Pharma ABN Mixture using Kinetex 5u EVO C18 150x4.6mm
LC Conditions
Column
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
Brand
Kinetex
Part No
00F-4633-E0
Phase Name
EVO C18
Elution Type
Gradient
Mobile Phase
A: Water with 0.1% Formic acid
B: Acetonitrile with 0.1% Formci acid
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
95
5
2
10
5
95
3
10.1
95
5
4
15
95
5
Flow Rate
1.50 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Order Items Used in This Application
- 1. Uracil
- 2. Pindolol
- 3. Chlorpheniramine
- 4. Nortriptyline
- 5. 3-Methyl-4-Nitrobenzoic acid
- 6. 5-Methyl Salicyl Aldehyde
- 7. Hexanophenone
-OEChem-06211003142D<br><br> 12 12 0 0 0 0 0 0 0999 V2000<br> 2.0000 -0.6900 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -0.6900 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.6900 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 0.8100 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -0.1900 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -0.1900 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.3100 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 0.8100 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.3100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 1.1200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 1.1200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.9300 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 5 2 0 0 0 0<br> 2 6 2 0 0 0 0<br> 3 5 1 0 0 0 0<br> 3 6 1 0 0 0 0<br> 3 9 1 0 0 0 0<br> 4 5 1 0 0 0 0<br> 4 7 1 0 0 0 0<br> 4 10 1 0 0 0 0<br> 6 8 1 0 0 0 0<br> 7 8 2 0 0 0 0<br> 7 12 1 0 0 0 0<br> 8 11 1 0 0 0 0<br>M END
Compound Name
Uracil
CID
1174
Molecular Formula
C4H4N2O2
Molecular Weight
112
No. Hydrogen Bond Acceptors
2
No. Hydrogen Bond Donors
2
Similar Applications
Hydrophilic Interaction
HILIC Separation of Nucleobases using a Diol HILIC column
Luna Omega 3µm HILIC 100Å, LC Column 150 x 4.6 mm, ea
28694
Reversed Phase
ABN7 on Luna Omega 1.6u PS C18 50x2.1mm
Luna Omega 1.6µm PS C18 100Å, LC Column 50 x 2.1 mm, EA
23707
Reversed Phase
Batch Reproducibility with ABN 7 mix- Kinetex 2.6u F5 50x4.6mm
Kinetex 2.6 µm F5 100 Å, LC Column 50 x 4.6 mm, Ea
22803
Reversed Phase
Batch reproducibility of Kinetex 5u EVO C18 150x4.6mm
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
22734
Reversed Phase
Pharma ABN Mixture using Kinetex 5u EVO C18 150x4.6mm
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
22718
Reversed Phase
Aeris Batch Reproducalbity #3: SRM 870 on Aeris PEPTIDE 1.7u XB-C18 50x4.6mm
Aeris 1.7 µm PEPTIDE XB-C18 100 Å, LC Column 50 x 2.1 mm, Ea
19909
Reversed Phase
Aeris WIDEPORE 3.6u XB-C18 150 x 2.1mm ID QC Chromatogram (AL0-8931)
Aeris 3.6 µm WIDEPORE XB-C18 200 Å, LC Column 150 x 2.1 mm, Ea
19812
Reversed Phase
Aeris 3.6u XB-C8 150 x 2.1mm ID QC Chromatogram (AL0-8931)
Aeris 3.6 µm WIDEPORE XB-C8 200 Å, LC Column 150 x 2.1 mm, Ea
19811
Reversed Phase
Aeris 3.6u C4 150 x 2.1mm ID QC Chromatogram (AL0-8931)
Aeris 3.6 µm WIDEPORE C4 200 Å, LC Column 150 x 2.1 mm, Ea
19810
Reversed Phase
SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm With KrudKatcher
Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea
18803
Reversed Phase
SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm With Cartridge
Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea
18802
Reversed Phase
SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm Without Cartridge
Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea
18801