Tebuconazole on Lux 5µm Cellulose-2 in RP

Tebuconazole on Lux 5µm Cellulose-2 in RP
LC Conditions
Column

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

Brand

Lux

Part No

00G-4457-E0

Phase Name

Cellulose-2

Elution Type

Isocratic

Mobile Phase

A: ACN / 20mM NH4HCO3+0.1%DEA (50:50) with DEA (0.1%) in buffer

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

100

0

Flow Rate

1.00 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info

Order Items Used in This Application

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
00G-4457-E0

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

View Product

  • 1. Tebuconazole
  • 2. Tebuconazole
-OEChem-04281015272D<br><br> 43 44  0     1  0  0  0  0  0999 V2000<br>    2.8660   -3.7500    0.0000 Cl  0  0  0  0  0  0  0  0  0  0  0  0<br>    2.7320    1.7500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.2320    0.8840    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.2266    0.7794    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.5685   -0.6987    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    1.7500    0.0000 C   0  0  3  0  0  0  0  0  0  0  0  0<br>    3.7320    2.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    0.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.7320    1.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    3.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.7320    2.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.7320    2.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -0.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.8253   -0.0296    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -1.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -1.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.4345   -0.1987    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -2.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -2.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -2.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.9441    0.1674    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.3426    0.8577    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.3147    1.9620    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.6244    2.3606    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.3520    3.7500    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    4.3700    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.1120    3.7500    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.7320    3.3700    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.1120    2.7500    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.7320    2.1300    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.7320    2.1300    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.3520    2.7500    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.7320    3.3700    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.6540    0.8326    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.2554    0.1423    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.4220    1.2131    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2189   -0.1585    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -0.9400    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -0.9400    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.0009   -0.4509    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -2.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -2.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1 21  1  0  0  0  0<br>  2  6  1  0  0  0  0<br>  2 37  1  0  0  0  0<br>  3  4  1  0  0  0  0<br>  3  9  1  0  0  0  0<br>  3 15  1  0  0  0  0<br>  4 18  2  0  0  0  0<br>  5 15  2  0  0  0  0<br>  5 18  1  0  0  0  0<br>  6  7  1  0  0  0  0<br>  6  8  1  0  0  0  0<br>  6  9  1  0  0  0  0<br>  7 10  1  0  0  0  0<br>  7 11  1  0  0  0  0<br>  7 12  1  0  0  0  0<br>  8 13  1  0  0  0  0<br>  8 22  1  0  0  0  0<br>  8 23  1  0  0  0  0<br>  9 24  1  0  0  0  0<br>  9 25  1  0  0  0  0<br> 10 26  1  0  0  0  0<br> 10 27  1  0  0  0  0<br> 10 28  1  0  0  0  0<br> 11 29  1  0  0  0  0<br> 11 30  1  0  0  0  0<br> 11 31  1  0  0  0  0<br> 12 32  1  0  0  0  0<br> 12 33  1  0  0  0  0<br> 12 34  1  0  0  0  0<br> 13 14  1  0  0  0  0<br> 13 35  1  0  0  0  0<br> 13 36  1  0  0  0  0<br> 14 16  2  0  0  0  0<br> 14 17  1  0  0  0  0<br> 15 38  1  0  0  0  0<br> 16 19  1  0  0  0  0<br> 16 39  1  0  0  0  0<br> 17 20  2  0  0  0  0<br> 17 40  1  0  0  0  0<br> 18 41  1  0  0  0  0<br> 19 21  2  0  0  0  0<br> 19 42  1  0  0  0  0<br> 20 21  1  0  0  0  0<br> 20 43  1  0  0  0  0<br>M  END
Compound Name

Tebuconazole

CID

86102

Molecular Formula

C16H22ClN3O

Molecular Weight

307

No. Hydrogen Bond Acceptors

3

No. Hydrogen Bond Donors

1

Similar Applications

Reversed Phase

Pesticide panel using Kinetex 2.6u Polar C18 50x4.6mm

Kinetex 2.6 µm Polar C18 100 Å, LC Column 50 x 4.6 mm, Ea

24017

Reversed Phase

185 Pesticides on Kinetex Biphenyl 5u

Kinetex 5 µm Biphenyl 100 Å, LC Column 100 x 2.1 mm, Ea

22618

Chiral

Tebuconazole on Lux 5µm Cellulose-3 in RP

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

21839

Chiral

Tebuconazole on Lux 5µm Cellulose-4 in RP

Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea

21838

Chiral

Tebuconazole on Lux 5µm Cellulose-4 in RP

Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea

21837

Chiral

Tebuconazole on Lux 5µm Cellulose-2 in RP

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

21836

Chiral

Tebuconazole on Lux 5µm Cellulose-2 in RP

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

21835

Chiral

Tebuconazole on Lux 5µm Cellulose-2 in RP

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

21834

Chiral

Tebuconazole on Lux 5µm Cellulose-3 in NP

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

21736

Tebuconazole on Lux 5µm Amylose-2 in NP

21735

Chiral

Tebuconazole on Lux 5µm Cellulose-4 in NP

Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea

21734

Chiral

Tebuconazole on Lux 5µm Cellulose-2 in NP

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

21733

Chiral

Tebuconazole on Lux 5µm Cellulose-1 in NP

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

21732