Aqueous Stablity Kinetex 2.6u F5 100x4.6mm (Organic Acids)

Aqueous Stablity Kinetex 2.6u F5 100x4.6mm (Organic Acids)
LC Conditions
Column

Kinetex 2.6 µm F5 100 Å, LC Column 100 x 4.6 mm, Ea

Brand

Kinetex

Part No

00D-4723-E0

Phase Name

F5

Elution Type

Isocratic

Mobile Phase

A: 20mM Potassium Phosphate pH 2.9

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

100

0

Flow Rate

1.50 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info

Order Items Used in This Application

Kinetex 2.6 µm F5 100 Å, LC Column 100 x 4.6 mm, Ea
00D-4723-E0

Kinetex 2.6 µm F5 100 Å, LC Column 100 x 4.6 mm, Ea

View Product

  • 1. Tartaric Acid
  • 2. Malic Acid
  • 3. Maleic Acid
  • 4. Fumaric Acid
  • 5. Succinic Acid
-OEChem-06211003142D<br><br> 16 15  0     1  0  0  0  0  0999 V2000<br>    4.2690   -1.2500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350    1.2500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.5369   -0.2500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.8671    0.2500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4030    1.2500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0010   -1.2500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -0.2500    0.0000 C   0  0  3  0  0  0  0  0  0  0  0  0<br>    5.1350    0.2500    0.0000 C   0  0  3  0  0  0  0  0  0  0  0  0<br>    3.4030    0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0010   -0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.0051   -0.6750    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.8711    0.6750    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -1.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.6720    1.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    0.0600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.4040   -0.0600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  7  1  0  0  0  0<br>  1 13  1  0  0  0  0<br>  2  8  1  0  0  0  0<br>  2 14  1  0  0  0  0<br>  3  9  1  0  0  0  0<br>  3 15  1  0  0  0  0<br>  4 10  1  0  0  0  0<br>  4 16  1  0  0  0  0<br>  5  9  2  0  0  0  0<br>  6 10  2  0  0  0  0<br>  7  8  1  0  0  0  0<br>  7  9  1  0  0  0  0<br>  7 11  1  0  0  0  0<br>  8 10  1  0  0  0  0<br>  8 12  1  0  0  0  0<br>M  END
Compound Name

Tartaric Acid

CID

875

Molecular Formula

C4H6O6

Molecular Weight

150

No. Hydrogen Bond Acceptors

6

No. Hydrogen Bond Donors

4

Similar Applications

Reversed Phase

Aqueous Stablity Kinetex 2.6u F5 100x4.6mm (Organic Acids)

Kinetex 2.6 µm F5 100 Å, LC Column 100 x 4.6 mm, Ea

22806

Ion Exclusion

SecurityGuard Comparisons on Rezex ROA 300 x 7.8mm With KrudKatcher

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

18812

Ion Exclusion

SecurityGuard Comparisons on Rezex ROA 300 x 7.8mm With Cartridge

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

18811

Ion Exclusion

SecurityGuard Comparisons on Rezex ROA 300 x 7.8mm Without Cartridge

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

18810

Ion Exclusion

Organic acids in wine using Rezex ROA

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

14971

Ion Exclusion

White wine using Rezex ROA

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

14970

Ion Exclusion

Monosaccharides with organic acids using Rezex ROA

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

14969

Ion Exclusion

Aliphatic acids using Rezex ROA

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

14962

Ion Exclusion

Organic Acid Std. (AL0-3039)

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

14749

Reversed Phase

Organic acids on Synergi Hydro-RP

Synergi 4 µm Hydro-RP 80 Å, LC Column 250 x 4.6 mm, Ea

14270

Ion Exclusion

Organic Acids

Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea

5515