Ascorbic Acid by HPLC Standard
LC Conditions
Column
Synergi 4 µm Hydro-RP 80 Å, LC Column 150 x 4.6 mm, Ea
Brand
Synergi
Part No
00F-4375-E0
Phase Name
Hydro-RP
Elution Type
Isocratic
Mobile Phase
A: 0.1% H3PO4 in Water
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
1.00 mL/min
Temperature
25°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Order Items Used in This Application
- 1. Ascorbic Acid
-OEChem-06211003152D<br><br> 20 20 0 1 0 0 0 0 0999 V2000<br> 5.0929 0.3665 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5896 -0.5814 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.1738 1.3749 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0051 -1.9814 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.1807 -1.9814 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8530 0.0877 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2839 -0.2213 0.0000 C 0 0 2 0 0 0 0 0 0 0 0 0<br> 3.3328 0.0877 0.0000 C 0 0 2 0 0 0 0 0 0 0 0 0<br> 4.5929 -1.1723 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1249 1.0659 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5929 -1.1723 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.9019 -0.2213 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.1509 0.6183 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4617 -0.5187 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7445 1.0875 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.2112 1.6798 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.3898 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0449 1.9814 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7973 -1.9166 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.9818 0.6942 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 7 1 0 0 0 0<br> 1 12 1 0 0 0 0<br> 8 2 1 1 0 0 0<br> 2 17 1 0 0 0 0<br> 3 10 1 0 0 0 0<br> 3 18 1 0 0 0 0<br> 4 9 2 0 0 0 0<br> 5 11 1 0 0 0 0<br> 5 19 1 0 0 0 0<br> 6 12 1 0 0 0 0<br> 6 20 1 0 0 0 0<br> 7 8 1 0 0 0 0<br> 7 9 1 0 0 0 0<br> 7 13 1 6 0 0 0<br> 8 10 1 0 0 0 0<br> 8 14 1 0 0 0 0<br> 9 11 1 0 0 0 0<br> 10 15 1 0 0 0 0<br> 10 16 1 0 0 0 0<br> 11 12 2 0 0 0 0<br>M END
Compound Name
Ascorbic Acid
CID
5785
Molecular Formula
C6H8O6
Molecular Weight
176
No. Hydrogen Bond Acceptors
6
No. Hydrogen Bond Donors
4
Similar Applications
Reversed Phase
HPLC Separation of Common Organic Acids in Food and Beverages on Luna Omega 3u 250x4.6mm; Wine panel
Luna Omega 3 µm Polar C18 100 Å, LC Column 250 x 4.6 mm, Ea
26858
Reversed Phase
Water-soluble Vitamins on Kinetex 2.6u, C18, 75x4.6 by HPLC (#20715)
Kinetex 2.6 µm C18 100 Å, LC Column 75 x 4.6 mm, Ea
20908
Reversed Phase
Water-soluble Vitamins on Kinetex 2.6u, C18, 150x4.6 by HPLC (#20715)
Kinetex 2.6 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
20907
Reversed Phase
Water soluble vitamins on Kinetex 2.6µm C18, 100x4.6mm
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea
20596
Reversed Phase
Water-soluble Vitamins on Kinetex 2.6u, C18, 75x4.6 by HPLC
Kinetex 2.6 µm C18 100 Å, LC Column 75 x 4.6 mm, Ea
20001
Reversed Phase
Water-soluble Vitamins on Kinetex 2.6u, C18, 150x4.6 by HPLC
Kinetex 2.6 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
20000
Hydrophilic Interaction
Water-soluble vitamins on Kinetex 2.6um HILIC 150 x 4.6mm
Kinetex 2.6 µm HILIC 100 Å, LC Column 150 x 4.6 mm, Ea
18842
Reversed Phase
Artificial sweeteners
Prodigy 5 µm ODS-3 100 Å, LC Column 150 x 4.6 mm, Ea
13339
Reversed Phase
Soft Drink Additives
Synergi 4 µm Polar-RP 80 Å, LC Column 250 x 4.6 mm, Ea
13010