Difenoconazole on Lux 5µm Cellulose-3 in RP
LC Conditions
Column
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4493-E0
Phase Name
Cellulose-3
Elution Type
Isocratic
Mobile Phase
A: ACN / 20mM NH4HCO3+0.1%DEA (40:60) DEA (0.1%)
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Order Items Used in This Application
- 1. Difenoconazole
- 2. Difenoconazole
- 3. Difenoconazole
- 4. Difenoconazole
-OEChem-04281015272D<br><br> 44 47 0 1 0 0 0 0 0999 V2000<br> 3.4403 1.1193 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.6364 -3.8807 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.1724 2.1193 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8633 3.0704 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1724 -1.8807 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4782 2.4794 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5000 2.2715 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.6691 3.8807 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1724 2.1193 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 6.4814 3.0704 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 4.2213 1.8103 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6724 3.6582 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1724 1.1193 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.4324 3.3794 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3063 0.6193 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0384 0.6193 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3063 -0.3807 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0384 -0.3807 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1724 -0.8807 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.5827 3.4740 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 3.1375 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0384 -2.3807 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.9044 -1.8807 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0384 -3.3807 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7704 -2.3807 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.9044 -3.8807 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7704 -3.3807 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.0824 2.4693 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7327 1.4286 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5124 1.2629 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0872 4.1189 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2575 4.1189 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.6240 2.7897 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0221 3.5710 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.2408 3.9690 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5753 0.9293 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7694 -0.6907 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5753 -0.6907 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.1196 3.7840 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.3834 3.2024 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.9044 -1.2607 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5014 -3.6907 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.3074 -2.0707 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.9044 -4.5007 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 15 1 0 0 0 0<br> 2 27 1 0 0 0 0<br> 3 9 1 0 0 0 0<br> 3 10 1 0 0 0 0<br> 4 9 1 0 0 0 0<br> 4 12 1 0 0 0 0<br> 5 19 1 0 0 0 0<br> 5 22 1 0 0 0 0<br> 6 7 1 0 0 0 0<br> 6 11 1 0 0 0 0<br> 6 20 1 0 0 0 0<br> 7 21 2 0 0 0 0<br> 8 20 2 0 0 0 0<br> 8 21 1 0 0 0 0<br> 9 11 1 0 0 0 0<br> 9 13 1 0 0 0 0<br> 10 12 1 0 0 0 0<br> 10 14 1 0 0 0 0<br> 10 28 1 0 0 0 0<br> 11 29 1 0 0 0 0<br> 11 30 1 0 0 0 0<br> 12 31 1 0 0 0 0<br> 12 32 1 0 0 0 0<br> 13 15 2 0 0 0 0<br> 13 16 1 0 0 0 0<br> 14 33 1 0 0 0 0<br> 14 34 1 0 0 0 0<br> 14 35 1 0 0 0 0<br> 15 17 1 0 0 0 0<br> 16 18 2 0 0 0 0<br> 16 36 1 0 0 0 0<br> 17 19 2 0 0 0 0<br> 17 37 1 0 0 0 0<br> 18 19 1 0 0 0 0<br> 18 38 1 0 0 0 0<br> 20 39 1 0 0 0 0<br> 21 40 1 0 0 0 0<br> 22 23 2 0 0 0 0<br> 22 24 1 0 0 0 0<br> 23 25 1 0 0 0 0<br> 23 41 1 0 0 0 0<br> 24 26 2 0 0 0 0<br> 24 42 1 0 0 0 0<br> 25 27 2 0 0 0 0<br> 25 43 1 0 0 0 0<br> 26 27 1 0 0 0 0<br> 26 44 1 0 0 0 0<br>M END
Compound Name
Difenoconazole
CID
86173
Molecular Formula
C19H17Cl2N3O3
Molecular Weight
406
No. Hydrogen Bond Acceptors
5
Similar Applications
Reversed Phase
Pesticide panel using Kinetex 2.6u Polar C18 50x4.6mm
Kinetex 2.6 µm Polar C18 100 Å, LC Column 50 x 4.6 mm, Ea
24017
Chiral
Difenoconazole on Lux 5µm Cellulose-3 in RP
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21762
Chiral
Difenoconazole on Lux 5µm Cellulose-3 in NP
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21681