Tebuconazole on Lux 5µm Cellulose-2 in RP
LC Conditions
Column
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4457-E0
Phase Name
Cellulose-2
Elution Type
Isocratic
Mobile Phase
A: ACN / 20mM NH4HCO3+0.1%DEA (60:40) with DEA (0.1%) in buffer
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Order Items Used in This Application
- 1. Tebuconazole
- 2. Tebuconazole
-OEChem-04281015272D<br><br> 43 44 0 1 0 0 0 0 0999 V2000<br> 2.8660 -3.7500 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.7320 1.7500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2320 0.8840 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.2266 0.7794 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5685 -0.6987 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.7500 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 3.7320 2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 0.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7320 1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 3.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.7320 2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7320 2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -0.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8253 -0.0296 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.4345 -0.1987 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -2.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.9441 0.1674 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3426 0.8577 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.3147 1.9620 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.6244 2.3606 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3520 3.7500 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 4.3700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1120 3.7500 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.7320 3.3700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.1120 2.7500 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.7320 2.1300 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7320 2.1300 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.3520 2.7500 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7320 3.3700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.6540 0.8326 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.2554 0.1423 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.4220 1.2131 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2189 -0.1585 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -0.9400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -0.9400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.0009 -0.4509 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -2.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -2.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 21 1 0 0 0 0<br> 2 6 1 0 0 0 0<br> 2 37 1 0 0 0 0<br> 3 4 1 0 0 0 0<br> 3 9 1 0 0 0 0<br> 3 15 1 0 0 0 0<br> 4 18 2 0 0 0 0<br> 5 15 2 0 0 0 0<br> 5 18 1 0 0 0 0<br> 6 7 1 0 0 0 0<br> 6 8 1 0 0 0 0<br> 6 9 1 0 0 0 0<br> 7 10 1 0 0 0 0<br> 7 11 1 0 0 0 0<br> 7 12 1 0 0 0 0<br> 8 13 1 0 0 0 0<br> 8 22 1 0 0 0 0<br> 8 23 1 0 0 0 0<br> 9 24 1 0 0 0 0<br> 9 25 1 0 0 0 0<br> 10 26 1 0 0 0 0<br> 10 27 1 0 0 0 0<br> 10 28 1 0 0 0 0<br> 11 29 1 0 0 0 0<br> 11 30 1 0 0 0 0<br> 11 31 1 0 0 0 0<br> 12 32 1 0 0 0 0<br> 12 33 1 0 0 0 0<br> 12 34 1 0 0 0 0<br> 13 14 1 0 0 0 0<br> 13 35 1 0 0 0 0<br> 13 36 1 0 0 0 0<br> 14 16 2 0 0 0 0<br> 14 17 1 0 0 0 0<br> 15 38 1 0 0 0 0<br> 16 19 1 0 0 0 0<br> 16 39 1 0 0 0 0<br> 17 20 2 0 0 0 0<br> 17 40 1 0 0 0 0<br> 18 41 1 0 0 0 0<br> 19 21 2 0 0 0 0<br> 19 42 1 0 0 0 0<br> 20 21 1 0 0 0 0<br> 20 43 1 0 0 0 0<br>M END
Compound Name
Tebuconazole
CID
86102
Molecular Formula
C16H22ClN3O
Molecular Weight
307
No. Hydrogen Bond Acceptors
3
No. Hydrogen Bond Donors
1
Similar Applications
Reversed Phase
Pesticide panel using Kinetex 2.6u Polar C18 50x4.6mm
Kinetex 2.6 µm Polar C18 100 Å, LC Column 50 x 4.6 mm, Ea
24017
Reversed Phase
185 Pesticides on Kinetex Biphenyl 5u
Kinetex 5 µm Biphenyl 100 Å, LC Column 100 x 2.1 mm, Ea
22618
Chiral
Tebuconazole on Lux 5µm Cellulose-3 in RP
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21839
Chiral
Tebuconazole on Lux 5µm Cellulose-4 in RP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21838
Chiral
Tebuconazole on Lux 5µm Cellulose-4 in RP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21837
Chiral
Tebuconazole on Lux 5µm Cellulose-2 in RP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21836
Chiral
Tebuconazole on Lux 5µm Cellulose-2 in RP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21835
Chiral
Tebuconazole on Lux 5µm Cellulose-2 in RP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21834
Chiral
Tebuconazole on Lux 5µm Cellulose-3 in NP
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21736
Tebuconazole on Lux 5µm Amylose-2 in NP
21735
Chiral
Tebuconazole on Lux 5µm Cellulose-4 in NP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21734
Chiral
Tebuconazole on Lux 5µm Cellulose-2 in NP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21733
Chiral
Tebuconazole on Lux 5µm Cellulose-1 in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21732