Triadimefon on Lux 5µm Cellulose-1 in RP
LC Conditions
Column
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4459-E0
Phase Name
Cellulose-1
Elution Type
Isocratic
Mobile Phase
A: ACN / 20mM NH4HCO3+0.1%DEA (50:50) DEA (0.1%)
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Order Items Used in This Application
- 1. Triadimefon
- 2. Triadimefon
-OEChem-05081000432D<br><br> 36 37 0 1 0 0 0 0 0999 V2000<br> 2.8660 -3.5194 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 0.4806 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -0.5194 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.9806 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5411 2.5684 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.2320 3.5194 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 0.9806 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 0.4806 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 0.9806 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 6.3301 1.4806 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.9641 0.1146 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9641 1.8466 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -0.5194 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.9230 2.5684 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.0194 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -1.0194 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2320 3.5194 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.0194 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -2.0194 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -2.5194 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 0.1306 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.6401 0.9436 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8671 1.7906 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0201 2.0175 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4272 -0.1954 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.2741 -0.4224 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5010 0.4246 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5010 2.1566 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.6541 2.3835 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.4272 1.5366 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3334 2.3768 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -0.7094 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -0.7094 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5965 4.0210 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -2.3294 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -2.3294 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 20 1 0 0 0 0<br> 2 9 1 0 0 0 0<br> 2 13 1 0 0 0 0<br> 3 8 2 0 0 0 0<br> 4 5 1 0 0 0 0<br> 4 9 1 0 0 0 0<br> 4 14 1 0 0 0 0<br> 5 17 2 0 0 0 0<br> 6 14 2 0 0 0 0<br> 6 17 1 0 0 0 0<br> 7 8 1 0 0 0 0<br> 7 10 1 0 0 0 0<br> 7 11 1 0 0 0 0<br> 7 12 1 0 0 0 0<br> 8 9 1 0 0 0 0<br> 9 21 1 0 0 0 0<br> 10 22 1 0 0 0 0<br> 10 23 1 0 0 0 0<br> 10 24 1 0 0 0 0<br> 11 25 1 0 0 0 0<br> 11 26 1 0 0 0 0<br> 11 27 1 0 0 0 0<br> 12 28 1 0 0 0 0<br> 12 29 1 0 0 0 0<br> 12 30 1 0 0 0 0<br> 13 15 2 0 0 0 0<br> 13 16 1 0 0 0 0<br> 14 31 1 0 0 0 0<br> 15 18 1 0 0 0 0<br> 15 32 1 0 0 0 0<br> 16 19 2 0 0 0 0<br> 16 33 1 0 0 0 0<br> 17 34 1 0 0 0 0<br> 18 20 2 0 0 0 0<br> 18 35 1 0 0 0 0<br> 19 20 1 0 0 0 0<br> 19 36 1 0 0 0 0<br>M END
Compound Name
Triadimefon
CID
39385
Molecular Formula
C14H16ClN3O2
Molecular Weight
293
No. Hydrogen Bond Acceptors
4
Similar Applications
Reversed Phase
Pesticide panel using Kinetex 2.6u Polar C18 50x4.6mm
Kinetex 2.6 µm Polar C18 100 Å, LC Column 50 x 4.6 mm, Ea
24017
Reversed Phase
185 Pesticides on Kinetex Biphenyl 5u
Kinetex 5 µm Biphenyl 100 Å, LC Column 100 x 2.1 mm, Ea
22618
Chiral
Triadimefon on Lux 5µm Cellulose-4 in RP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21844
Chiral
Triadimefon on Lux 5µm Cellulose-2 in RP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21843
Chiral
Triadimefon on Lux 5µm Cellulose-2 in RP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21842
Chiral
Triadimefon on Lux 5µm Cellulose-1 in RP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21841
Chiral
Triadimefon on Lux 5µm Cellulose-2 in NP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21738
Chiral
Triadimefon on Lux 5µm Cellulose-1 in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21737
Application Specific
EPA Method 525.2 on ZB-SemiVolatiles
Zebron ZB-SemiVolatiles, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
21438
Standard
Nitrogen Pesticides - EPA Method 633 on ZB5ms 30x0.25x0.25
Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
15446
Standard
Nitrogen and Phosphorous Pesticides - EPA Method 507 on ZB-5MS
Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
15445
Standard
Nitrogen and Phosphorous Pesticides on ZB-5MS
Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
15439
Standard
EPA Method 525.2: Organic compounds in Drinking Water on ZB-5 on ZB-5
Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
14771