NP

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

21738

Chiral

Triadimefon on Lux 5µm Cellulose-1 in NP

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

21737

Application Specific

EPA Method 525.2 on ZB-SemiVolatiles

Zebron ZB-SemiVolatiles, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

21438

Standard

Nitrogen Pesticides - EPA Method 633 on ZB5ms 30x0.25x0.25

Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

15446

Standard

Nitrogen and Phosphorous Pesticides - EPA Method 507 on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

15445

Standard

Nitrogen and Phosphorous Pesticides on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

15439

Standard

EPA Method 525.2: Organic compounds in Drinking Water on ZB-5 on ZB-5

Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea