Aqueous Stablity Kinetex 2.6u F5 100x4.6mm (Organic Acids)
LC Conditions
Column
Kinetex 2.6 µm F5 100 Å, LC Column 100 x 4.6 mm, Ea
Brand
Kinetex
Part No
00D-4723-E0
Phase Name
F5
Elution Type
Isocratic
Mobile Phase
A: 20mM Potassium Phosphate pH 2.9
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
1.50 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Order Items Used in This Application
- 1. Tartaric Acid
- 2. Malic Acid
- 3. Maleic Acid
- 4. Fumaric Acid
- 5. Succinic Acid
-OEChem-06211003142D<br><br> 16 15 0 1 0 0 0 0 0999 V2000<br> 4.2690 -1.2500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 1.2500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5369 -0.2500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8671 0.2500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 1.2500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 -1.2500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -0.2500 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 5.1350 0.2500 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 3.4030 0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 -0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.0051 -0.6750 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.8711 0.6750 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6720 1.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 0.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.4040 -0.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 7 1 0 0 0 0<br> 1 13 1 0 0 0 0<br> 2 8 1 0 0 0 0<br> 2 14 1 0 0 0 0<br> 3 9 1 0 0 0 0<br> 3 15 1 0 0 0 0<br> 4 10 1 0 0 0 0<br> 4 16 1 0 0 0 0<br> 5 9 2 0 0 0 0<br> 6 10 2 0 0 0 0<br> 7 8 1 0 0 0 0<br> 7 9 1 0 0 0 0<br> 7 11 1 0 0 0 0<br> 8 10 1 0 0 0 0<br> 8 12 1 0 0 0 0<br>M END
Compound Name
Tartaric Acid
CID
875
Molecular Formula
C4H6O6
Molecular Weight
150
No. Hydrogen Bond Acceptors
6
No. Hydrogen Bond Donors
4
Similar Applications
Reversed Phase
Aqueous Stablity Kinetex 2.6u F5 100x4.6mm (Organic Acids)
Kinetex 2.6 µm F5 100 Å, LC Column 100 x 4.6 mm, Ea
22806
Ion Exclusion
SecurityGuard Comparisons on Rezex ROA 300 x 7.8mm With KrudKatcher
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
18812
Ion Exclusion
SecurityGuard Comparisons on Rezex ROA 300 x 7.8mm With Cartridge
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
18811
Ion Exclusion
SecurityGuard Comparisons on Rezex ROA 300 x 7.8mm Without Cartridge
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
18810
Ion Exclusion
Organic acids in wine using Rezex ROA
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
14971
Ion Exclusion
White wine using Rezex ROA
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
14970
Ion Exclusion
Monosaccharides with organic acids using Rezex ROA
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
14969
Ion Exclusion
Aliphatic acids using Rezex ROA
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
14962
Ion Exclusion
Organic Acid Std. (AL0-3039)
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
14749
Reversed Phase
Organic acids on Synergi Hydro-RP
Synergi 4 µm Hydro-RP 80 Å, LC Column 250 x 4.6 mm, Ea
14270
Ion Exclusion
Organic Acids
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
5515